G  

 
 

Summary of Contents for FAA-4300

Page 1: ... Headquarter East Coast Operations 3160 Murrell Rd Rockledge FL 32955 Tel 800 221 8278 www faacusa com FAAC International Inc West Coast Operations 357 South Acacia Avenue Fullerton CA 92831 DO NOT GIVE TO HOME OWNER FOR PROFESSIONAL USE ONLY 3G ...

Page 2: ... up and LEDS Installing the programmer APP for the first time Programming a brand new install Programming an existing install Programming main steps Additional Features Keypad codes Prox cards optional models only Auto opening closing App control of gates Do not disturb After hours calling Programming codes Ringing times Volumes Information Relay times Complete list of parameters Troubleshooting 3...

Page 3: ...he gate door of the install site BEFORE installing this product Set up on a bench in workshop BEFORE going to site Program the unit in the comfort of your work bench and call technical support should you have questions Manufacturer warranty does NOT cover lighting storm damage You MUST fit external surge protection and lightning rod in order to maintain warranty on this product Evidence of surge p...

Page 4: ...all button Push button Speaker grill Cellular PCB Optional Prox Coil Optional Keypad module Optional Keypad Optional Prox reader module Surge Power Conditionin g Module Hinged front door Microphone Built in antenna Security screw access Optional Prox badge reader ...

Page 5: ...oseneck re fit the module and connect a 14 gauge earth wire to the earth terminal 2 Earth Rod close as possible Maintain manufacturer s warranty by adhering to the guidelines shown Use 110v surge protected supply Surge protected 110v 4 24v dc PSU 16 gauge MIN 30 feet MAX Call box Remove 4 screws and remove power conditioning module if needed ...

Page 6: ...s 3Ah 12v dc max Power Module in Detail Earth Rod Connection Gate Position Limit switch optional 1A quick blow input fuse Exit Button To Call Button pre wired 12v dc 100mA button illumination 24v dc IN pre wired CPU Status Signal Status Power Cellular Module in Detail SIM holder Antenna connection Relay 1 N O COM N C N O COM N C ...

Page 7: ... PROX Modules in Detail Slave OUT connections Wiring Relays Electric Gates 24v out GND Note The manufacturer is not responsible for wiring to third party devices Please consult an experienced security installer Pedestrian gates or door Magnetic lock Exit button Separate lock Power supply not supplied Start Common COM N O N C COM ...

Page 8: ...ve while power on To next device Optional Keypad Optional Prox reader Optional Slave Keypad Optional Slave Prox Reader CAT5 30ft max 300ft if device powered separately To next device 45 chamfer OUT Pads DOWN Ensure SIM is activated Pre pay SIM will need credit first At T preferred T Mobile also compatible in certain areas Connecting Slave Devices ...

Page 9: ...P for the first time If you are using an Apple or Android smart phone download and install the FAAC Cell Access Pro APP It will make programming much easier Note You may notice the app Cell Access on the store This is for homeowners to use CPU Flashing standby Constant ON OFF busy SIGNAL STRENGTH 1 flash poor 1 bar 2 flashes low 2 bars 3 flashes good 3 bars 4 flashes Strong 4 bars 5 flashes search...

Page 10: ...10 Accept and allow all permissions Android version shown After you send the registration email go back to the app screen To register first time enter your name email and cell phone number ...

Page 11: ...amming an EXISTING Install Enter site or customer name and INTERCOM PHONE NUMBER If Engineers and user pass codes are at default then do not change these Once completed you are ready to begin programming Now you are ready to begin programming ...

Page 12: ...m On iphone users will be taken to their SMS screen to confirm before sending the string The intercom should reply with a signal level between 1 31 1 12 Poor 13 20 Medium 21 31 Good For good performance signal level should be at least 13 or better TIP If signal is lower than recommended then take IMMEDIATE action Change network if possible or use an optional high gain antenna Check power cable is ...

Page 13: ...in the intercom Step 3 Activate Daily Activity This feature is needed for 2 reasons 1 To prevent some cellular carriers disconnecting the 4G LTE due to inactivity on the device 2 To keep time synchronisation in regions where there are summer daylight saving time changes 9999 87 Pass code Function code 1 99 days 00 no SMS sheduling It is recommended to set the number of days to 01 which will send S...

Page 14: ...9 73telephonenumber To delete all numbers 9999 73 Step4 Programming Numbers for the intercom to call 1 Press the SINGLE home icon for a 1 button system or MULTI for a 10 button system 2 Simply enter cell phone numbers and or landline phones which the intercom is to call when the call button is pressed 10 button model please enter button number 3 Press SAVE Note iphone users will be taken to their ...

Page 15: ...lon E g 8 30am 0830 Enter end time in 24hr format military style with no colon E g 1 30pm 1330 Select the days which access are to be granted SMS string for time restricted caller ID 9999 72 day day day time1 time2 number Pass code Function code Enter start and end time in 24hr 4 digit format no colon and separate with comma e g 0800 2300 Select days up to 7 3 digit format separate with commas e g...

Page 16: ...stricted Code Stores up to 20 codes which can be restricted to pre set times and days of the week Relay 1 only Enter a 4 digit code Enter start time in 24hr format military style with no colon E g 8 30am 0830 Enter end time in 24hr format military style with no colon E g 1 30pm 1330 Select the days which access are to be granted SMS String for adding keypad codes 9999 83 day day day time1 time2 co...

Page 17: ...rk during pre set times and days of the week Temporary Prox cards which auto expire in a pre se time Check stored Prox cards Intercom will reply with SMS message Temporary Code Stores up to 30 codes which will auto expire after the pre set time has elapsed Enter a 4 digit code Enter time in hrs 1 168 SMS String for temporary code 9999 82 hours code Pass code Function code Can be between 1 168 hour...

