6

SI 3 Speakers • Installation

6

Pull sufficient wire up through the holes in the rear plate 

(see figure 8) to allow ease of connection to the speaker 

after installation.

Do not strip and connect the wire at this time.

  

 

Pass the wires 
through the plate
access hole.

Line of Stud

 

Figure 8 — Passing the wire through the plate

7.

 

Place the wall mount assembly against the wall, aligning 

the plate mounting holes with those drilled, and secure the 

assembly with appropriate hardware (see figure 5) using a 

screwdriver with an appropriate screw bit.

8

When the assembly is securely in place, loosen the hex cap 

screw (turn counter clockwise) and rotate the front section 

back into a vertical position with the hex cap screw at the 

top.  Using the hex tool, turn the hex cap screw clockwise 

to tighten it.

9

Repeat steps 

1

 through 

8

 for the second assembly mount.

Preparing the speaker for mounting

1

If the back covers were installed previously, remove them 

by carefully inserting a flat bladed screwdriver to loosen 

the two lower locking tabs first, then one or more of the 

top tabs.  Take care not to crack or chip the cover or break 

off the locking tabs.  Lift away the cover as it comes free.

2

At this point connect an optional seismic safety cable (not 

supplied) to the rear of the speaker by looping it through 

the hole on the box bracket and securing it (see figure 9).  

Anchor the other end to a suitable secure point above the 

speaker wall assembly mount.

C

 

The safety cable should be of sufficient strength 

to support the full weight of the speaker and wall 

mount assembly combined.

N

  Ensure that the cable is long enough to allow you to 

connect the speaker wires and to manipulate the speaker 

into position on the assembly mount.

Seismic Safety Cable

Anchor this end to a

suitable secure point.

Attach cable

here and

secure it.

Figure 9 — Attaching a seismic safety cable to the 
rear of the speaker

Mounting the SI 3 speaker onto the wall mount assembly

3

Carefully lift the speaker above the wall mount assembly 

and gently slide the speaker box bracket down into the 

V-Lock groove (see figure 10) until it locks into place.

Lift the speaker up to the
wall mount assembly....

V-Lock
Groove

Box
Bracket

V-Lock

Groove

Box
Bracket

...and slide it down
into the V-lock groove.

Figure 10 — Sliding the speaker down onto the wall 
mount assembly

4.

 

Repeat steps 

through

 3

 for the second speaker, then 

proceed to "Wiring the speakers" section.

 

SI 3 Speakers • Installation

7

Summary of Contents for SI 3 System INTEGRATOR

Page 1: ...User s Guide Compact Full Range Surface Mount Speakers 68 1261 01 Rev A 11 07 SI 3 System INTEGRATOR...

Page 2: ...SI 3 speaker packaging details Pa rt No XX X XX X 01 Install 206W Ceiling Speaker 33 XX XX 01 RE V Thick Single Wall Packing Bottom Foam Speakers each plastic wrapped Hex Tool plastic wrapped Top Foam...

Page 3: ...ominal impedance 16 watts continuous pink noise 32 watts continuous program Internal driver overload protection circuit Figure 2 SI 3 speakers with front grille removed N Refer to packaging informatio...

Page 4: ...with paper cone d Grill and enclosure may be painted to match environment e Weather resistant construction f Push down spring terminals g Wall mount assembly with unique V Lock system included h Back...

Page 5: ...VE L MO NO AU DIO AU DIO LIN EO UT AU X MIX AD JU ST 42 dB TO 2 4d B L R L R L R 1 2 3 INPU TS OU TP UT S VIDE O H V B G R Y 1 2 3 INPU TS MO NITO R OU T 4 5 6 C RIGH T LE FT AM PL IFI ED OU TP UT R E...

Page 6: ...section approximately 90 degrees to the rear mounting plate as shown in figure 5 and tighten the hex cap screw to lock the front section in position This makes the next steps easier to perform Fasten...

Page 7: ...is to remain hidden behind the wall follow the stud to where the small access hole has been cut and feed about two feet of wire out through the hole into the room If necessary bend the wire behind th...

Page 8: ...e hex cap screw clockwise to tighten it 9 Repeat steps 1 through 8 for the second assembly mount Preparing the speaker for mounting 1 If the back covers were installed previously remove them by carefu...

Page 9: ...e wall mount assembly and gently slide the speaker box bracket down into the V Lock groove see figure 10 until it locks into place Lift the speaker up to the wall mount assembly V Lock Groove Box Brac...

Page 10: ...terminals at the back of the speaker and insert the wires Release the springs to secure INPUT Extron Extron Positive Wire Negative Wire Figure 11 Inserting wiring into the terminals 3 Turn on the aud...

Page 11: ...p screw until it is no longer possible to lift the speaker from the wall mount assembly 6 Replace the Extron logo pressing it firmly into place N The Extron logo can be fitted either horizontally or v...

Page 12: ...ews Replace the logo Troubleshooting Tips If you have problems with your speaker refer to the table on page 11 for the possible problem cause and remedial action If you do not see your problem listed...

Page 13: ...s are adequately high Replace suspect devices with known working devices Retry the system 3 Output poor or intermittent Damaged cables or faulty connection Check cables and connections Reconnect or re...

Page 14: ...0 to 70 C 10 to 90 noncondensing Operating 32 to 122 F 0 to 50 C 10 to 90 noncondensing Mounting Wall mountable with included V lock brackets N V lock brackets can be angled up to 20 upward 35 downwar...

Page 15: ...is Limited Warranty does not apply if the fault has been caused by misuse improper handling care electrical or mechanical abuse abnormal operating conditions or non Extron authorized modification to t...

Page 16: ...Europe Beeldschermweg 6C 3821 AH Amersfoort The Netherlands 800 3987 6673 31 33 453 4040 FAX 31 33 453 4050 Extron Electronics Asia 135 Joo Seng Rd 04 01 PM Industrial Bldg Singapore 368363 800 7339...

Reviews: