FAAC DAAB DB310 Instruction Manual Download Page 3

INSTRUCTION MANUAL AUTOMATIC MAGNETIC LOCK DB310

Revision 9 

3

Safety instructions

See instruction manual for automatic control units EP103/EP104/EP105.

General description

Add-in card that magnetises and demagnetises an electromagnet. Demagnetisation takes place for about 

3 seconds on each start of  both opening and closing movements of  the gate.

The recommended power supply to the DB301 and magnet is FAAB's transformer SPD. 

Installation

1. 

Disconnect power to the automatic control unit and transformer.

2. 

Attach DB310 to DIN rail.

3. 

Connect the card as described in Connection. 

Note that if  the magnetic lock is of  the overlap type, it is motor 1 that opens first.

Connection

Note that the connection of DB310 differs depending on version of  EP card and software, see the 

illustrations below. Connection must be performed by a qualified technician.

Suitable cable area between DB310 and the magnet is 0.75 mm

2

 up to 50 m, there after 1.5 mm

2  

up to a 

maximum of  100 m. Supply between DB310 and the magnet must be done via a separate cable.

Example of connection for one magnetic lock:

Power Supply

24VDC

Automatic control

units:

EP103

 or

EP104 

with

software version

4.06 or lower

Magnetic lock control unit

DB310

0V

24V

7

EP

+

-

MA

GN

Lock magnet

Power supply

24VDC

Automatic control

units:

EP104

 with

software version

4.07 or higher

EP105

Magnetic lock control unit

DB310

0V

24V

31

EP

+

-

MA

GN

Lock magnet

Reviews: