EZA EZARMPPT10 Manual Download Page 19

Secondary browsing interface under the condition of battery voltage interface 

- Long press the + button in the main loop of the battery voltage interface to enter the secondary browsing 

interface, 

- short press the + or - button switch to the secondary browsing interface, 

- long press the + button to enter the setting interface, short press + or - button to the set the parameters - 

and long press + to save. 

It will automatically exit the secondary browsing interface without anything for 15 seconds. 

Summary of Contents for EZARMPPT10

Page 1: ...FR EN EZAR MPPT REGULATEUR SOLAIRE MANUEL UTILISATEUR WWW EZA FR...

Page 2: ...ute qualit sont utilis s pour am liorer les performances du syst me r ali ser des donn es en temps r el Vitesse de surveillance de puissance maximale tr s rapide tout en assurant l efficacit de la pou...

Page 3: ...e communication Rj45 S lection 7 Bouton 8 Sortie USB 9 Bouton 10 Planche de refroidissement AVERTISSEMENT Dans le cas o la sonde de temp rature distance n est pas connect e le con tr leur com pense le...

Page 4: ...ifier si l cran d affichage est allum Si cela ne fonctionne pas ou si l affichage est anormal reportez vous la section 6 pour le d pannage AVERTISSEMENT Cette s rie de MPPT contr le les positifs commu...

Page 5: ...e de naviga tion secon daire puis appuyez sur le bouton ou pour acc der au mode de r glage appuyez longuement sur le bouton pour acc der au mode de r glage appuyez bri vement sur le bouton ou pour r g...

Page 6: ...e et temp rature ambiante Remarque A la premi re connexion de l interface de navigation appuyez longuement sur la touche pour entrer dans la fen tre de navigation secondaire Le syst me quittera automa...

Page 7: ...selon la temp rature Mode de chargement Num ro de communi cation distance Une fois dans l interface de Voltage batterie Appuyez longuement sur le bouton pour acc der l interface de navigation Appuyez...

Page 8: ...p Le jour il fonctionne PROFIL DE CHARGE Mode double fuseau horaire Le r gulateur est param tr pour commencer charger le matin une certaine heure et per mettre l alimenta tion du 12 volt par la batter...

Page 9: ...ut Clignotement 4 4 Type de batterie Six familles de batteries peuvent tre s lectionn es Par d faut utilisateur scell es inond es GEL LiFe PO4 Li NiCoMn O2 Parmi eux les param tres par d faut de l uti...

Page 10: ...ppuyez longuement sur le pour acc der l interface de r glage puis appuyez bri vement sur les touches ou pour s lectionner le mode AUTOMATIQUE 12V ou 24V puis appuyez longuement sur la touche pour sauv...

Page 11: ...Surtension de la batterie D charge excessive de la batterie Batterie peut tre sauvegard e si le Panneau solaire n est pas connect La tension de la batterie atteint le point de surtension Condition R s...

Page 12: ...prend que lorsque la tension de la batterie est suffisante Surtension de de la batterie de stockage V rifier si la tension de la batterie d passe la tension et rebranchez le panneau solaire Sur consom...

Page 13: ...vert 14 6V Auto consommation D connexion Basse Tension Dur e de la charge d absorption 2hs 16 Volt 45mA 12V 37mA 24V Dur e de la charge d quilibrage Coefficient de compensation de temp rature Chute de...

Page 14: ...king efficiency is no less 99 5 High quality components are used to improve the system performance realize real time data view and parameter setting function Very fast maximum power monitoring speed w...

Page 15: ...inal 6 Rj45 communication interface Selection 7 Button 8 USB output 9 Button 10 Cooling board NOTICE In the case of the remote temperature sensor not connected the controller will compensate the char...

Page 16: ...control system and observe whether the display screen is lighted Of it doesn t work or the display is abnormal refer to section 6 for troubleshooting NOTICE This series of MPPT is a common positive c...

Page 17: ...the secondary browsing interface and then press or to browsing intergace long press button again to enter the setting mode short press button or button to set parameters then long press button to save...

Page 18: ...tery voltage and ambient temperature Notice At the first lever browse interface long press button to enter the secondary browsing inter face It will automatically exit the secondary browsing interface...

Page 19: ...e interface to enter the secondary browsing interface short press the or button switch to the secondary browsing interface long press the button to enter the setting interface short press or button to...

Page 20: ...he letter h serves as a distinction Interface de voltage batterie Information module solaire Tension et temp rature CODE Regular mode Light control mode LOAD PATTERN Dual time mode Charge only mode Th...

Page 21: ...storage battery Flicker Specification Flicker Overloarding trouble Fault indicator Flicker 4 4 Battery type Six type of batteries for user choosing User default Sealed Flooded GEL LiFePO4 Li NiCoMn O...

Page 22: ...4 5 System voltage selection Long press in the system voltage interface enter the setting interface short press or to select system voltage long press again to save the selected system voltage...

Page 23: ...cted Battery is reserved Battery over voltage Battery over discharge Battery can be reserved if PV is unconnected Battery voltage reaches the over voltage point Condition Status Controller ins t broke...

Page 24: ...o ma tically and recovers when battery electricity is enough Over voltage of storage battery Please check whether the battery voltage exceeds the voltage and reconnect the solar panel Over load Reduce...

Page 25: ...ry 13 8V Maintenance free lead acid battery 14 4V GEL 14 2V Lead acid Flooded battery 14 6V Static loss HVD Duration of absorption charging 2hs 16 Volt 45mA 12V 37mA 24V Duration of equa lized chargin...

Page 26: ......

Reviews: