background image

Please read this manual instruction thoroughly before use.

Non-Contact Forehead Thermometer

Version: V2.0   Date: 2020-06-08

Compliant to IEC 60601-1, IEC60601-1-11, IEC 60601-1-2, 

Heavy Duty Sensor

IEC 62304, ISO80601-2-56, ASTM E1965-98 
Manual instruction

Model: HW-F7

Summary of Contents for HW-F7

Page 1: ...ction thoroughly before use Non Contact Forehead Thermometer Version V2 0 Date 2020 06 08 Compliant to IEC 60601 1 IEC60601 1 11 IEC 60601 1 2 Heavy Duty Sensor IEC 62304 ISO80601 2 56 ASTM E1965 98 M...

Page 2: ...eter and open the battery lid to install 2 AAA batteries 2 Keep distance at 5cm to 8cm from thermometer probe to the middle of forehead please do not contact forehead directly 1 9 3 1 IN Distinguish t...

Page 3: ...r human body mode 3 Select measurement mode and click the measurement button to start taking temperature 4 Reading displays on the screen after successful measurement Measurement button the icon for o...

Page 4: ...ter is cost effective and is widely used in schools customs hospitals and for family use Intended Use Indication for use The Non Contact Forehead Thermometer is an infrared thermometer intended for th...

Page 5: ...d tissue or tissue compromised by skin disorders because they will affect the accuracy of measurement Do not measure if patient is treated with certain drug therapies because body temperature may rise...

Page 6: ...ient can measure read data and replace battery under normal circumstances and maintain the device and its accessories according to the user manual The PATIENT is an intended OPERATOP Don t use this th...

Page 7: ...13 131 RH 95 Non condensing 6 Illustration Power supply d c 3V 2 AAA Batteries Power consumption When off 10uW When measurement 30mW Shelf life 5 Year Memory Storage of last 10 readings Display 3 Col...

Page 8: ...t mode Battery level Details Icon Function definition 7 Display icons When thermometer is on it displays current Reading scale Press the C F button to select reading scale Reading scale setting fig 9...

Page 9: ...value is 38 it gives beep beep beep as a indication After measurement if the thermometer is idle for 30 seconds it will display OFF fig 10 5 and gives a beep and shut off automatically 10 1 Body tempe...

Page 10: ...ig 10 10 fig 10 11 fig 10 12 12 Maintenance tips Make sure the sensor and probe cavity is clean otherwise it will affect accuracy Cleaning method for probe 1 Use the cotton stick or soft cloth with wa...

Page 11: ...or take out the battery and install the battery again Strong crash or hit to the product will cause its damage Do not dismantle this thermometer by yourself Keep the thermometer from children s reach...

Page 12: ...rective If you have any queries please refer to the local authorities responsible for waste disposal Dispose of empty battery at your retail store or at appropriate collection sites according to natio...

Page 13: ...The customer or the user of infrared thermometer should assure that it is used in such an environment Guidance and manufacturer s declaration electromagnetic immunity for all EQUIPMENT and SYSTEMS Gui...

Page 14: ...age variations on power supply input lines IEC 61000 4 11 2 kV for power supply lines 1 kV for input output lines 1 kV differential mode 2 kV common mode 0 UT 0 5 cycle g At 0 45 90 135 180 225 270 an...

Page 15: ...nication equipment Refer to table 9 of IEC 60601 1 2 2014 N A 10 V m 80 MHz to 2 7 GHz 385MHz 5785MHz Test specifications for ENCLOSURE PORT IMMUNITY to RF wireless communication equipment Refer to ta...

Page 16: ...bile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electroma...

Page 17: ...power rating of the transmitter in watts W according to the transmitter manufacturer NOTE 1 At 80 MHz and 800 MHz the separation distance for the higher frequency range applies NOTE 2 These guideline...

Page 18: ......

Reviews: