12
8) To clean, dampen a cloth with cleaning solution and wipe down the unit.
9) Inspect the lift cable and clip for any signs of wear.
10) Perform a visual inspection of the lifting cable. If damage or wear of the cable
coating or fraying of the cable is present, contact EZ Way to replace the cable.
Remove the cover on the end of the boom to inspect the cable end where it is
attached to the actuator. Perform a visual check to verify that the crimped sleeves
are holding the cable ends.
Mast Actuator Inspection:
1) Inspect the plastic housing for any dents or cracks.
2) Inspect the cables to see if they have been cut or pinched.
3) See if the actuator appears deflected when fully extended at full load.
4) Verify that the mounting points do not have any cracks or other defects.
5) Verify that the inner or outer tubes do not have any dents, dings, or large
scratches in them.
Contact EZ Way’s Service Department if the actuator shows any signs of the issues
listed above.
**IMPORTANT NOTICE**
The SKF Magnetic Actuator used on this unit should be replaced after 10 years or 20,000 double
strokes (up and down) per the original manufacturer.
It is the responsibility of the purchaser to ensure that regular maintenance inspection is conducted
on this device by competent staff.