![background image](http://html1.mh-extra.com/html/faac/jcall/jcall_quick-installers-manual_3120008004.webp)
CONTROL FUNCTIONS RESERVED FOR NORMAL USERS
SYNTAX
Timed activation of the output associated with the group to which he/she
belongs.
OPEN
WARNING:
the relay codes 0-9 to use in the SMS commands or in programming using the Jcall Manager software correspond to
terminals OUT1-OUT10 on the board according to the following table:
Relay code
Board terminal
0 OUT1
1 OUT2
2 OUT3
3 OUT4
4 OUT5
5 OUT6
6 OUT7
7 OUT8
8 OUT9
9 OUT10
10.
Programming using the Jcall Manager management software
The Jcall Manager software allows Jcall to be programmed entirely via a PC and can be downloaded from the download area at
the following web address:
http://jcallwebmanager.faacgroup.com
Jcall Manager allows you to:
•
enter, delete and modify users
•
enter, delete and modify groups of users (e.g. time bands enabled for access)
•
modify the settings of the Jcall board
•
display the access log
•
access the board diagnostics functions
To program the board, it must be connected to the PC using a Mini USB type B cable (not included).
11.
Programming via the Internet: Jcall WebManager
The Jcall WebManager platform allows the Jcall control unit to be programmed and monitored remotely via the Internet using the
GPRS connection without the need for cables.
For further information on the Jcall WebManager platform, please contact your local FAAC sales representative.
12.
Technical data
Jcall board
Operating temperature
from -30°C to +70°C
Power supply
12V DC
Average current consumption
minimum: 90 mA, maximum: 300 mA
Output port for programming and monitoring via PC
Mini-USB type B serial port
Number of main board inputs/outputs
4 digital inputs, 2 relay outputs
Maximum number of outputs using the expansion card
Up to 10 relay outputs
Frequency band
Quad-band GSM 850/900/1800/1900MHz
Board dimensions
136 mm x 108 mm x 30 mm
Board weight, approx.
100g
maximum OUT terminal voltage
24 VAC/VDC
maximum OUT terminal current
1 A
Peripheral power supply voltages available
5V, 12V
Maximum available peripheral power supply current
240mA@12V, 500mA@5V
Power supply
Input voltage
88-264VAC / 47-63Hz
Input current
400mA@230VAC
Output voltage
12V DC
Output current
2.1 A
Use Internal
Power supply type
Stabilised switching
Power supply dimensions
78x51x28 mm
Power supply weight, approx.
200g
GSM Antenna
Connector SMA,
UFL
SMA antenna cable length
3m
SMA antenna fastening
Magnetic
SMA antenna height
7 cm
For further information, please see the download area at
http://jcallwebmanager.faacgroup.com
and/or contact your local FAAC
sales representative.