4
SF 26PT • Setup Guide (Continued)
64W
OFF
10
0 V
32W
16W
32W
16W
8W
64W
8Ω
8Ω
OFF
70
V
Adjust the Tap Selector
8.
Replace the grille.
NOTE:
Wiring is the same for all hanging methods
where PCC-2 cable is used. If it is not used, the
2-pole splicing connectors at the speaker should
be replaced with the provided 3-pole splicing
connectors. Refer to
NOTE:
Setting the tap switch is the same for all
installation metnods.
NOTE:
Follow
steps 1 through 2
section before
continuing with any of the optional mounting
methods.
NOTE:
Be sure to allow extra cable length for the
structure attachment points
Optional Ceiling Bracket Kit
The optional SMK C SF 26PT Extron Ceiling Bracket Kit
allows the SF 26PT speaker assembly to be suspended
from a octagon junction box. The kit consists of two ceiling
brackets and matching magnetic covers.
PendantConnect-2
Cable
Ceiling Bracket
Steel Cables
Speaker Wires
Cable Lock
Cable Lock
Release
Min. 1”
3-Pole Splicing
Connector
Cover Plate
Side View
1
1
2
2
3
3
3
3
4
4
4
4
2
2
Cable Lock
Cable Lock
Release
Min. 1”
Side View
3
3
4
4
2
2
Grommet
1.
Install and wire an octagon junction box where the
ceiling bracket is to be attached.
NOTE:
The junction box must be attached to a
permanent structural member of the building
and be able to support the complete speaker
assembly including the speaker and cap, cable,
and the ceiling bracket and cover plate. See the
Warning
at the beginning of this guide.
2.
Route the free end of the PCC-2 cable through the
ceiling bracket cover
1
with the magnetic side of the
cover facing the ceiling bracket.
3.
Keeping in mind how much speaker wire and steel
cable will be required, remove as much of the PCC-
2 cable jacket as necessary such that the end of the
jacket remains flush with the top of the black center
grommet
2
of the ceiling bracket.
4.
Route the free ends of the two steel support cables
through the two ceiling bracket cable locks
4
. Inserting
the steel cable through the bottom of the cable lock will
lock the cable in place. Pressing the cable lock release
will unlock the cable.
NOTE:
A minimum of 1
"
(25.4 mm) of steel cable
must protrude from the top of the cable lock.