background image

ENGLISH

5

3.3  ELECTRIC CONNECTIONS

3.3  ELECTRICAL CONNECTIONS

3.3.1  RADIO VERSION

3.3.2  WIND VERSION

a

220 V ~

220 V ~

a

b

YELLOW-GREEN

BLUE

BROWN

PHASE

NEUTRAL WIRE

PUSH-BUTTON

AUTOMATED SYSTEM CONTROLLED BY REMOTE CONTROL 

ONLY:

 For this type of configuration, connect the blue and 

brown cables of the motor to the mains power supply and 

the yellow-green cable to earth. 

Do not connect the RED 

(or black) wire.

   Do not cut the red (or black) cable if it is not 

used, just insulate it

AUTOMATED SYSTEM CONTROLLED BOTH BY REMOTE 

CONTROL AND BY PUSH-BUTTON:

  For  this  type  of 

configuration, connect the motor as shown in the previous 

diagram, fig. 6.

  

The push-button has a step-by-step logic: 

each pressure exerted on the push-button 
sends a pulse to the motor (I.E.: FIRST PULSE UP 
- SECOND PULSE STOP - THIRD PULSE DOWN etc.). 
After a down or up command, the motor stays 
active until the relevant travel limit has been 
reached.

The series R tubular motor can be controlled both by the 

remote  control  and  by  a  push-button  with  step-by-step 

logic.

The series W tubular motor can be controlled both by the 

remote  control  and  by  a  push-button  with  step-by-step 

logic. In addition, a wind sensor (anemometer) can be 

connected to the motor: it commands the 

closure of the 

rolling shutter 

as soon as the wind has reached a speed 

higher than 20 Km/h. 

  

WHEN THE ANEMOMETER OPERATES, THE MOTOR 

DIRECTION OF ROTATION CORRESPONDS TO THAT 
CONTROLLED BY THE UP PUSH-BUTTON OF THE 
REMOTE CONTROL.      THE DOWN COMMAND IS 
INHIBITED FOR 16 min.

AUTOMATED SYSTEM CONTROLLED BY REMOTE CONTROL 

AND ANEMOMETER:

 For this type of configuration, connect 

the blue and the brown wire of the motor to the mains 

power, and the yellow-green wire to earth. Do not connect 

the red (or black) wire.

THE ANEMOMETER must be connected as shown in figure 7. 

AUTOMATED SYSTEM CONTROLLED BY REMOTE CONTROL, 

PUSH-BUTTON AND ANEMOMETER:

  For  this  type  of 

configuration, connect the motor as shown in the diagram 

of figure 7.

Fig.6

Fig.7

YELLOW-GREEN

BLUE

BROWN

RED

(OR BLACK)

PUSH-BUTTON

WHITE

ANEMOMETER

  

The push-button has a step-by-step logic: 

each pressure exerted on the push-button 
sends a pulse to the motor (I.E.: FIRST PULSE UP 
- SECOND PULSE STOP - THIRD PULSE DOWN -etc.). 
After a down or up command, the motor stays 
active until the relevant travel limit has been 
reached.

   Do not cut the red (or black) cable if it is not 

used

.

RED

OR BLACK

PHASE

NEUTRAL WIRE

Summary of Contents for T-MODE TM R Series

Page 1: ...T MODE TM R W 433 Mhz...

Page 2: ...force 7 The power mains of the automated system must be fitted with a multi pole power switch with a switch contact gap of at least 3 mm 8 The min installation height for the automated system is 2 5 m...

Page 3: ...16 45 570 IP44 15 17 15 20 4 17 230 50 180 0 8 16 45 670 IP44 25 17 20 20 4 17 230 50 250 1 1 16 45 670 IP44 30 17 30 20 4 17 230 50 250 1 1 28 45 670 IP44 35 12 35 20 4 12 230 50 250 1 1 28 45 670 IP...

Page 4: ...h a drill 3 mm on the roller Fig 3 ref b at the distance A previously measured on the tubular motor Fig 3 ref a 3 Fit the assembled tubular motor inside the roller from the side opposite the cap until...

Page 5: ...control and by a push button with step by step logic In addition a wind sensor anemometer can be connected to the motor it commands the closure of the rolling shutter as soon as the wind has reached a...

Page 6: ...hs 1 Supply the motor with power 2 Within 15 seconds press the P programming push button then the DOWN push button of the transmitter 3 The motor performs two brief movements in both directions to con...

Page 7: ...HER REMOTE CONTROLS 433Mhz 1 Supply power to the motor 2 On an already memory stored remote control press the PROGRAMMING push button for 2 seconds and within 5 seconds press the STOP push button 3 On...

Page 8: ...out making the connection 2 Supply power to the motor after approx 10 seconds the motor operates in both directions for 1 second signalling that the memory has been completely deleted 3 Cut power agai...

Page 9: ...the adjustment tool turn the screw of the travel limit stop corresponding to the roller s rise rotation direction Fig 12 ref a toward the plus sign to increase the travel of the roller shutter or towa...

Page 10: ...mebush Sydney Australia tel 61 2 87565644 www faac com au INDIA FAAC INDIA PVT LTD Noida Delhi India tel 91 120 3934100 4199 www faacindia com SWITZERLAND FAAC AG Altdorf Switzerland tel 41 41 8713440...