Extron electronics YCS 100 User Manual Download Page 12

YCS 100 • Installation and Operation

Installation and Operation, cont’d

2-10

YCS 100 • Installation and Operation

 

2-11

Extron
PMK 350

Multi-product Projector
Mounting Kit

Cover Sheet

Front Plate

Rear Plate

U-bolt

L-shaped
Bracket

Contoured
Base

Extron
Power Supply

Extron
YCS 100

Transcoder

        

Figure 2-10 — Projector-mounting the YCS 100 
using the PMK 350 Projector Mount Kit

7

Align the two slotted holes in the bottom of the L-shaped 
bracket with the two slotted holes in the base of the 
PMK 350, on either side of the opening for the pole.  
Attach the L-bracket to the base by inserting two provided 
6-32 x 5/16" screws through the aligned slots.

8

Insert the two legs of the provided square U-bolt through 
the following parts in the order they are listed below:

a

.  The slotted holes on the back side of the bracket mount 

plate

b

.  The round holes in the rubberized contour base

c

.  The round holes in the L-shaped bracket

• 

For a typical (1.5" to 2.0" diameter) pole

 — You can use 

the supplied square U-bolt, which fi ts a typical ceiling 
pole.

• 

For a smaller pole

 — Locally obtain a square U-bolt 

that fi ts your ceiling pole.  The slotted holes on the 
bracket can accommodate a square U-bolt for pole sizes 
from 1.0" to 2.0" in diameter.

9

Move the PMK 350 up to the desired location on the ceiling 
pole, as close to the ceiling as desired. 

3

. Affi x the supplied rubber pad to the side of the U-bolt 

clamping plate that the projector pole contacts.

4

Place the U-bolt around the ceiling pole and insert the two 
legs of the U-bolt through the slotted holes on the bracket’s 
mounting plate, then through the round holes on the 
backing brace.

• 

For a typical (1.5" to 2.0" diameter) pole

 — You can use 

the supplied square U-bolt, which fi ts a typical ceiling 
pole.

• 

For a smaller or larger pole

 — Locally obtain a square 

U-bolt that fi ts your ceiling pole.  The slotted holes on 
the bracket can accommodate a square U-bolt for pole 
sizes from 1.0" to 2.5" in diameter.

5

Secure the bracket to the U-bolt with the included hex 
nuts, washers, and lock washers.  Tighten the hex nuts just 
enough that they can be loosened by hand.

Using the PMK 350 Projector Mount Kit

The PMK 350 Low Profi le Projector Mount Kit is an above-
projector mounting kit that attaches to a 1" to 2" diameter 
projector mounting pole.  It can hold more than one device, 
in a variety of sizes.  The PMK 350 is available in black 
(part #70-563-02) or white (part #70-563-03).

Follow these steps to mount the YCS 100 on the PMK 350 
bracket as follows:

1

Remove the front and back panels from the 
PMK 350, using an Extron Tweeker or other small Philips 
screwdriver.  (Retain the screws to reattach the plates when 
you are fi nished.)

2

Remove any rubber feet from the bottom of the YCS 100.

3

Secure the YCS to one side of the mounting bracket, 
using two of the supplied 4-40 x 3/16" screws in opposite 
(diagonal) corners.

4

Using the two included tie wraps, strap the YCS power 
supply to the PMK 350 bracket.

5. 

Place the bracket around the projector ceiling mounting 
pole as shown in fi gure 2-10.

6

Place the rubberized contoured base against the pole and 
opposite the back plate.  The pole should fi t snugly into the 
depression in the center of the contoured base.

     

Summary of Contents for YCS 100

Page 1: ...mersfoort The Netherlands 31 33 453 4040 Fax 31 33 453 4050 Extron Electronics Asia 135 Joo Seng Road 04 01 PM Industrial Building Singapore 368363 65 6383 4400 Fax 65 6383 4664 Extron Electronics Jap...

Page 2: ...n Wartung Alle Wartungsma nahmen sollten nur von qualifiziertem Servicepersonal durchgef hrt werden Die internen Komponenten des Ger tes sind wartungsfrei Zur Vermeidung eines elektrischen Schocks ver...

Page 3: ......

Page 4: ...ack mounting 2 4 Furniture mounting 2 6 Projector mounting 2 7 Using the PMK 100 Mini Projector Mount Kit 2 7 Using the PMK 300 Projector Mount Kit 2 8 Using the PMK 350 Projector Mount Kit 2 10 Rear...

Page 5: ...ii YCS 100 Table of Contents Table of Contents cont d YCS 100 1 Chapter One Introduction About this Manual About the YCS 100 Features Application Diagram...

Page 6: ...Transcoder has a composite video to S video luminance Y and chrominance C decoder and an S video to composite video encoder in one product The high performance digital decoder has a time base stabiliz...

Page 7: ...0 Introduction Introduction cont d 1 4 YCS 100 2 Chapter Two Installation and Operation Installation Overview Mounting the YCS 100 Rear Panel Wiring the Power Connector Front Panel Operation Troublesh...

Page 8: ...or later in this chapter 4 Apply power to the YCS 100 and to the input and output devices Mounting the YCS 100 The YCS 100 can be set on a table mounted on a rack shelf mounted under a desk podium or...

Page 9: ...1 3 OU TPU T 2 2 1 3 GREEN RED BLUE SEQ 100 15HD Figure 2 5 Mounting the YCS 100 to a back rack support 6 Deep Rack Shelf Front false faceplate uses 2 screws 1 2 Rack Width Front False Faceplate Use 2...

Page 10: ...inserting the mounting bolt through the bracket s slotted hole Furniture mounting To furniture mount the YCS 100 use the optional MBU 123 VersaTools under desk mounting kit part 70 212 01 as follows...

Page 11: ...le passing through the center Using the PMK 300 Projector Mount Kit The PMK 300 Multi Product Projector Mount Kit 70 374 01 mounts up to three quarter rack width products to a projector ceiling mount...

Page 12: ...e two legs of the U bolt through the slotted holes on the bracket s mounting plate then through the round holes on the backing brace For a typical 1 5 to 2 0 diameter pole You can use the supplied squ...

Page 13: ...ector 0 2 5 mm MAX SECTION A A Ridges Smooth A A Tie Wrap Figure 2 12 Power connector wiring 10 Secure the L shaped bracket to the square U bolt using the included hex nuts washers and lock washers Ti...

Page 14: ...ile also passing an unconverted signal to an S video monitor connected to the S video mini DIN loop through connector If problems are encountered ensure that all cables are routed and connected proper...

Page 15: ...jumper This shunt is used to enable the jumper in step 4 4 Enable close the CR8 jumper by placing the shunt on both prongs as shown below Open Closed Figure 2 16 Enabling the CR8 jumper 5 Replace the...

Page 16: ...er input requirements 12 VDC 0 3 A Temperature humidity Storage 40 to 158 F 40 to 70 C 10 to 90 noncondensing Operating 32 to 122 F 0 to 50 C 10 to 90 noncondensing Specifications N The YCS 100 includ...

Page 17: ...desk mounting bracket kit 70 212 01 PMK 100 Mini Projector Mounting Kit 70 217 01 PMK 300 Multi Product Projector Mounting Kit 70 374 01 PMK 350 Low Profile Projector Mounting Kit 70 563 02 03 Mini H...

Page 18: ...YCS 100 Specifications Part Numbers and Accessories Specifications Part Numbers Accessories cont d A 6...