DAAB COMMUNICATION CARD DB512 INSTRUCTION MANUAL
2
Revision 1
Technical data
Dimensions (WxHxD)
70 x 37 x 20 mm
Temperature range
0 to 50°C
Indications
6x LEDs
Degree of protection
The circuit board is intended for internal installation in an enclosure
Safety instructions
See operating manual for automatic control unit EP105.
General description
DB512 is an add-in card to obtain communication between two EP105s. Various interlocks and operating functions can be
programmed using the communication, see also “Example of use” on page 4. EP105 with DB512 connected can also be
linked to older EP104 automatic control units.
Indications
Communication status is indicated by six LEDs mounted on the card.
Rapid flashing LEDs D2 and D3 indicate that the card is sending and receiving information to and from the other card.
Unlit LED D6 indicates that the interlock function is selected.
Installation
1. Discharge any static charge in your body by touching an earthed connection before starting installation.
2. Disconnect power to EP105.
3. Fit the two red connectors together.
4. Screw the card into place using three M3x5 screws.
5. Connect the communication cable as described under
Connection
in this document.