Page 6
Detailed Review of Preferences Items
ADDR#1
: If working with Target Manager (TMGR), this address must match the
RCAD
value on
TMGR setup menu.
ADDR#2
: If working with TMGR, this address must match the
RCCH
value on TMGR setup
menu.
TXBR:
If working with TMGR, this value must match the
RCBR
value on TMGR setup menu.
TXDIRECT
: When set to 1, the MTX-8 can control traps directly without counting targets. Set to
0 to work with Target Manager (TMGR) target inventory and payment control system.
GAME:
The game type for automatic sequence control. This value is currently fixed to 01 for
Five-Stand.
MENU:
The menu number that will be used for automatic sequencing mode. There are 6 Five-
Stand menus that can be modified by the club’s administrator. Select the menu that will be
available to the users. See the built-in menus in Appendix 1.
CHAR/#:
If you would like to identify the traps numerically, set to 0. Otherwise, set to 1 to
identify traps by alphabetical order (A-H).
IDLTIME:
Select how many minutes of idle time (no key presses) will pass before the MTX-8
will automatically turn OFF. Once OFF, you will need to press the ON/OFF key [
] to resume
operations from where you left the unit.
FPDLAY:
Default Following-Pair delay in seconds. When you program an automatic target
sequence, you have an option to select a Following-Pair in which the second target will be
delayed by anywhere from 1 to 6 seconds. The FPDLAY is the default value that will be assigned
automatically when you select a Following-Pair release mode. You can then modify the delay for
each individual pair on the menu.
BACKLIT:
This item controls the LCD back light. LCD backlight consumes considerable power
and reduces the battery life. Unless using the MTX-8 at night, set this parameter to 00 = LCD
backlight OFF. Otherwise, set to any value up to 15 seconds. The backlight will turn ON after
each key press and will stay on for the duration selected.
RESERV1 & RESERV2:
Items currently not accessible.
PW-1 through PW-4
: Select and set a 4 digit password to access Setup Menus. You will need
to remember this number in order to access the setup menu. The password is intended to
prevent users from tampering with the MTX-8 setup. Do not leave the device without a
password. Write the password and save in a safe place.