Rack mounting

For optional rack mounting, do not install the rubber feet.
Mount the YCV 100, VYC 100N, or YCV 100P, on a VersaTools

rack shelf (RSF 123, Extron part #60-190-20; RSB 123,
part #60-604-21), or on a 6" deep rack shelf (RSU 126,
part #60-190-10; RSB 126, part #60-604-11), or on a 1U universal
rack shelf (RSU 129, part #60-190-01; RSB 129, #60-604-02).

On the standard rack shelf, the YCV 100, VYC 100N, and
VYC 100P mount in one of eight locations to the rear of the
shelf or in one of eight locations to the front of the shelf.

1

.

Remove rubber feet if they were previously installed on
the bottom of the unit.

2

.

Mount the unit on the rack shelf, using two 4-40 x 3/16"
screws in opposite (diagonal) corners to secure the unit to
the shelf.

3

.

Install blank panel(s) or other unit(s) on the rack shelf.

Ver

sa

Tool

s

R

a

ck 

S

helf

Qu

a

rter R

a

ck Width

F

a

l

s

e Front F

a

ce Pl

a

te 

(2) 4-40 x 3/16"

s

crew

s

Eighth R

a

ck Width

F

a

l

s

e Front F

a

ce Pl

a

te 

DI

S

TR

IB

UT

IO

N A

MP

LIF

IE

R

Mounting the YCV 100, VYC 100N, and VYC 100P on
a VersaTools rack shelf

Mounting the YCV 100, VYC 100N, & VYC 100P

The YCV 100, VYCN, and VYC 100P  can be set on a table or
mounted on a rack shelf, under a desk or tabletop, or on a
projector mount.

Tabletop use

Four self-adhesive rubber feet are included with the YCV 100,
VYC 100N, and VYC 100P.  For tabletop use, attach one foot at
each corner of the bottom side of the unit and place the unit in
the desired location.

UL rack mounting guidelines

The following Underwriters Laboratories (UL) guidelines
pertain to the safe installation of the YCV 100, VYC 100N, and
VYC 100P in a rack.

1

.

Elevated operating ambient temperature

 — If installed in

a closed or multi-unit rack assembly, the operating
ambient temperature of the rack environment may be
greater than room ambient temperature.  Therefore,
install the unit in an environment compatible with the
maximum ambient temperature (Tma = +122 °F, +50 °C)
specified by Extron.

2

.

Reduced air flow

 — Install the equipment in a rack so that

the amount of air flow required for safe operation of the
equipment is not compromised.

3

.

Mechanical loading

 — Mount the equipment in the rack

so that a hazardous condition is not achieved due to
uneven mechanical loading.

4

.

Circuit overloading

 — Connect the equipment to the

supply circuit and consider the effect that circuit
overloading might have on overcurrent protection and
supply wiring. Appropriate consideration of equipment
nameplate ratings should be used when addressing this
concern.

5

.

Reliable earthing (grounding)

 — Maintain reliable

grounding of rack-mounted equipment. Pay particular
attention to supply connections other than direct
connections to the branch circuit (e.g. use of power strips).

2-2

Summary of Contents for VYC 100N

Page 1: ...3 1797 FAX Extron EMEA 800 3987 6673 Inside Europe Only 31 33 453 4040 31 33 453 4050 FAX Extron Asia 800 7339 8766 Inside Asia Only 65 6383 4400 65 6383 4664 FAX Extron Japan 81 3 3511 7655 81 3 3511...

Page 2: ...den Stromunterbrechung Um das Ger t auf sichere Weise vom Netz zu trennen sollten Sie alle Netzkabel aus der R ckseite des Ger tes aus der externen Stomversorgung falls dies m glich ist oder aus der W...

Page 3: ...equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operatio...

Page 4: ...ack mounting 2 3 Back of the rack installation 2 4 Furniture mounting 2 5 Projector mounting 2 6 Front Panel Features 2 6 Rear Panel Features and Cabling 2 7 YCV 100 2 7 VYC 100N and VYC 100P 2 8 Trou...

Page 5: ...YCV 100 VYC 100N VYC 100P Table of Contents Table of Contents cont d YCV 100 VYC 100N and VYC 100P 1 Chapter One Introduction About the YCV 100 VYC 100N and VYC 100P Features ii...

Page 6: ...als on two female BNC connectors and or one 4 pin mini DIN connector All units include an external 12 V power supply that accepts 100 240 VAC 50 60 Hz input Features Furniture projector and rack mount...

Page 7: ...a projector mount Tabletop use Four self adhesive rubber feet are included with the YCV 100 VYC 100N and VYC 100P For tabletop use attach one foot at each corner of the bottom side of the unit and pl...

Page 8: ...ocation of the screw holes of the bracket on the mounting surface 4 Drill 3 32 2 mm diameter pilot holes 1 4 6 3 mm deep in the mounting surface at the marked screw locations 5 Insert 8 wood screws in...

Page 9: ...could damage the power supply and the YCV 100 Identify the power cord negative lead by the ridges on the side of the cord or a black heat shrink wrapping around it Power Supply Output Cord SECTION A A...

Page 10: ...t a composite video source to this female BNC connector 2 Output connectors Connect an S video output device to the two female BNC connectors and or the 4 pin mini DIN connector 3 Power connector An e...

Page 11: ...and their solutions include the following Problem No power at unit Solution Verify that the unit is receiving power by checking the front or rear LED If no LED is lit check the DC power plug terminati...

Page 12: ...pping weight 1 lbs 1 kg Vibration ISTA 1A in carton International Safe TransitAssociation Listings UL CUL Compliances CE FCC Class A VCCI AS NZS ICES MTBF 30 000 hours Warranty 3 years parts and labor...

Page 13: ...cord 3 5 mm 2 pole captive screw connector Tweeker small screwdriver User s Manual Optional Accessories These items can be ordered separately Accessories Part number Mini under desk mounting bracket 7...

Reviews: