background image

                                      

FHD

 

Series Floodlight                                                                                        

 

                                                                                                                                                                                     

EQS3367 Rev: 1  4/27/2015

 

 
 

INSTALLATION INSTRUCTIONS 

IMPORTANT SAFETY INSTRUCTIONS:  

This equipment is intended to be installed by qualified personnel.  The installation 

must be made in accordance with the current edition of the National Electric Code, and all applicable state and local building codes.  
The final installation must be approved by the appropriate, qualified, electrical/building inspector(s).  Improper Installation may 
result in a risk of fire or electrical shock hazard.  The instructions provided herein are made available for reference when installing 
the FHD Heavy Duty Flood Light.  If any portion of these installation instructions is unclear then do not proceed with the installation 
and contact an EYE Lighting Representative at 

1-888-665-2677

.  

 
 
 
 

READ AND FOLLOW ALL SAFETY INSTRUCTIONS BEFORE STARTING INSTALLATION

 

 
WARNINGS AND CAUTIONS:  

 

 

 

CAUTION 

– RISK OF SHOCK – DISCONNECT POWER BEFORE INSTALLATION

 

 

Failure to provide proper luminaire grounding may result in serious personal injury. 

 

Maintain minimum distance of 0.5 m (1.6 ft) from walls or any other flammable surface. 

 

Maintain minimum distance of 1.0 (3 ft) from lighted objects. 

 

Do Not operate with cracked and/or broken glass cover. 

 

Do Not Install close to a Heat Source.  

 

Do Not use the luminaire to support ones weight, do not hang onto luminaire.  Wear proper equipment, including 
safety glasses and gloves, when installing and servicing luminaire. 

 

Improper installation and/or utilization may void manufacturer’s warranty. 

 

Use secondary safety chain or cable, as needed, when securing floodlight. 

 

Allow sufficient cool down time prior to handling and/or servicing floodlight.

 

 

SUITABLE FOR MOUNTING WITHIN 1.2 m (4 ft) OF THE GROUND

 

 
 

DO NOT OPPERATE 
IF CRACKED OR BROKEN 
 

 

 

 
Tools required:    

Installation is completed using ordinary tools including:    

 

Ratchet wrench (with 12mm Socket head) or 
an adjustable Crescent wrench. 

 

Torque wrench capable of 11 NM (8.11 ft-lbs.) 

 

 

No. 8 Metric or 5/16 SAE Allen Wrench 

 

Wire Strippers  

 

#2 Phillips Screwdriver 

Before Installation: 

 

 

Inspect luminaire for defects prior to installation.   It is unlikely that mount arm or covers have 
loosened during shipment, visually inspect.    If defects are noticed then do not install and contact 
the manufacturer immediately. 

 
 
 

Weight 

14.7 kg ( ~ 32.4 lbs.) 

Input Voltage / Frequency 

120 – 277 Vac  /  50-60 Hz 

Wattages 

185W, or 230W 

IF GLASS IS CRACKED OR BROKEN DO NOT OPPERATE CALL MANUFACTURE FOR REPLACEMENT GLASS 