Quantum Ultra Series Videowall Processing Systems • Reference
116
116
Ventilation
Ensure that sufficient airflow is provided to satisfy the ventilation requirements of
all
items
of equipment installed in the rack.
A ventilation gap of at least 4 inches (10 cm) must be left between the side panel vents of
the Quantum Ultra and adjacent surfaces or equipment.
Rack Mounting Procedure
The Quantum Ultra Series processors are housed in rack-mountable metal enclosures
with mounting flanges for standard 19-inch racks.
Mount the unit as follows (see
on the next page for an example):
1.
Insert the unit into the rack, aligning the holes in the mounting flanges with those in
the rack.
2.
Secure the processor to the rack using the supplied bolts.
QUANT
UM UL
TRA 610
VID
EO
W
AL
L P
RO
CE
SSO
R
OP
EN
LOCK
PR
IM
AR
Y P
OW
ER
RE
DUNDANT
PO
WE
R
FRONT
FA
NS
RE
AR
FA
NS
STA
TUS
Figure 108.
Rack Mounting the Quantum Ultra or Ultra II 610
ATTENTION:
•
Because of the weight of the Quantum Ultra Series processor, you must provide
additional support for the unit from the back.
•
Compte tenu du poids du processeur Quantum Ultra Series, vous devez fournir
plus de capacités de support à l’arrière de l’unité.