background image

 

 

13 

The  charger  input  conditions  listed  in  the  Special  Conditions  of  Safe  Use  must  be 
observed.  Charging is only permitted between 0

o

C and 45

o

C.  When connecting to a 

USB power supply, ensure the supply is rated less than 100W. 
 

Warning!  

Ensure  that  the  Photo  ID  retention  screw  is  fully  tightened  prior  to 
charging. 

 
Alternatively the iTAG X-

Range can be charged using Extronics’ custom Multicharger, 

Figure 16.  Please contact Extronics for further information. 
 

 

Figure 16. 

4.4.3  Variances in battery life 

Variances  in  battery  life  are  based  on  usage.  Actual  results  may  vary  due  to  the 
following:

 

 

  LF exciter usage. 

  Changes in tag usage. 

  Time in storage before use. 

  Changes in transmission interval. 

  Temperature. 

  Motion. 

  Indoor/Outdoor applications. 

  Time to receive firm GPS co-ordinates. 

 
The iTAG X-Range uses different proprietary techniques to maximise and optimise the 
life of the battery. 
 

Summary of Contents for iTAG X-Range

Page 1: ...ty information refer to Terms and Conditions at http www extronics com 2021 Extronics Limited This document is Copyright Extronics limited Extronics reserve the right to change this manual and its con...

Page 2: ...n 9 3 9 Man Down 9 3 10 Battery and battery life 9 3 11 Mounting 9 3 12 Simple configuration 9 3 13 Motion sensor 9 3 14 Integrated access control 9 3 15 Rugged performance 10 4 iTAG X Range Usage Ins...

Page 3: ...dous areas The iTAG X Range provides audible visual and tactile alerts to provide real time alerting and reporting for worker location solutions 1 1 What is inside the box Example above is the same fo...

Page 4: ...m IBSS Independent Basic Service Set LF Low Frequency OTA Over The Air PC PBT Polycarbonate Polybutylene Terephthalate PELV Protective Extra Low Voltage PPE Personal Protective Equipment SD CT Social...

Page 5: ...paratus complying with the IEC 60950 series IEC 61010 1 or a technically equivalent standard see Appendix 1 for suggestions or o fed directly from cells or batteries iTAG X Range charger input Um 6 5V...

Page 6: ...que votre iTAG X Range convient la zone dangereuse dans laquelle il doit tre utilis Warning Before setting the units to work read the technical documentation carefully Avant d utiliser les unit s lis...

Page 7: ...7 2 4 2 MET North America and Canada Where aa denotes model type XXXXXX is the serial number ZZZZ is a code to identify model variants Exact layout of markings may differ from that shown...

Page 8: ...col used during Over The Air OTA updates The tag has firmware OTA update capability which can be used when new functionality becomes available This eliminates the need to return the iTAG X Range to th...

Page 9: ...he front cover See X127637 for further details 3 10Battery and battery life The iTAG X Range has a long lasting rechargeable lithium ion battery Minimum expected battery service life is 2 years 3 11 M...

Page 10: ...fied PBT s have excellent resistance to a broad range of chemicals at room temperature including aliphatic hydrocarbons gasoline carbon tetrachloride perchloroethylene oils fats alcohols glycols ester...

Page 11: ...our LEDs on the top and front Indications are shown in Table 1 Indication LED colour LED position Sound Vibrate Tag on Green Flashing Top N A N A Low battery Red Flashing Top N A N A Critical battery...

Page 12: ...s When using MobileView the iTAG X Range has the following 3 battery levels indications High Indicates the tag has more than 75 Medium Indicates the tag has between 75 and 30 Low Indicates the tag has...

Page 13: ...ange can be charged using Extronics custom Multicharger Figure 16 Please contact Extronics for further information Figure 16 4 4 3 Variances in battery life Variances in battery life are based on usag...

Page 14: ...ard the button can be released This faster been will occur after approximately ten seconds 4 The top LED will flash red and front LEDs flash as the iTAG starts to download the new firmware This can ta...

Page 15: ...tica and Magicard printers A DESFire EV1 or EV3 RFID Cards Blank Photo ID card is shown in Figure 17 Figure 17 Once the RFID Photo ID card has been printed and the Kiss cut area has been removed the c...

Page 16: ...bjected to excessive mechanical or temperature stresses 4 8 Authorised persons The iTAG X Range is provided ready assembled and must not be disassembled by the user Only persons trained for the purpos...

Page 17: ...ressive ingredients that can affect the iTAG X Range s materials We recommend that you do not use compounds containing Combinations of isopropyl alcohol and dimethyl benzyl ammonium chloride Combinati...

Page 18: ...18 5 EU Declaration of Conformity...

Page 19: ...19...

Page 20: ...20...

Page 21: ...Explosive Atmospheres Part 0 Equipment General Requirements 2019 03 26 UL 60079 11 Ed 6 Explosive Atmospheres Part 11 Equipment Protection by Intrinsic Safety i 2018 09 14 CSA C22 2 NO 60079 0 2019 S...

Page 22: ...e undesired operation of the device Please see Section 8 4 of RSS Gen Issue 4 for further information This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environme...

Page 23: ...23 9 Appendix 1 Image Order reference VEL05US050 XX BB X128417 Multicharger UK X128418 Multicharger US X128437 Multicharger EU...

Reviews: