-2-
•
JP/LK:
Lock control jumper, to select the lock type(see 5.2.1 , 5.2.2).
•
Main Connect Port:
To connect the bus line and the electronic locks.
•
BUS: Connect to the bus line, no polarity.
•
PL: External lock power input, connect to the power positive(power +).
•
S+: Lock power(+) output.
•
S-: Lock power(-) output, connect to the power(-) input of locks(only when using the camera to
power the locks, if using the external power supply for the locks, the S- will not be connected).
3.Specifications
•
Power Supply :
DC 24V;
•
Lock Power supply:
12Vdc, 300mA(Internal Power);
•
Power Consumtion: Standby 33mA; Working status 110mA;
•
Camera:
Color ARS; 650 TV Lines;
•
Unlocking time:
1~30s(Default 1s);
•
Working temperature: -15ºC ~ 55ºC;
•
Dimension:
188(H)×110(W)×39(D)mm.
4.Mounting
4.1 Mounting
1
2
5
4
Drill a hole in the wall to match the size of the
mounting box and attach to the wall.
Attach the panel to the mounting box and
use screws supplied to fix the panel
3
Connect the cable correctly