3 Installation and Setting-to-Work
3.1 Installation
The iWAP300 is simple to install and can be secured directly to suitable surface
using the mounting holes on the Enclosure.
3.1.1 Removing the cover
Unscrew the four screws and remove the enclosure lid.
.
Diagram 3.1.1
3.1.2 Fitting the cables
Depending on the configuration of the iWAP300, the connections for power and
communication will need to be terminated into the enclosure via the correct cable
entries shown in Diagram 3.1.1.
The cables used to connect the power and/or Ethernet connection to the PCB screw
terminals must conform to the following specification;
All wires should be stripped and, if stranded cable is used, should be crimped using
2.5mm bootlace ferrules. The stripped/crimped wires should then be placed into the
corresponding screw terminal and securely screwed in place.
If using solid core cable;
Minimum cross section of cable = 0.2mm
2
Maximum cross section of cable = 2.5mm
2
Lid
screws
Lid
screws
Ethernet
Cable Entry
5.8 GHz
Antenna
Connections
Top Row
2.4GHz
Antenna
Connections
Bottom Row
AC/DC Power