Description
Action
LED is lit and does not blink.
Solid
LED turns on and off at a regular frequency.
Blinking
LED turns on and off with an irregular frequency and may sometimes appear
solid.
Intermittent
Standard operating states of the status and alarm LEDs
When the unit is in a standard operating state, the status and alarm LEDs behave in a defined manner.
Alarm LED
Status LED
Description
System State
off/none
green solid
Unit is active in a redundant
system configuration.
Active mode
yellow solid
yellow solid
Unit is on standby in a
redundant system
configuration.
Standby mode
red solid
green solid
Host subsystem is halted.
Power standby mode
off/none
off/none
Unit is halted and powered
down.
Powered off
Standard operating states of the power supply LEDs
When the unit is in a standard operating state, the power supply LEDs behave in a defined manner.
Not present
Present and failure
Present and normal
Power Supply
off/none
yellow solid
green solid
Power 1
off/none
yellow solid
green solid
Power 2
LED alert conditions
When there is an alert condition on the unit, the alarm LED behaves in a specific manner.
Description
Action
Alarm LED behavior
System situation
red blinking
Emergency
red solid
Alert or Critical
yellow blinking
Error
Defining custom alerts
The
/etc/alertd/alert.conf
and the
/config/user_alert.conf
files on the BIG-IP system define alerts
that cause the indicators to change. The
/etc/alertd/alert.conf
file defines standard system alerts, and the
/config/user_alert.conf
file defines custom settings. You should edit only the
/config/user_alert.conf
file.
1. Open a command prompt on the BIG-IP system.
2. Type the following command:
10 | Platform Guide: 3900