EZ Digital GP-3010 Operation Manual Download Page 7

4. Do not place liquid-filled containers on top of  this instrument.

A spill could seriously damage the instrument.

5. Do not use this instrument where it is subject to serve viration,or strong blows.

6.Do not place heavery objects on the case,or otherwise block the ventilation hole

7. Do not use this power supply in strong magnetic fields,such as near motors.

8. Do not insert wires , tools , etc. through the ventilation holes.

9. Do not leave a hot soldering iron near the instrument.

10. Do not place this instrument face down on the ground, or damage to the knob
      may resuit.

11. Do not connect other power source to + ,- of the output terminal.

12. Ground terminal of power code must connect to the ground.

13. According to output porarity, it solved problem ESD and Floating voltage using

  the connect ground port to terminal of output .

14. To connect the ground, be careful at ground  porarity of load.

15. Input voltage of instrument must be equal to AC power voltage.

16. It use to thick and short wire of output terminal in possible.

3-3. Cleaning 

1. To clean stained casing, lightly rub the stained area with a soft cloth dipped in a
     neutral detergent.

2. If the surface of the panel is dirty, use the same method to clean.

If the panel is heavily stained, rub the affected area lighty with a soft cloth soaked
in light neutral detergent or alcohol.

3. Never use highly volatile material such as benzene or paint thinner.

[5]

Summary of Contents for GP-3010

Page 1: ...DC Power Supply ...

Page 2: ...mpaired CAUTION AND WARNING STATEMENTS CAUTION Is used to indicate correct operating or maintenance procedures in order to prevent damage to or destruction of the equipment or other property WARNING Calls attention to a potential danger that requires correct procedures or practices in order to prevent personal injury SYMBOLS Caution risk of electric shocks Easily touched higher temperature parts C...

Page 3: ... Storage temperature 0 70 2 For quality improvement the exterior design and specifications of the product can be changed without notice 3 Should any further information be required please contact the EZ DIGITAL company or sales outlet WARRANTY Warranty service covers one year the date of original purchase In case of technical failure a year repair service will be provided by EZ DIGITAL company We ...

Page 4: ...ecautions 3 3 Cleaning 4 SPECIFICATION 5 PANEL DECRIPTION 5 1 Front Panel Description 5 2 Rear Panel Description 6 OPERATIONS 6 1 Independent Operation 6 2 Seriall Operation 6 3 Parallel Operation 7 NOTES ON ENVIRONMENTAL CONDITION 8 CURRENT LIMITING CIRCUIT 9 EXCHANGE METHODE OF FUSE 2 CONTENTS ...

Page 5: ... variable current adjustment in a range of 10 to 100 Current limiting and overload protection functions are built in to protect the load under any circumstances The supply features anloge voltmeter and amperemeter enabling the user to monitor the supply s operation at a glance LEDs for Constant current C C and Constant Voltage C V enables monitoring of operation status Main input voltage AC230V an...

Page 6: ... out the line fuse holder containing the fuse for overload protection Replace the fuse in the holder with the correct fuse from table3 1 plug it in Table 3 1 Line voltage Selection Fuse Ratings AC 90 110 100V AC 108 132 120V AC 198 242 220V AC 207 250 230V 3 2 INSTALLATION HANDLING PRECAUTIONS When placing the power supply in service at your workplace observe the following precautions for best ins...

Page 7: ... source to of the output terminal 12 Ground terminal of power code must connect to the ground 13 According to output porarity it solved problem ESD and Floating voltage using the connect ground port to terminal of output 14 To connect the ground be careful at ground porarity of load 15 Input voltage of instrument must be equal to AC power voltage 16 It use to thick and short wire of output termina...

Page 8: ...on Voltmeter Monitor Ampermeter Monitor Insulation between Accessories Ambient temperature Compensation Protection circuit Operating Humidity 0 5A Power Consumption Less than 3mVpp Less than 0 01 3mV for load variation of 0 to 100 Accuarcy of 2 5 for full scale Accuarcy of 2 5 for full scale 5 40 Dimension Weight Power source 80 50 235 W x 145 H x 380 D GP 305 GP 3010 GP 503 GP 505 Positive Negati...

Page 9: ... 6 ...

Page 10: ...e the power is off 8 CURRENT METER Indicates the load current 9 ZERO ADJUST The mechanical zero adjuster screw for voltmeter If the meter needle is off the zero position adjust the screw while the power is off 10 VOLTAGE METER Set an output voltage while reading the voltage indication 11 OUTPUT TERMINAL The negative side of output terminal 12 OUTPUT TERMINAL The positive side of output terminal 13...

Page 11: ...5 2 Rear Panel Description 1 DC FAN 2 SERIAL NUMBER 3 AC INLET 4 VENTILATION 8 2 3 1 4 ...

Page 12: ...The specifications are subjected to change without notice ...

Reviews: