FAAC 400 Hydraulic Swing Gate Operator
3
11/32”
3
11/32”
4
3/4”
MODEL
CBC
CBAC
SB
SBS
CBACR
CBAC
EG
SB EG
Max Traction / Thrust
Force: (daN)
620
620
620
775
465
465
465
Effective Rod Stroke:
(inches)
10 1/4 10 1/4 10 1/4 10 1/4 10 1/4
15
15
Linear Rod Speed:
(inches/sec)
0.4
0.4
0.4
0.3
0.6
0.6
0.6
Operator Weight: (lbs)
19
19
19
19
19
22
22
Use Frequency:
(cycles/hour)
70
70
70
60
80
50
50
Pump Flow-Rate:
(liters/min)
1
1
1
0.75
1.5
1.5
1.5
Hydraulic Locking:
(
1) = Closing
(2) = Opening and Closing
(1)
(2)
/
/
(2)
(2)
/
Max Leaf Length: (feet)
16
16
18
20
12
18
20
Power Supply
115 VAC ± 10% or 230 VAC +6% -10% 50/60 Hz.
Absorbed Power (W)
220
Absorbed Current (A)
1 (230V) or 2 (115V)
Electric Motor (rpm)
1400 - 4 poles
Thermal Protection
on Winding (°F)
248°
Thrust Capacitor
25uF / 115 V or 8uF / 230 V
Ambient Operating
Temperature Range (°F)
- 4° to 131°
Protection Class
IP55
MODEL 400 OPERATOR
These instructions apply to the following models:
400 CBC, 400 CBAC, 400 SB, 400 SBS, 400 CBACR, 400
CBAC EG, 400 SB EG.
The FAAC Model 400 Swing Gate Operator consists of an electric
pump and a hydraulic piston which transmits drive to the gate leaf.
Models with hydraulic locking do not require the installation of
electric locks, as they provide mechanical locking of the leaf when
the motor is not operating.
Models without hydraulic locking require the installation of electric
locks to ensure that the leaf is mechanically locked.
FAAC 400 Operators
were designed and built to
automate swing
leaf gates. Do not use for any other purpose
.
Dimensions
2. WIRING
Figure 3
1. Operators Mod 400
2. Photocells
3. Electronic control unit
4. Key operated push-button
5. Radio receiver
6. Flashing light
7. Electric lock (if necessary)
Table 1: 400 Operator – Technical Specifications
OPERATOR TYPE
STAN-
DARD
EG
A
OVERALL DIMENSIONS
40 1/2 ”
50 1/2 ”
B
DISTANCE BETWEEN
ATTACHMENTS
27 1/2 ”
32 1/4 ”
C
EFFECTIVE STROKE
10 1/4 ”
15”
1. TECHNICAL SPECIFICATIONS
•
When laying electrical cables, use
conduits with adequate rigidity and flexibility.
•
Always separate low voltage wiring
from AC power cables. Use separate sheaths
to avoid electrical interference.
Figure 2
Figure 1