background image

Types of fuel

Wood

Wood needs to be well seasoned before it is burnt. For the best performance, you should use kiln dried wood 

or seasoned wood with no more than 20% moisture content. As a general guide, wood should be cut to length, 

split and then stacked under cover outside with the sides open to the air, for at least 12 months. You can tell that 
wood is ready for burning when radial cracks appear at the end of the logs. 

It is then good practice to store the wood in a log basket inside your property for a few days prior to its use. The 

internal width of the firebox of the Ion is 330mm, therefore firewood should be no longer than this and a little 

shorter to aid refueling.

Smokeless Fuel

There are several types of smokeless fuel, we recommend only smokeless coal, coke or briquettes that are HETAS 

approved and authorised for use in smokeless zones.  Smokeless fuels can give over 30% more heat and last over 
30% longer than traditional house coals, whilst at the same time emitting upto 80% less smoke and 25% less 

Carbon Dioxide, making it much kinder to the environment.

Smokeless  fuels  have  an  excellent  heat  output  and  a  very  long  fire  life,  that  easily  lasts  through  the  night. 
Smokeless fuels are not difficult to light and produce little ash.

Anthracite

Anthracite is a natural hard, shiny form of coal that is naturally smokeless. Although anthracite can take longer 
to light,  it can burn for very long periods producing a large amount of heat per volume  It can be a higher price-
per-bag than other fuels, but anthracite can work out to be one of the more cost effective fuels long term.

We recommend the small-nut size. Smaller anthracite nuts pack together tighter to create a more intense and 

long lasting fire bed which is popular with those looking for efficient heat. Anthracite is a high performance fuel 
which burns with a high heat and low flame, and leaves little ash behind. Suitable for burning in smoke control 

areas.

Restrictions

 

DO NOT burn unseasoned wood in your appliance.

 

DO NOT burn particle board, lacquered, painted or treated wood, plastics, 

rubber or liquid fuels.

 

DO NOT use starter fluids or liquid fuels to start a fire

 

DO NOT burn waste. This appliance should not be used as an incinerator. 

 

Should the fire be used to burn any of the restricted materials mentioned above, it will not only invalidate your 
warranty but may damage the appliance or cause an unforeseen safety issue.

12

Summary of Contents for iCast Ion

Page 1: ...icast range 1 Ion 5kW Multi Fuel Free Standing Installation and operating manual English ...

Page 2: ...2 Ion 5kW Multi Fuel Free Standing ...

Page 3: ...Safety Installation 4 Safety Ventilation 4 Safety Clean air act 1993 and smoke control areas 5 Adjusting the handle 8 Fitting and connections 9 Testing 9 Before you start 6 Item check list 7 Safety check list 7 Considerations 8 Lighting 10 How to light and sustain a fire 11 Types of fuel 12 Introduction and safety Installation and testing Before you start Operation 3 CONTENTS ...

Page 4: ...ey and appliance beforehand Within the UK Document J of the Building Regulations contains further information regarding the installation of solid fuel appliances This can be viewed by searching for Planning Approved Document J online at www gov uk within the United Kingdom You should also check the relevant planning and building regulations in your own country and your local area as they may diffe...

Page 5: ...993 including designation and supervision of smoke control areas and you can contact them for details of Clean Air Act requirements Our appliance the 5kW Ion multifuel stove has been recommended as suitable for use in smoke control areas when burning wood logs All appliances have been fitted with a modified air control to prevent closure of the secondary air control beyond 6mm 30 open Please note ...

Page 6: ...learance around the 5 flue pipe of 225mm radius above the appliance 3 5 Ensure the suitability of your hearth The appliance should be installed on a minimum 12mm thick non combustible hearth The hearth should extend to a minimum distance of 225mm in front of the appliance and 150mm to each side measured from the door of the combustion chamber Please refer to document J of the building regulations ...

Page 7: ... manufacturer s instructions Please Note Regular maintenance and chimney sweeping is still essential This product weighs 80kg Take necessary precautions and care when lifting and handling this appliance A minimum of two competent people will be required to lift and manipulate this appliance into position Firstly ensure the area is clear and free from obstructions Check the appliance is secure and ...

Page 8: ...ion such as the supplied glove when operating the metal handle as it will become hot during use and for some time afterwards It is recommended that chimneys with a strong updraught be fitted with a flue damper or draught stabiliser to allow the chimney draught to regulate properly No damper should close the flueway completely not less than 20 of the total chimney or flue pipe should remain open at...

Page 9: ...ever outlet is not being used A register plate not supplied may be required to seal off the throat of the fireplace and has a hole for a flue pipe It also provides access for sweeping and if required has a connection for a bracket to support the flue A 5 127mm flue pipe is required from the appliance to the register plate Consult your installation engineer if you require one This appliance has a f...

Page 10: ... oven cured during the manufacturing process However upon initial lighting of the appliance further curing may occur and a slight smell may be evident We recommend that windows and doors are left open during this time which will allow the smell to dissipate Step 1 Place rolled up crumpled paper at the back of the appliance Next place a small amount of tinder kindling on top of the paper followed b...

Page 11: ...f as the height and diameter of the chimney as well as the quality of the fuel used are decisive factors in determining your appliance s efficiency Small hot fires are more efficient than large slumbering ones Most of the energy in burning wood is released as a bright flame The turbulence in the flames creates good mixing between the combustion air and the gases that are released from the wood as ...

Page 12: ...lent heat output and a very long fire life that easily lasts through the night Smokeless fuels are not difficult to light and produce little ash Anthracite Anthracite is a natural hard shiny form of coal that is naturally smokeless Although anthracite can take longer to light it can burn for very long periods producing a large amount of heat per volume It can be a higher price per bag than other f...

Page 13: ...normal and will not interfere with the efficiency of the appliance The vermiculite insulation is not covered by the manufacturer s warranty and may need replacing over time Door glass Blackening of the door glass is usually a result of burning damp wood See Problem solving Blackened glass The longer staining is left to build up on the glass the harder it becomes to clean it off We recommend wiping...

Page 14: ...g temperature Safety Ventilation Smoke in the room when refueling Poor chimney performance Consult a chimney sweep or your installation engineer Check the position of any fitted flue damper to make sure it is in the open position Never open the door when there are high flames on the fuel Wait until the fuel is burning low before refueling Uncontrollable combustion If there is excessive chimney dra...

Page 15: ...pliance over time or ignite the existing accumulation of tar which can result in a chimney fire See Warning below Overheating Should the appliance be allowed to get too hot and overheat you should close the Primary and Secondary air controls fully using the glove provided Keep the fire door closed and allow the fire to burn down and the temperature to drop before allowing air back in gradually See...

Page 16: ...entre from rear intake 132mm to flue centre from rear intake 38mm collar 80mm clearance FRONT BACK 5 Flue 127mm 480mm inc Feet 390mm Top Depth 390mm Inc Handle 455mm 582mm 582mm inc Collar 620mm 330mm internal firebox width Operating parameters Nominal heat output 5kW Ideal operating temperature range 150 300 C Efficiency 79 9 Wood 80 Anthracite SPECIFICATIONS 16 ...

Page 17: ...f the England and Wales Building Regulations 2000 Who certifies that this installation is safe has been demonstrated to the householder conforms to current building regulations has at least a 12Pa flue draught measurement and has been through these instructions with the owner of the appliance TO FIND A QUALIFIED INSTALLER FUEL SUPPLIER or CHIMNEY SWEEP CONTACT UK TheSolidFuelAssociation 95HighStre...

Page 18: ...Installer notes 18 ...

Page 19: ...Thank you for choosing F2 Fires sit back relax and enjoy 19 ...

Page 20: ...hnical support Trident House 1 Tower Road Business Park Darwen Lancashire BB3 2DU Tel 44 0 1254 205739 Fax 44 0 1254 790878 support f2fires co uk www f2fires co uk F2 Fires Limited UK Tel 44 0 1254 205739 Fax 44 0 1254 790878 info f2fires co uk www f2fires co uk ...

Reviews: