background image

DIP SWITCHES        ON              OFF         FACTORY SETTING

1   Sensitivity high      Sensitivity low (recommended         ON

for mounting height < 2,2 m)

2   Passive mode       Active mode               OFF
3   Hold time : 2 sec     Hold time : 0,5 sec            OFF

A .   M O U N T I N G   T H E   B F P 1

OPENING

AND

CLOSING

THE SENSOR

OPENING

AND

CLOSING

THE FSA

MOUNTING 

THE SENSOR

• Use a small screwdriver to open the sensor
• Insert the screwdriver in the rectangular hole under the bracket cam
• Use it as a lever upwards

• Consider the position of the guide pin when inserting both legs of the 

front cover to the base

• Gently push both sides of the front cover

• Insert the bottom of the front cover to the bottom clip of the base
• Push on the top of the front cover face

• Either use the screwdriver to open the FSA (left picture)
• Or pinch off both sides of the front cover (right picture)
• Rotate the front cover upwards

A . D I P   S W I T C H E S   S E T T I N G S   A N D   R E L A Y   C O N F I G U R A T I O N S

B . S E N S I N G   F I E L D   P O S I T I O N

ON

2

1

3

SETTING

OF

THE SENSOR

ACTIVE MODE

PASSIVE MODE

DETECTION

NO DETECTION

DESCRIPTION

OF 

THE PRODUCT 

AND

THE SENSOR

• Wiring

• Inner view of the sensor front cover

• Description of the product

• Description of the sensor

12-24 V AC/DC

COM

NO

NC

1

2

3

4

5

O P E N I N G   T H E

 

  F S A   A C C E S S O R Y

C L O S I N G   T H E

 

  F S A   A C C E S S O R Y

• The LED flashes for a few seconds when the sensor is switched on
• The LED lights up through the lens when the sensor detects motion

The relay configurations are :

LED 
SIGNAL

2,2 m

50 cm 50 cm 50 cm

1,5 m  depth

3 m

PROFILE VIEW

2,2 m

50 cm 50 cm 50 cm 50 cm 50 cm

2,5 m

2,5 m

height 2,2 m

door

threshold

3 m

1,5 m

FRONT VIEW

FLAT VIEW

• Stick the template on the wall
• Drill the 2 holes to fix the FSA 

and the hole for the cable

• Open the FSA (see page 2 : 

opening and closing the FSA 
Accessory)

• Cut the wire opening footprint 

of the base

• Fix the sensor to the FSA base 

with the 2 screws

• Connect the sensor to the cable
• Close the FSA (see page 2 : 

opening and closing the FSA 
Accessory)

Wire Opening Footprints

Main cable

Unplug 5-wire connector
2 screws to fix the BFP1
2 brackets
Lens
2 screws to fix the brackets with 

the BFP1

Masking Lens (2 units)

Microprocessor
LED
Dip Switches
PYRO element

Guide Pins of the BFP1 base

Guide pins of the BFP1 base

Guide pins of the masking lens

COM (3)

NO (4)

NC (5)

COM (3)

NO (4)

NC (5)

COM (3)

NO (4)

NC (5)

COM (3)

NO (4)

NC (5)

ACCESSORY