INSTRUCTION MANUAL AUTOMATIC MAGNETIC LOCK DB310
Revision 9
3
Safety instructions
See instruction manual for automatic control units EP103/EP104/EP105.
General description
Add-in card that magnetises and demagnetises an electromagnet. Demagnetisation takes place for about
3 seconds on each start of both opening and closing movements of the gate.
The recommended power supply to the DB301 and magnet is FAAB's transformer SPD.
Installation
1.
Disconnect power to the automatic control unit and transformer.
2.
Attach DB310 to DIN rail.
3.
Connect the card as described in Connection.
Note that if the magnetic lock is of the overlap type, it is motor 1 that opens first.
Connection
Note that the connection of DB310 differs depending on version of EP card and software, see the
illustrations below. Connection must be performed by a qualified technician.
Suitable cable area between DB310 and the magnet is 0.75 mm
2
up to 50 m, there after 1.5 mm
2
up to a
maximum of 100 m. Supply between DB310 and the magnet must be done via a separate cable.
Example of connection for one magnetic lock:
Power Supply
24VDC
Automatic control
units:
EP103
or
EP104
with
software version
4.06 or lower
Magnetic lock control unit
DB310
0V
24V
7
EP
+
-
MA
GN
Lock magnet
Power supply
24VDC
Automatic control
units:
EP104
with
software version
4.07 or higher
EP105
Magnetic lock control unit
DB310
0V
24V
31
EP
+
-
MA
GN
Lock magnet
Summary of Contents for DAAB DB310