Page 18: ...ays and times of the week Relay 1 only Enter start time in 24hr format military style with no colon E g 8 30am 0830 Enter end time in 24hr format military style with no colon E g 1 30pm 1330 Select the days which access are to be granted Enter card ID 10 digits SMS String for time restricted card tag 9999 63 day day day time1 time2 cardID Pass code Function code Enter start and end time in 24hr 4 ...

Page 19: ...ID to be deleted Deleting ALL cards 9999 64 Enter known card ID 10 digits xxxxxxxx Delete all stored cards and start again Auto Expiring Temp Cards Store up to 30 cards which auto expire within a certain time frame Relay 1 only SMS String for temporary card tag 9999 62 hours cardID Pass code Function code Can be between 1 168 hours Card ID Enter card ID 10 digits Enter countdown time in hours 1 16...

Page 20: ...closing gates use latching and unlatching commands to control open times 1234 1 day day day time USER passcode Command 1 trigger relay 1 2 latch relay 1 3 unlatch relay 1 4 trigger relay 2 5 latch relay 2 6 unlatch relay 2 Enter time in 24hr format no colon Select days up to 7 3 digit format separate with commas E g mon tue wed thu fri 1 Pick the event 2 Enter time in 24hr format no colon 3 Select...

Page 21: ...y button press outside of these times will be ignored by the intercom Quick enable disable button Set start and end time for button active times 24hr format no colon E g 8 30am 0830 Set the days in which calls should be received and do not select days which calls should be ignored 9999 21 day day day time1 time2 Pass code Function code Enter start and end time in 24hr 4 digit format no colon and s...

Page 22: ...position 1 4 Programming codes There are 2 main SMS programming pass codes on the intercom One for the installer default 9999 and the other for the user homeowner default 1234 It is advised to change these from the defaults in order to help maintain property security Note user and programmer code cannot be the same as each other If changing default codes then you will now need to update the client...

Page 23: ...umber 9999 46XX X dialling time for second number 9999 47XX X dialling time for third number 9999 53XX X talking time in seconds 9999 max Volumes Adjust microphone and speaker volumes 1 9 default 5 If your customer experiences high levels of echo on their phone when speaking to the gate try reducing the microphone sensitivity as much as possible and also reduce the speaker volume if possible SMS s...

Page 24: ...ent 22 Open Relay1 on Relay2 off open refers to state of the status input connection in the intercom Relay 1 and 2 will show ON if latched 1234 26 NORM xxxx PLAN xxxxx TEMP xxxxx 1234 25 NORM xxxx PLAN xxxxx TEMP xxxxx NORM 24 7 cards PLAN time restricted cards TEMP Temporary cards NORM 24 7 codes PLAN time restricted codes TEMP Temporary codes 23 0930 05 01 19 code XX34 Last 20 events are listed ...

Page 25: ... out numbers 9999 1XY Store dialling out numbers X button number 1 9 0 for button 10 Y number dialled 1 4 phone number N A 9999 1XY Delete a dial out number X button number Y number position 1 4 N A Volume controls 9999 3 Speaker volume Where 1 9 1 lowest 9 highest 5 9999 4 Microphone volume Where 1 9 1 lowest 9 highest 5 Timings Relay Times Relay default trigger times are 1 second Use this featur...

Page 26: ...999 58 Choose between making a scheduled call or scheduled SMS 1 SMS 2 call 1 9999 77 Delete the stored service number N A Caller ID features 9999 72number Store caller ID number Max 14 digits Only last 6 digits compared N A 9999 73number Delete caller ID number N A 9999 73 Delete all caller ID numbers N A Service diagnostic messages no passcode required for some of these 20 Check reception level ...

Page 27: ...ect 9999 87 number of days between SMS calibration SMS should be sent 0 no message sending N A Do Not Disturb push button de activated during set times 1234 21 ON ON activated OFF de activated OFF 9999 21 day day day time1 time2 Enter all active days during which button should operate Enter start and end time button should operate 24 hr format no colon E G 8 30am 0830 N A Alternate Number to Call ...

Page 28: ...r time as per programming instructions Q The caller ID part does not work A Be sure to program the caller ID part under 72 feature If your number is a private or number withheld then it will not work Even if you have already programmed a number to receive a call from the intercom if you also want that number to have caller ID access it must be programmed under the 72 feature also Ensure the number...

Page 29: ...e power supply directly to the unit Q The system was operating the gates fine but now it will not trigger the gates Frequently this is cause by the user accidentally latching the relay This latches the output relay permanently on Send the intercom the following SMS 22 The intercom should reply with a message detailing the relay status If it has been latched then the message will state the relay is...

Page 30: ... product s or has been subject to misuse negligence or accident or has not been operated in accordance with FAAC International Inc s or FAAC S p A s instructions or has been operated under conditions more severe than or otherwise exceeding those set forth in the specifications for such product s Neither FAAC S p A nor FAAC International Inc shall be liable for any loss or damage whatsoever resulti...

Page 31: ...terference and 2 this device must accept any interference received including interference that may cause undesired operation Output power listed is ERP below 1GHz for Part 22 and EIRP above 1GHz for Part 24 RF exposure compliance is addressed for 1 1310 and 2 1091 MPE limits The antenna s used for this transmitter must be installed to provide a separation distance of at least 20 cm from all person...

Page 32: ...32 Note For legal reasons telephone technical support is for registered and qualified product dealers only Home owners and end users should contact their local dealer for product technical support ...

Reviews: