background image

SW4 3G HD-SDI • Serial Communication

Serial Communication

3-2

Setting Up RS-232 Communication

The SW4 3G HD-SDI switcher can be configured and controlled 

by SIS (Simple Instruction Set) commands via the switcher’s 

RS-232 port.  This port is used to connect the switcher to a host 

or external controlling device, such as a computer or control 

system, that can generate the proper command codes and 

recognize the switcher’s responses.
Wire the RS-232 connector as shown below.

Switcher

Receiv

e

Tr

ansmit Ground

RS-232

Tx Rx

DB9 connector (female)

pinout to control equipment

Computer

5

1

9

6

Pin

RS-232

Function

1

2

RX

Receive data (+)

3

TX

Transmit data (–)

4

5

Gnd

Signal ground

6

7

8

9

RS-232 connector wiring

The serial port has the following RS-232 protocol:
•   9600 baud
•   1 stop bit
•   No parity
•   8 data bits

Using Simple Instruction Set (SIS) Commands

Host-to-switcher communications

The Extron Simple Instruction Set (SIS) commands consist of 

one or more characters per field.  No special characters are 

required to begin or end a command character sequence.  When 

a command is valid, the switcher executes the command and 

sends a response to the host device.  All responses from the 

switcher to the host end with a carriage return and a line feed 

(CR/LF = 

]

), which signals the end of the response character 

string.  A string is one or more characters.

Summary of Contents for SW4 3G HD-SDI

Page 1: ...User s Manual Multi rate SDI Switcher 68 1571 01 Rev A 07 08 SW4 3G HD SDI ...

Page 2: ...faufmerksam machen daß im Inneren des Gehäuses dieses ProduktesgefährlicheSpannungen dienichtisoliert sind und die einen elektrischen Schock verursachen können herrschen Achtung Lesen der Anleitungen Bevor Sie das Gerät zum ersten Mal verwenden sollten Sie alle Sicherheits und Bedienungsanleitungen genau durchlesen und verstehen Aufbewahren der Anleitungen Die Hinweise zur elektrischen Sicherheit ...

Page 3: ...Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation The Class A limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates ...

Page 4: ......

Page 5: ...d 2 output identical signals Step 5 If the switcher is to be connected to a computer or host controller for remote control wire the provided 3 pole captive screw connector to an RS 232 cable Connect the cable to the RS 232 port on the switcher s rear panel and to the host s RS 232 port see the serial port pinout on the next page The RS 232 port has the following protocol 9600 baud No parity 1 stop...

Page 6: ... normal Choose auto input switch mode d to automatically switch to the highest numbered input with active sync pulses Choose normal mode c to manually change the input For details on how to change modes see Selecting Auto input Switch Mode in chapter 2 Installation and Operation Step 2 Select an input If you are using normal mode select the desired input by pressing and releasing its input button ...

Page 7: ...er automatically switches to the highest numbered active input N Outputs 1 and 2 output an identical signal Step 3 If needed you can create a remote connection via RS 232 see chapter 3 Serial Communication AUTO SWITCH ACTIVE SW4 3G HD SDI MULTI RATE SDI SWITCHER 1 MODE 2 NORMAL 3 AUTO 4 RATE NOT RECOGNIZED 270 Mbps 1 485 Gbps 2 97 Gbps 1 7 3 2 5 4 6 ...

Page 8: ...SW4 3G HD SDI Quick Start Guide Quick Start Guide SW4 3G HD SDI cont d QS 4 ...

Page 9: ...ocking the Front Panel 2 8 Resetting 2 8 Chapter Three Serial Communication 3 1 Setting Up RS 232 Communication 3 2 Using Simple Instruction Set SIS Commands 3 2 Host to switcher communications 3 2 Switcher initiated messages 3 3 Error responses 3 3 Timeout 3 3 Using the command response table 3 4 Symbol definitions 3 4 Command response table for SIS commands 3 5 Updating the Firmware 3 8 Download...

Page 10: ...ii SW4 3G HD SDI Table of Contents Table of Contents cont d 68 1571 01 Rev A 07 08 All trademarks mentioned in this manual are the properties of their respective owners ...

Page 11: ...SW4 3G HD SDI 1 Chapter One Introduction About this Manual Features ...

Page 12: ...e sync pulses present Executive mode is available to lock out the front panel as a security measure Features Switches video signals of all common serial digital data rates up to 3G SDI Inputs four inputs on female BNC connectors for SDI HD SDI or 3G SDI digital component video Input equalization each input is equalized regardless of its rate Outputs two parallel outputs on female BNC connectors fo...

Page 13: ...0V 0 2A 50 60H z IN PU TS 1 2 1 2 3 4 OU TP UT S RS 232 SW 4 3G HD S DI HD SDI Monitor Extron SW4 3G HD SDI Multi Rate SDI Switcher HD SDI Projector Control System HD SDI Cameras HD SDI VTR Application diagram for the SW4 3G HD SDI switcher ...

Page 14: ...SW4 3G HD SDI Introduction Introduction cont d 1 4 ...

Page 15: ...HD SDI 2 Chapter Two Installation and Operation Installation Overview Rack Mounting Rear Panel Connections Front Panel Controls and Indicators Selecting Auto input Switch Mode Locking the Front Panel Resetting ...

Page 16: ...an be mounted on a rack shelf or placed on a tabletop For optional rack mounting use any of the following rack shelves 1U 6 deep Universal Rack Shelf Kit part 60 190 10 RSU 126 1U 6 deep Basic Rack Shelf part 60 604 11 RSB 126 1U 9 5 deep Universal Rack Shelf Kit part 60 190 01 RSU 129 1U 9 5 deep Basic Rack Shelf part 60 604 02 RSB 129 UL rack mounting guidelines The following Underwriters Labora...

Page 17: ...tion to supply connections other than direct connections to the branch circuit e g use of power strips Rack mounting instructions For optional rack mounting do not install the rubber feet Mount the switcher to a rack shelf as follows 1 If rubber feet are installed on the bottom of the unit remove them 2 Mount the switcher on the rack shelf using two 4 40 x 3 16 screws in opposite diagonal corners ...

Page 18: ...ear Panel Connections INPUTS 1 2 1 2 3 4 100 240V 5A MAX 50 60 Hz OUTPUTS RS 232 Tx Rx 1 2 3 4 SW4 3G HD SDI switcher rear panel a Power connector Plug the supplied power cord into this male IEC receptacle and into an AC outlet b SDI Inputs 1 through 4 Connect SDI HD SDI and or 3G SDI video sources to these 75 ohm female BNC connectors N Each input is equalized regardless of the rate c SDI Outputs...

Page 19: ...r bidirectional RS 232 communication Wire the connectors as shown in the following figure Switcher Receive Transmit Ground RS 232 Tx Rx DB9 connector female pinout to control equipment Computer 5 1 9 6 Pin RS 232 Function 1 2 RX Receive data 3 TX Transmit data 4 5 Gnd Signal ground 6 7 8 9 RS 232 connector wiring This port has the following RS 232 protocol 9600 baud 1 stop bit No parity 8 data bit...

Page 20: ...mal button is used with the Mode button b to select normal mode Normal is a secondary function of the Input 2 button d Auto switch button The Auto button is used with the Mode button b to select the auto input switch mode Auto is a secondary function of the Input 3 button e Input buttons 1 through 4 These buttons select inputs 1 through 4 They are also used to access auto input switch and executiv...

Page 21: ... are using normal mode select the desired input by pressing and releasing its input button on the front panel The LED for the selected input lights To switch to another input press a different input button If you are using auto input switch mode no action is necessary The switcher automatically switches to the highest numbered active input N Outputs 1 and 2 output identical signals 3 If needed cre...

Page 22: ...urn auto input switch mode off 1 Press and hold the Mode Input 1 button 2 While holding down the Mode button press and hold the Normal Input 2 button 3 Release the Mode and Normal buttons simultaneously AUTO SWITCH ACTIVE SW4 3G HD SDI MULTI RATE SDI SWITCHER 1 MODE 2 NORMAL 3 AUTO 4 RATE NOT RECOGNIZED 270 Mbps 1 485 Gbps 2 97 Gbps Turning off auto input switch mode The Auto Switch Active LED tur...

Page 23: ...the mode switch If an input button is pressed while the switcher is in executive mode all front panel LEDs flash once then the switcher reverts to the currently selected input N RS 232 communication remains enabled while the switcher is in executive mode Resetting If the switcher needs to be reset to factory defaults press the Input 1 button and hold it while applying power All front panel LEDs bl...

Page 24: ...SW4 3G HD SDI Installation and Operation Installation and Operation cont d 2 10 ...

Page 25: ...SW4 3G HD SDI 3 Chapter Three Serial Communication Setting Up RS 232 Communication Using Simple Instruction Set SIS Commands Updating the Firmware ...

Page 26: ...ipment Computer 5 1 9 6 Pin RS 232 Function 1 2 RX Receive data 3 TX Transmit data 4 5 Gnd Signal ground 6 7 8 9 RS 232 connector wiring The serial port has the following RS 232 protocol 9600 baud 1 stop bit No parity 8 data bits Using Simple Instruction Set SIS Commands Host to switcher communications The Extron Simple Instruction Set SIS commands consist of one or more characters per field No sp...

Page 27: ... is changed using the front panel buttons n is the input number Error responses When the switcher receives a valid SIS command it executes the command and sends a response to the host device If the switcher is unable to execute the command because the command is invalid or it contains invalid parameters the switcher returns an error response to the host The error response codes are E01 Invalid inp...

Page 28: ...nterchangeable and command and response examples are shown throughout the table The ASCII to HEX conversion table below is for use with the command response table ASCII to HEX Conversion Table Symbol definitions CR LF carriage return with line feed carriage return space X Input number 1 through 4 X On Off status 0 off 1 on X Switch mode 0 normal mode 1 auto input switch mode X Input rate 0 through...

Page 29: ...put 4 Video mute Mute unmute video output X B Vmt X For X 0 off 1 on Read mute status B X Show video mute status Front panel lockout Turn executive mode on 1x Exe X For X 1 front panel lockout is on 0 front panel lockout if off Turn executive mode off 0x Exe X View executive mode status X X Display front panel lockout on off status For X 1 on 0 off Mode selection Normal auto input switch mode X FX...

Page 30: ... 270 Mbps Example 0LS 1011 2 Inputs 1 3 and 4 each have a signal present Input 2 has no signal The input signal rate is 1 485 Gbps Information requests General information I InX FX Vmt X Rate X X current selected input 1 4 X current mode 1 normal 2 auto input switch X video mute status 0 off or 1 on Example I In3 F1 Vmt0 Rate1 Video is selected on input 2 V2 switcher is in normal mode F1 video mut...

Page 31: ...r to host Additional Description Updating firmware Upload firmware E Upload go Upl Upl appears after the upload is complete Resetting Reset switcher to factory settings E Zxxx Zpx Reset the unit to factory default settings except for the firmware Command response table for SIS commands continued ...

Page 32: ...of firmware for your switcher 1 Go to the Extron Web site at www extron com and click the Download tab 2 From the left sidebar menu click the Firmware link 3 On the next Download Center screen click the Download link for the SW4 3G SD HDI 4 On the next screen enter the requested information then click the Download button below 5 Follow the instructions on the rest of the download screens to save t...

Page 33: ...stem and double click on it to open it 3 Follow the instructions on the Installation Wizard screens to install the Firmware Loader on your computer Unless you specify otherwise the installer program places the Firmware Loader file FWLoader exe at c Program Files Extron FWLoader If the Extron and FWLoader folders do not yet exist in your Program Files folder the installer creates them 4 Access the ...

Page 34: ...Browse to open the Choose Firmware File window and locate the firmware file that you downloaded By default the firmware file is placed at c Program Files Extron Firmware when downloaded from the Extron site C The firmware file must have a s19 extension Uploading any other file type could cause the switcher to stop functioning ...

Page 35: ...r which shows the progress of the upload appears in the Firmware Loader window The firmware upload to the switcher may take several minutes Once the status bar has progressed fully from left to right the firmware loader resets the switcher In addition messages appear on the firmware loader window indicating when the unit is uploading the firmware then resetting itself C Do not interrupt the firmwa...

Page 36: ...fer Complete is displayed and the new firmware version number appears in the Current Unit Information field C If the Firmware Loader utility exits before the status bar has progressed completely across the indicator window the firmware may be corrupted and may no longer respond to commands 11 Click Exit to close the Firmware Loader ...

Page 37: ...SW4 3G HD SDI A Appendix A Specifications Part Numbers and Accessories Specifications Part Numbers ...

Page 38: ...500 using Extron RG6 cable 120 m 400 using Extron RG59 cable Nominal level 0 8 Vp p 10 Minimum maximum levels 0 5 V to 1 0 Vp p with no offset Impedance 75 ohms Return loss 15 dB DC 1 MHz to 1 5 GHz Video output Number signal type 2 single link SDI HD SDI or 3G SDI digital component video Connectors 2 BNC female Re clocking Automatic for 270 Mbps 1 485 Gbps 2 97 Gbps or bypassed for other rates No...

Page 39: ... 1U 6 0 deep rack shelf part 60 190 10 RSU 126 or 60 604 11 RSB 126 Enclosure type Metal Enclosure dimensions 1 7 H x 8 7 W x 6 0 D 1U high half rack wide 4 3 cm H x 22 1 cm W x 15 2 cm D Depth excludes connectors Product weight 1 lb 0 5 kg Shipping weight 2 lbs 1 kg Vibration ISTA 1A in carton International Safe Transit Association Regulatory compliance Safety CE CUL UL C tick EMI EMC CE C tick F...

Page 40: ...ries These items are optional accessories that can be used with the SW4 3G HD SDI switcher Accessories Part number RG6 non plenum bulk cable 22 098 0x RG6 plenum bulk cable 22 164 0x CTU 300 Universal Crimp Tool 100 241 02 RG6 Universal Crimp Termination Kit 100 267 02 CTU 100 Universal Compression Tool 100 181 01 RG6 Universal Compression Termination Kit 60 538 02 3 5 mm 3 pole captive screw conn...

Page 41: ...y misuse improper handling care electrical or mechanical abuse abnormal operating conditions or non Extron authorized modification to the product If it has been determined that the product is defective please call Extron and ask for an Applications Engineer at 714 491 1500 USA 31 33 453 4040 Europe 65 6383 4400 Asia or 81 3 3511 7655 Japan to receive an RA Return Authorization number This will beg...

Page 42: ...s Europe Beeldschermweg 6C 3821 AH Amersfoort The Netherlands 800 3987 6673 31 33 453 4040 FAX 31 33 453 4050 Extron Electronics Asia 135 Joo Seng Rd 04 01 PM Industrial Bldg Singapore 368363 800 7339 8766 65 6383 4400 FAX 65 6383 4664 Extron Electronics Japan Kyodo Building 16 Ichibancho Chiyoda ku Tokyo 102 0082 Japan 81 3 3511 7655 FAX 81 3 3511 7656 www extron com ...

Reviews: