4. INSTALLATION REQUIREMENTS
The mechanical structural components must comply
with the requirements of EN 12604:2002. Before
installing the automation, the suitability of the mecha-
nical requirements must be established and any work
that is necessary in order to meet them carried out.
The essential mechanical requirements are as follows:
!
Firm ground to support the weight of the barrier with
flat, horizontal paving. There must be no chance of
water accumulating in the installation area.
The thresholds and protrusions of the paving must
be appropriately shaped in order to prevent the risk
of sliding or slipping.
For the creation of detection loops, refer to the specific
instructions.
Presence of a safety area between the wall (or other
fixed element) and the end of the beam, to protect
against the risk of persons becoming trapped/
crushed.
Presence of safety areas between the fixed and
moving parts to prevent hands from being crushed.
For the minimum dimensions to prevent crushing/
shearing of body parts, refer to EN 349. For the
safety distances required to prevent danger zones
being reached, refer to ISO 13857.
Presence of enough working space needed for the in-
stallation manoeuvres and subsequent maintenance
operations, bearing in mind the opening of the service
door and the positioning/removal of the cabinet and
any other elements.
Absence of fixed or mobile obstacles to the move-
ment of the beam (e.g.: branches, overhead cables,
ceilings).
If the installation area presents the possibility of vehi-
cle impact, provide adequate protective structures to
protect the barrier body.
4.1 MECHANICAL REQUIREMENTS