3.3 ELECTRIC CONNECTIONS
3.3 ELECTRICAL CONNECTIONS
3.3.1 RADIO VERSION
3.3.2 WIND VERSION
a
220 V ~
220 V ~
a
b
YELLOW-GREEN
BLUE
BROWN
PHASE
NEUTRAL WIRE
PUSH-BUTTON
AUTOMATED SYSTEM CONTROLLED BY REMOTE CONTROL
ONLY:
For this type of configuration, connect the blue and
brown cables of the motor to the mains power supply and
the yellow-green cable to earth.
Do not connect the RED
(or black) wire.
Do not cut the red (or black) cable if it is not
used, just insulate it
AUTOMATED SYSTEM CONTROLLED BOTH BY REMOTE
CONTROL AND BY PUSH-BUTTON:
For this type of
configuration, connect the motor as shown in the previous
diagram, fig. 6.
The push-button has a step-by-step logic:
each pressure exerted on the push-button
sends a pulse to the motor (I.E.: FIRST PULSE UP
- SECOND PULSE STOP - THIRD PULSE DOWN etc.).
After a down or up command, the motor stays
active until the relevant travel limit has been
reached.
The series R tubular motor can be controlled both by the
remote control and by a push-button with step-by-step
logic.
The series W tubular motor can be controlled both by the
remote control and by a push-button with step-by-step
logic. In addition, a wind sensor (anemometer) can be
connected to the motor: it commands the
closure of the
rolling shutter
as soon as the wind has reached a speed
higher than 20 Km/h.
WHEN THE ANEMOMETER OPERATES, THE MOTOR
DIRECTION OF ROTATION CORRESPONDS TO THAT
CONTROLLED BY THE UP PUSH-BUTTON OF THE
REMOTE CONTROL. THE DOWN COMMAND IS
INHIBITED FOR 16 min.
AUTOMATED SYSTEM CONTROLLED BY REMOTE CONTROL
AND ANEMOMETER:
For this type of configuration, connect
the blue and the brown wire of the motor to the mains
power, and the yellow-green wire to earth. Do not connect
the red (or black) wire.
THE ANEMOMETER must be connected as shown in figure 7.
AUTOMATED SYSTEM CONTROLLED BY REMOTE CONTROL,
PUSH-BUTTON AND ANEMOMETER:
For this type of
configuration, connect the motor as shown in the diagram
of figure 7.
Fig.6
Fig.7
YELLOW-GREEN
BLUE
BROWN
RED
(OR BLACK)
PUSH-BUTTON
WHITE
ANEMOMETER
The push-button has a step-by-step logic:
each pressure exerted on the push-button
sends a pulse to the motor (I.E.: FIRST PULSE UP
- SECOND PULSE STOP - THIRD PULSE DOWN -etc.).
After a down or up command, the motor stays
active until the relevant travel limit has been
reached.
Do not cut the red (or black) cable if it is not
used
.
RED
OR BLACK
PHASE
NEUTRAL WIRE