background image

User’s Manual

Extron Electronics, USA

1230 South Lewis Street
Anaheim, CA 92805
USA
714.491.1500  
Fax 714.491.1517

Extron Electronics, Europe

Beeldschermweg 6C
3821 AH Amersfoort
The Netherlands
+31.33.453.4040  
Fax +31.33.453.4050

Extron Electronics, Asia

135 Joo Seng Road, #04-01
PM Industrial Building
Singapore 368363
+65.6383.4400  
Fax +65.6383.4664

Extron Electronics, Japan

Daisan DMJ Building 6F
3-9-1 Kudan Minami
Chiyoda-ku, Tokyo 102-0074 Japan 
+81.3.3511.7655  
Fax +81.3.3511.7656

www.extron.com

© 2003  Extron Electronics.  All rights reserved.

HIgh Resolution Video, Composite Video, and Stereo Audio

Twisted Pair Cable Transmission Products

TP Receivers Family

CAUTION

Do not connect this device to a computer data or
telecommunications network

68-547-02 

Rev. G

Printed in the USA

08 03

Summary of Contents for TP R 15 HD A

Page 1: ...uilding Singapore 368363 65 6383 4400 Fax 65 6383 4664 Extron Electronics Japan Daisan DMJ Building 6F 3 9 1 Kudan Minami Chiyoda ku Tokyo 102 0074 Japan 81 3 3511 7655 Fax 81 3 3511 7656 www extron c...

Page 2: ...artung Alle Wartungsma nahmen sollten nur von qualifiziertem Servicepersonal durchgef hrt werden Die internen Komponenten des Ger tes sind wartungsfrei Zur Vermeidung eines elektrischen Schocks versuc...

Page 3: ...7 Rack mounting TP R BNC A TP R BNC AV TP R 15HD A 2 7 Furniture mounting 2 9 Projector mounting 2 10 Rear panel features and cabling 2 11 Transmitted signal cabling 2 11 Output cabling 2 12 Computer...

Page 4: ...tion About the TP Receivers Features Appendix Specifications Accessories and Part Numbers A 1 Specifications A 2 Included Parts A 5 Accessories A 6 Cables Adapters A 6 68 547 02 Rev G Printed in the U...

Page 5: ...1024 x 768 300 feet 1280 x 1024 200 feet 1600 x 1280 100 feet Recommended transmission ranges at 60 Hz all others Video format Maximum range Composite video and audio 1000 feet Component video and S v...

Page 6: ...s composite video on one BNC connector RJ 45 connector Allows attachment to an Extron TP transmitter Cable length compensation Allows you to select whether to compensate for long cable runs automatica...

Page 7: ...vers Introduction Introduction cont d TP Receivers 2 Chapter Two Installation and Operation Installation Overview Front Panel Controls and Indicators Troubleshooting 1 6 This page was intentionally le...

Page 8: ...he cable s between the TP transmitter s and the receiver See Transmitted signal cabling in this chapter and refer to the TP Transmitters Family User s Manual part 68 546 01 6 Connect the output cables...

Page 9: ...that pin 1 is jumpered to pin 2 6 Reinstall the video board replace the cover and reinstall the screws and BNC connector hex nuts Video DIP switch The TP R 15HD A receiver can be configured to receiv...

Page 10: ...n the composite video printed circuit board See figure 2 2 a For compatibility with redesigned modified receivers and the TPX 88 A ensure that pin 1 is jumpered to pin 2 on both jumper locations b For...

Page 11: ...helf Furniture mounting All of the receiver models can be mounted under furniture such as a table or podium surface using the appropriate optional mounting bracket Extron s Mini Under Desk Mounting Ki...

Page 12: ...other models Secure the receiver to a projector mount or other surface by inserting the mounting bolt through the bracket s slotted hole figure 2 6 A A V OUTPUT OUTPUT POWER 15V 5A DC L R B AV INPUT V...

Page 13: ...site video use the R G and or B BNC R or or G B H HV V The H HV and V BNCs only output sync not video signals 4 RGB Output 15HD TP R 15HD A Connect the desired video output device to the rear panel ou...

Page 14: ...ord into this connector to connect the TP R BNC AV to a 100 to 240VAC 50 Hz or 60 Hz power source If the distance between the transmitter and receiver is too great for the receiver to power the transm...

Page 15: ...AT 5e cable in A V applications The design of Extron s skew free A V UTP cable minimizes pair skew to the point that equalization is not required Skew exists between pairs when the physical length of...

Page 16: ...Auto position the receiver automatically adjusts the level and peaking to compensate for long cable runs In the Manual position you can manually compensate for long cable runs using the level and pea...

Page 17: ...off the edge of the screen adjust the transmitter s H Shift control DDSP disables the horizontal shift control 3 Place the receiver s Manual Auto switch to manual and adjust the level and peaking cont...

Page 18: ...nnectors 1 or 2 shielded RJ 45 female Frequency response 20 Hz to 20 kHz 0 05dB THD Noise 0 03 1 kHz 0 3 20 kHz at rated maximum output drive S N 63dB at nominal level Crosstalk 80dB 1 kHz fully loade...

Page 19: ...t weight TP R BNC A 1 6 lbs 0 7 kg TP R BNC AV 2 6 lbs 1 2 kg TP R 15HD A 0 4 lbs 0 2 kg TP R AV 0 9 lbs 0 4 kg Shipping weight TP R BNC A 4 lbs 1 8 kg TP R BNC AV 5 lbs 2 3 kg TP R 15HD A 2 lbs 0 9 k...

Page 20: ...Free Plenum 26 570 04 35 Skew Free Plenum 26 570 05 50 Skew Free Plenum 26 570 06 75 Skew Free Plenum 26 570 07 100 Skew Free Plenum 26 570 08 Skew Free A V cable RJ 45 jacks Part number 150 Skew Free...

Page 21: ...TP Receivers Specifications Accessories and Part Numbers Specifications Accessories and Part Numbers cont d A 8 This page was intentionally left blank...

Reviews: