Network Port Requirements and Licensed Third-Party Software
For information about network port requirements and licensed third-party software for the
touchpanels described in this guide, please refer to the
Extron Control Product Network
Ports and Licenses Guide
, which is available at
.
Reset Modes
The TLI Pro 201 has three reset modes that are initiated by pressing the Reset button:
•
•
•
•
Enable or Disable the DHCP Client
The Reset button is found on the rear panel (see
,
Use Factory Firmware
Purpose and Notes
Use this mode to temporarily boot up the unit with factory installed firmware for a single
power cycle in the event that a firmware update has failed or if incompatibility issues arise
with user-loaded firmware.
Activation
To start the
Use
Factory
Firmware
reset mode and replace firmware:
1.
Remove power to the TLI Pro 201.
2.
On the TLI Pro 201, hold down the recessed
R
(reset) button while applying power to
the unit. When power is restored, the Power LED lights. Hold the reset button for a
further 2 seconds before releasing it. The TLI Pro 201 enters factory firmware mode.
3.
Upload new firmware to the unit as desired (see
NOTE:
Do not operate the interface firmware version that results from the reset.
If you want to use the factory default firmware, you must upload that version
again (see
)
.
Result
The TLI Pro 201 reverts to the factory installed firmware. Event scripting does not
start if the unit is powered on in this mode. All user files and settings such as drivers,
adjustments, and IP settings are maintained.
NOTE:
To return the unit to the firmware version that was running prior to the reset,
cycle power to the unit.