background image

DIMMING KNOB

The system dimming knob can be used to lower the light output or turn the 

system off. The knob has nine (9) locations 

(Figure 4)

. Use the following guide 

for the power level at each position:

MAINTENANCE AND REPAIR

CAUTION: Do not clean the LED system with detergents or abrasive substances.

Turn off the LED system before performing any maintenance.
Regularly check the LED system for dust, debris or dirt buildup and clean if 

necessary. Contamination may cause decreased performance. To properly 

clean the system, use a dry or damp lint-free cloth. To properly clean the LED 

boards, gently wipe down with a microfiber towel.
Regularly check the power cord and hanging cables of the LED system to 

ensure there is no damage.

WARRANTY INFORMATION

For complete warranty details, visit eyehortilux.com/warranty
EYE HORTILUX Ascend LED Grow Light Systems

 

5-year limited warranty from the date of purchase.

EYE Lighting International of North America warrants HORTILUX Ascend LED 

Grow Light Systems to be free from defects in material and workmanship 

during the period ending five (5) years from the original date of purchase. 

LEDs are guaranteed to maintain 90% or better light output for those five (5) 

years during normal operation. If the product shows any defects within this 

period and that defect is not due to user error or improper use, EYE Lighting 

shall, at its discretion, either replace or repair the system using suitable new 

or reconditioned parts. Some States do not allow limitations on how long an 

implied warranty lasts, so the above limitation may not apply to you.
EYE Lighting offers this warranty ONLY to the original purchasers of EYE 

HORTILUX Ascend LED Grow Light Systems. All warranty claims must be 

directed to the retail store where the EYE HORTILUX product was purchased.

LIMITATION OF LIABILITY

The warranty and remedies set forth herein are in lieu of any and all other 

warranties express or implied, including any warranty of merchantability 

or fitness for a particular purpose. EYE Lighting shall not be obligated or 

liable for any indirect, consequential or incidental damages for breach of 

this or any other warranty, express or implied, or for any claim based on 

contract, tort or any other legal theory. In no event shall EYE Lighting’s 

liability exceed the purchase of the product. Some states do not allow the 

exclusion or limitation of incidental consequential damages, so the above 

limitation or exclusion may not apply to you.

EYE Lighting International of North Amer

ica, Inc.

a division of Iwasaki Electric of Japan

9150 Hendricks Road 
Mentor, Ohio 44060

Tel:    (877) 905-2562
Fax:  (800) 811-7395

[email protected]

www.eyehortilux.com

HORTILUX® is a trademark of Iwasaki Electric Co., and is registered in USA and Japan

(Figure 4)

Knob 

Position

Power 

Level

Input 

Watts

0

0%

0

1

16%

56W

2

30%

105W

3

42%

147W

4

53%

186W

5

65%

228W

6

75%

263W

7

85%

298W

8

95%

333W

9

100%

350W

SPECIFICATIONS

SPECTRUM

Model

LED 350-ES

Wattage

350W

Input Voltage

120V

240V

277V

Amperage

2.9A

1.6A

1.3A

Power Cord

12 ft.

Weight

25 lbs.

Dimensions – L x W x H 

in. (mm)

44.8 x 24 x 3.9  

(1143 x 609 x 99)

Typical Power Consumption

350W

Operating Frequency

50-60Hz

Power Factor

>0.95

Thermal Management

Passive

Environment

Designed to meet IP66

Dimming

Yes

PPF* (400-700 nm)

675 µmol

PBF* (375-800 nm)

800 µmol

PPF Efficacy

1.9 µmol/J

PBF Efficacy

2.3 µmol/J

PPFD Average* (400-700 nm)

340 µmol/m

2

-sec

PBFD Average* (375-800 nm)

400 µmol/m

2

-sec

Light Uniformity – max/min

3.4/1

Light Uniformity – avg/min

2.2/1

Coverage Area

3 ft. x 4 ft.

Height Above Canopy

18 in.

Distance between fixtures**

8 in.

*UV and Far Red are not counted in PPF or PPFD measurements. PPFD and PBFD measurements were taken 

in a 10ft x 10ft room with average reflective material at the optimal setup recommendation. PPFD and PBFD 

in actual applications will vary.  |  **The distance between fixtures should be measured from the edge of the 

system.  |  Plug end power cord available for purchase on 120V, 240V and 277V.  |  347V and 480V are MTO.  

100

90
80
70
60
50
40
30
20
10

0

400

420

440

460

480

500

520

540

560

580

600

620

640

660

680

700

720

740 

Spectral range in nanometers

Percent of relative energ

y

760

780

800

360

380

UV RANGE

FAR RED RANGE

8”

8”

8”

8”

Reviews: