and “-” as illustrated for proper installation.   
Cover the battery lid and secure the screw.   
 

Maintenance, storage and calibration 
 
Maintenance:

 

1. Remove any dirt of stains on the body of the thermometer with a soft and dry cloth. 
2. Do not wash with water or detergent containing abrasive or benzene.   

 
Storage:

 

1. Clean the thermometer after each use.   
2. Don’t leave the thermometer exposed to direct sunshine, high temperatures, dampness, fire, flame, vibration or 

impact. 

3. Remove the battery if you are storing for an extended period of time.   
 

Calibration : 

This thermometer is calibrated at the time of manufacture. If the thermometer is used according to instructions, 
periodic re-calibration is not required. If at any time you question the accuracy of the measurement, please contact 
your retailer. 
 
Don’t attempt to modify or reassemble the thermometer.   
 

Summary of Contents for Thermo Talk IRE-A1

Page 1: ...ge to house family property domestic animal and pet Marks or Symbols Means Notice with detailed items expressed in words or figures within or beside Left symbol means Do not break Means DO NOT with de...

Page 2: ...the ear canal It is not recommended to use the product in the presence of ear disease such as otitis externa and tympanitis Affected part may deteriorate Don t use the product in a wet ear after swimm...

Page 3: ...perature may vary with age time and ambient temperature Typically ear temperature is higher than temperature measured under the arm The graph below provides the normal distribution for body temperatur...

Page 4: ...ad from the LCD 3 The result will be stored into memory automatically If 30 sets of memory are stored already the oldest set of data will be automatically removed and the most recent will be come the...

Page 5: ...cally 5 seconds after last Memo key pressed For setup mode 1 Press Talk to shift between a setting of hour minute year month and date 2 Press Memo to increase the digit and press Talk for confirm 3 Pr...

Page 6: ...thermometer after each use 2 Don t leave the thermometer exposed to direct sunshine high temperatures dampness fire flame vibration or impact 3 Remove the battery if you are storing for an extended pe...

Page 7: ...ower consumption 0 05W for voice prompt 5 Temperature sensing part Infrared sensor 6 Measurement range 32 0 42 9 89 6 109 3 7 Measurement accuracy 0 2 or 0 4 from 36 0 39 0 or 96 7 to 102 2 0 3 0 5 fr...

Page 8: ...h electrostatic discharge the unit may malfunction and may require user to reset the unit 2 Dispose with care please consult the retailer for details Manufacturer Tremblay Harrison Inc 1684 Dufferin S...

Reviews: