Designator
Purpose
Comments
A
Fuse Holder
Contains 1 active fuse and
1 spare. Not fitted on POE
version. See Section 3.7
B
Power input
Mains (L,N,E) or DC (+,-,E)
input, dependent on
product configuration. Not
fitted on POE version. See
Section 3.6 for details.
C
Fibre input
This can be single mode or
multimode fibre, or
replaced by a blanking
plate, depending on
product options. See
Section 3.9.3 for details
D
CAT5E input
This 10/100/1000 Base T
CAT5E data connection. It
may also be replaced by a
blanking plate, depending
on product options. See
Section 3.9.1 for details
E
Console port
This is a serial console port
for Cisco Access Points.
See 3.9.4 for details.
F
Fibre splice tray
This is a 12-way fibre
splice tray, only fitted when
the fibre option is selected.
Table 2: iRFID101 Internal Connection/Features
3.6
Power supply
Important The iRFID101 may be powered from a number of different
power sources, depending on its configuration. Refer to the
rating plate of the unit supplied for details.
Figure 7: iRFID101 Mains Power Connection
LIVE
NEUTRAL
EARTH
Use 3.5mm x 0.6mm
slotted screwdriver,
0.5-0.6Nm
Summary of Contents for iRFID101
Page 1: ...INSTALLATION AND OPERATING MANUAL iRFID101 ...
Page 22: ...iRFID101 Installation and Operating Manual 22 5 Technical Data ...
Page 24: ...iRFID101 Installation and Operating Manual 24 7 Type Codes ...
Page 25: ...iRFID101 Installation and Operating Manual 25 8 EU Declaration of Conformity ...
Page 26: ...iRFID101 Installation and Operating Manual 26 ...