CORRECTIVE ACTION IN CASE OF FAILURE
(1) The operating switch is switched on, but the motor is
not working.
• Wires in the mains plug or in the socket are loose:
Have socket and plug checked or repaired
• The switch is faulty:
Have the switch replaced.
(2) The operating switch is switched on, but unusual
noises can be heard, the motor is not working or
only very slowly.
• Switch contact has failed:
Have the switch replaced
• Component jammed:
Have the electric tool checked or repaired
• Too much thrust, as a result the motor is dragging:
Use less thrust during the task
(3) Motor gets hot.
• Foreign substances have got inside the motor:
Have the foreign substances removed
• Lack of or contaminated lubrication grease:
Have lubricating grease applied or replaced
• Pressure too high:
Use less thrust during the task
(4) Frequent or strong sparks on the commutator.
• Short circuit on the armature:
Have the armature replaced
• Carbon brushes worn out or jammed:
Have the carbon brushes checked
• Rough running of the commutator:
Have the surface of the commutator cleaned or ground
For your own safety, never remove parts or accessories of
the electric tool during operation. In case of fault or damage
have the electric tool repaired only by a specialist workshop