SYMPTOMS 

                       PROBABLE CAUSES              CORRECTIVE ACTIONS

The door will not open and the LED does not light up  The sensor is not properly powered        a. Check the power supply

b. Check the supplied voltage

The door will not open and the LED lights up       The wiring of the relay output is not        Check the relay wiring

connected correctly

The door opens when no detection occurs and closes   The mode of the relay output is          Change the dip-switch #2 position
during a detection                     not correct

The sensing field does not correspond to your      The cut of the masking lens is wrong       Cut out a new lens to meet the required
requirements 

sensing field size

TROUBLE-

SHOOTINGS

42

.00

06

/

V1

-12

.0

1

  

  

 7

3293

7

  

 Re

v. 

A

FAAC S.p.A.  -  Via Benini, 1  40069  Zola Predosa  -  Italia  - tel.+39 051 61724 - fax.+39 051 758518  -  www.faacgroup.com

C .   S E T T I N G   T H E   S E N S I N G   F I E L D  

• To adjust the sensing field according to your specific needs, use the masking delivered in the sensor box;

The minimum detection area at mounting height of 2.2 m is 0.5 m x 0.5 m

• To tailor the sensing field, cut segments

Remarks : 

1) Be careful to cut just entire segments
2) It is necessary to cut at least one segment to get a detection

To insert the masking lens :

• Consider the position of the guide pins when inserting both legs of the masking lens to the front cover
• Gently push both legs of the masking lens

To remove the masking lens :

• Insert the screwdriver between the leg of the masking lens and the leg of the front cover
• Use it as a lever downwards

ASYMMETRICAL SENSING FIELD SHORTER DEPTH

S E N S I N G   F I E L D

DETECTION AREA     DETECTION AREA

±10 cm

±10 cm

door threshold    door threshold

TECHNICAL
SPECIFICATIONS

THE MOST ADVANCED TECHNOLOGY IN PASSIVE INFRARED SENSOR RANGE

DESCRIPTION 

INSTALLATION
TIPS

The passive infrared 
sensor

FSA Accessory
for mounting on the wall

The 

BFP1 

is designed for use in opening of automatic doors with 

small and medium sized sensing fields

It is not recommended for automatic doors with large sensing fields (BFR1 range is recommended) or automatic doors when shopping
carts or trolleys are used.

Technology 

Passive infrared and microprocessor

Optical characteristics

P.I.R. with 4 elements, 15 Fresnel 
lenses with full independent masking 
possibilities

Mounting height

3 m max

Maximum Detection area for mounting height of 2.2m

2.5 m (W) x 1.5 m (D) 

Minimum Detection area for mounting height of 2.2 m

0.5 m (W) x 0.5 m (D) 

Detection mode

motion

Detection speed

0.1 to 1.5 m/s

Light indicator

1 red LED

Warm up

10 s

Hold time

0.5 s or 2 s

Response time

< 200 ms

Power supply

12 VDC –10% to 24 VDC +30%
12 to 24 V AC ±10%

Mains frequency

50/60 Hz

Power consumption

< 1 W 

Connection

small plug-in 5 contacts connector

Recommended cable 
section

< 0.5 mm

2

Length of cable

2.5 m

Temperature range

from –30°C to +55°C

Standard output relay

(free potential change-over contact)

• Max contact voltage 60 V DC/ 42 V AC
• Max contact current 1A (resistive)
• Max switching power 30W (DC) / 60 VA(AC)

Manual adjustments

• shape of sensing field (masking lens)
• sensitivity (dip switch #1)
• relay configuration  (dip switch #2)
• Hold time (dip switch #3)

Immunity

electromagnetic compatibility (EMC) 
according to 89/336/EEC and its 
amendments.

• 

Color 

anthracite grey

Weight

40g

• 

Dimensions 

121mm (W) x 51mm (H) x 40mm (D) 

Degree of protection

IP54

B F P 1  

U S E R ’ S  G U I D E

• The sensor must be firmly 

fastened in order to avoid any 
vibrations

NODETECTION

NO

DETECTION

Guide pins

Cut-Out footprints

Reviews: