ATR833A-II / P/N 833-II (Axxx)-(Axxx)
Operation and Installation
Doc.-No. 01.143A.010.71e / Revision 1.00
38
4.5 Mounting
In cooperation with a maintenance shop, location and kind of the
installation are specified. The maintenance shop can supply all
cables. Suitable sets of cables are available from f.u.n.k.e.
AVIONICS GmbH.
Select a position away from heat sources. Care for adequate
convection cooling.
Leave sufficient space for the installation of cables and connectors.
Avoid sharp bends and wiring close to control cables.
Leave sufficient lead length for inspection or repair of the wiring of
the connector.
Bend the harness at the rear connectors to inhibit water droplets
(formed due to condensation) from collecting in the connector.
For mounting details/drawing refer to chapter 4.11.2
4.6 Equipment Connections
One 25 pin D-SUB miniature connector includes all electrical
connections, except for the antenna.
4.6.1 Microphone Connection
The standard microphone inputs provide phantom power of 9V. The
sensitivity can be set in the configuration menu (see chapter 3.7).
Standard microphones (headset) and dynamic microphones (hand /
gooseneck) can be connected at the same time. With setting MIC type
auto, the dynamic microphone connection has priority over the standard
microphone.
The (+UB)-wire (PWR
– Pin 11/12) has to be protected by a
circuit breaker (4 Amp. slow-blow)!