Setting Operating Parameters
Complete this step prior to programming the gate run time. This will
dictate how your gate will react during programming and normal op-
eration.
It is not necessary to reset these if power is removed or if reset is
tripped, they will stay set.
Entering programming mode
1. Make the necessary power connections and check the LED lights to be sure the appropriate
lights are lit.
2. The display should show
3. Press and hold down
P2
until the display shows parameter A with the
corresponding number that is currently default or previously pro-
grammed.
4. Press
P1
to change the number variable of the parameter,
USE THE
CHART ON THE NEXT PAGE AS A GUIDE.
5. To move to the next parameter, Press
P2
.
6. When 60 seconds have elapsed without any button being pressed the control unit automatical-
ly exits the programming mode. To exit manually, Press
P2
to scroll through all the parame-
ters until the display shows
Important Dip Switch Setting
Verify the 4 dipswitches to the left of the display LED are as follows:
5.1
1. DOWN
2. DOWN
3. UP
4. UP