11
5.
Tighten the bolt.
The mechanical stop is coupled to a toothed section on the
operator's body, Fig. 19 Ref. 2. In case of difficulties moving the
stop check that the coupling is free.
Do not force it.
2.5.2 Mechanical Stop at Closing
1.
Disengage the operator’s manual release (see Par. 3)
4.
Move the mechanical stop until it is close to the back
side of the bracket, as indicated in Figure 20.
2.
Manually move the leaf into its closing position.
3.
Loosen the bolt, Fig. 21 ref. 1. The bolt does not need
to be completely removed.
4.
Move the mechanical stop until it is close to the front
side of the bracket, as indicated in Fig. 22.
5.
Tighten the bolt.
The mechanical stop is coupled to a toothed section on the
operator's body, Fig. 21 Ref. 2. In case of difficulties moving
the stop check that the coupling is free.
Do not force it.
If the gate system needs to be moved manually due to power
outage or an operator malfunction, proceed as follows
:
1.
Turn power off at the main breaker and disconnect
the backup battery if present.
2.
Slide off the protective cap, Fig. 23 Ref. 1.
3.
Insert the supplied release key, Fig. 23 Ref. 2, and turn
it counter-clockwise until it stops, Fig. 23 Ref. 3. The
release position is indicated by an open padlock.
4.
Move the leaf manually.
NOTE: To keep the operator in manual mode the release
device should be left in its current (unlocked) position
and main power should be kept off
3. MANUAL OPERATION
Fig. 19
Fig. 20
Fig. 21
Fig. 22