![EZ Digital FG-7005C Operation Manual Download Page 6](http://html1.mh-extra.com/html/ez-digital/fg-7005c/fg-7005c_operation-manual_2457870006.webp)
SWEEP FUNCTION CHARACTERISTICS
Mode
: Linear
Width
: Variable from 1 : 1 to 100 : 1
Rate
: 0.5 Hz to 50 Hz (20 mS to 2 S)
External VCF Input
: Input Voltage : 0 to 10 V
Input Impedance
: Approx. 10 K
Ω
FREQUENCY COUNTER CHARACTERISTICS
Display
: 6 digit green LED, Gate time, MHz, KHz, Hz, mHz.
Frequency Range
: 500 mHz to 50 MHz With Auto Range.
Accuracy
:
±
Time base Error
±
1 count
Time base
: 10 MHz
Input Sensitivity
: 100 mVrms
Max. Input Voltage
: 250 Vp-p
DIMENSION AND WEIGHT
Dimension
: 255(W)x 255(D) x90(H)mm
Weight
: Approx. 2.0Kg
1-3. Equipment Ratings
Input Voltage
Fuse
Power Max.
103 126V AC(50/60Hz)
F 0.5A 250V
15W
206 252V AC(50/60Hz)
F 0.25A 250V
15W
Operating Environment
TEMPERATURE
: 0
°
C to + 40
°
C
HUMIDITY
:up to 85% to 40
°
C without temperature extremes
causing condensation within the instrument.
Storage Environment
TEMPERATURE
: -20
°
C to +70
°
C
HUMIDITY
: below 85% RH
Insulation Category II : Portable equipment of local level.
Pollution Degree : 2
Protection to IEC 529 : Ordinary