![Extron electronics PVS 305SA Setup Manual Download Page 2](http://html1.mh-extra.com/html/extron-electronics/pvs-305sa/pvs-305sa_setup-manual_2457103002.webp)
Installation
PRELIMINAR
Y
VoiceLift connector
i
VoiceLift receiver connection
— Connect an optional Extron VoiceLift IR receiver to this RJ-45 connector for integration of
the audio output of a VoiceLift Microphone system.
N
The Extron VoiceLift Microphone Kit is an optional accessory which must be purchased separately.
Paging sensor connector
j
Paging sensor input
— Connect the optional Priority Page Sensor to this port, to enable audio interrupts during paging
system use.
N
Enable the switcher’s paging sensor port, using
Global Configurator
or the
MediaLink Switchers (MLS) and PoleVault
Switchers (PVS) control software
, available at www.extron.com.
The Extron Priority Page Sensor Kit (part #
70-619-01
) is an optional accessory which must be purchased separately.
DC Vol/mute connector
k
DC Volume control port (Vol/Mute)
— This port is used to connect an Extron external volume control module, such as
a VCM, to the PVS 305SA . The range is 0 to 10 V, where 0 V is mute and 10 V is maximum volume. When connected,
the external volume control module is the sole volume controller. Connect the supplied blue, male, 3-pole captive screw
connector to this port.
N
Do not control the PVS volume via RS-232 if this port is connected to a VCM 100, or a VC 50. If a VCM is controlling the
volume, an MLC should not control audio volume via RS-232.
Power connector
a
DC power connector —
When all other cables have been connected, plug the round power jack from the 12 VDC power
source into this connector to power the switcher, the PVT wallplates, the MLC controller and, where installed, the VoiceLift
receiver. One of the five front panel input button LED is lit when the PVS 305SA is receiving power.
N
Use only the supplied 12 V, 5A power supply for this switcher.
The PVS 305SA power supply can support a typical system: for example, a PVS 305SA , 4 PVT Wallplates, 2 or 4 speakers,
an MLC 104 IP Plus with an IRCM DV+, and a VoiceLift Microphone system.
If an SCP 104 is used in the system, the MLC 104 IP Plus MUST have its own power supply.
Front Panel Operation and Configuring the PVS 305SA Switcher
For full details of front panel operation and switcher configuration, refer to the PVS 305SA User’s Manual, and the
MLC 104 IP Plus User’s Manual
.
For VoiceLift and Page Sensor installation and operation details, refer to the VoiceLift
System User’s Manual
and the Paging Sensor User’s Manual. All four manuals are available online at www.extron.com.
Front panel operation
N
See the front panel image on page 1 for the location of input buttons, encoders, LEDs, and configuration port.
• To change inputs, select an input button, 1 through 4, (video and audio), or 5 (audio only).
• To adjust audio input levels, rotate the Input encoder through 43 positions in 1 dB steps (-18 to +24 dB, default 0).
• To adjust VoiceLift microphone levels, rotate the MIC encoder through 43 positions in 1dB steps (-18 to +24 dB,
default 0).
N
Front panel LEDs indicate input and mic levels (see image at right).
On initial switcher power-up the amplifier level is automatically adjusted to 50%
• To adjust Paging sensitivity, rotate the Paging knob clockwise to increase, and
counter-clockwise to decrease sensitivity.
Configuration
The PVS 305SA switcher can be controlled by MediaLink Controller (MLC) or by an
RS-232 device acting through the MLC. Alternatively, the switcher can be set up and controlled via a host computer
or other device (such as a control system) attached to the switcher’s rear panel RS-232/MLC/IR port. The control
device (host) can use either Extron’s Simple Instruction Set (SIS
™
) commands, the Global Configurator (GC2)
program for Windows, or the
MediaLink Switchers (MLS) and PoleVault Switchers (PVS) control software
,
available at www.extron.com. See pages 1 and 2 for connection details.
N
Configuration can also be completed by connecting a 2.5 mm stereo mini cable (part #
70-335-01
) to the 2.5 mm
config. port on the front panel. This port uses the same protocol as the RS-232 port on the rear panel.
Firmware updates can be made
only
via the front panel configuration port.
R
efer to the
PVS 305SA User’s Manual for a full list of the relevant SIS commands.
N
The PVS 305SA is capable of receiving signals from PVT wallplates located up to 100 feet (30 m) away.
The optimum distance
is between 50 and 75 feet (15 and 22 m)
. The minimum distance is 15 feet (4.6 m).
Cable A carries the video signals and cable B carries the audio signal, vertical sync information and 5 VDC current from the PVS
to power the PVT wallplates.
The ports on the rear of the PVS 305SA are color coded for input number and signal type. To ensure correct cable identification
and connection during installation, a sheet of color coded cable labels is supplied. Refer to “Labeling the A/V Inputs” section in the
Polevault System Installation Manual, for details.
When connecting the TP cables to the PVS 305SA connect input 1’s cable A to the RJ-45 port labeled 1A, and input 1’s cable B to
the RJ-45 port labeled 1B. Likewise, connect input 2, 3, or 4‘s cable A to its corresponding numbered A port, and cable B to its B
port. Do not cross-connect the cables.
RJ-45 termination must comply with the TIA/EIA T 568A or 568B wiring standards for all connectors.
The same standard
MUST be used at both ends of all cables.
Refer to the
PoleVault System Installation Manual for details. The cables supplied
with the PoleVault system are terminated to the TIA 568A standard.
c
Aux audio input
— Input 5 is a dedicated audio only input for an auxiliary, stereo, line-level audio signal from an audio
output source such as a DVI/HDMI device or an MP3 player. Connect the cable from the source to this 5-pole captive
screw connector. The connector can be wired as balanced or unbalanced.
N
Input 5 is audio only. No video signals should be connected to this input.
A/V output connectors
d
RGB video output
— For RGB video, use a VGA cable to connect the projector to this female 15-pin HD connector.
e
Composite video output
— For composite video, use a cable with an RCA connector to connect the projector to this female
RCA jack.
f
Amplified Out
— Connect one speaker to each channel marked “L” and “R” (left and right) using the supplied black 4-pin
5 mm connector. Wire red to positive, black to negative. Each channel is rated for 25 W at 2, 4, or 8 Ohm loads. If using
more than one speaker per channel, connect them in parallel.
C
Do not tie both L and R outputs to each other and/or to ground
as it may short the outputs and damage the amplifier.
N
The speaker setup covers two individual speakers of 8 ohm impedance or two pairs of speakers in parallel, where each channel drives
a maximum output load of 2 ohms.
g
Line out audio port
— This port is used for connecting an Extron external amplifier, recording, podcasting, or assisted
listening devices. It can be configured via RS-232 for fixed or variable audio output (default is variable). It can be wired for
balanced or unbalanced signals.
Remote control connector
h
RS-232/MLC/IR control port
— The PVS switcher can be controlled via an RS -232 connection directly from a host computer,
a control system, or a MediaLink Controller (MLC). The MLC provides remote control of input switching and volume.
Connect a cable between this port and the MLC MediaLink Controller.
The RS-232 protocol is 9600 baud, 8-bit, 1 stop bit,
no parity, and no flow control. Refer to the
MLC 104 IP Plus User’s Manual
for full details.
MLC 104 IP Plus front and side panels
2
3
G
R
O
U
N
D
1
IR
IN
G
R
O
U
N
D
IR
O
U
T
C
M
SC
P
GR
OU
ND
GR
OU
ND
Tx
R
x
DISPLAY
RS-232/IR
LAN
PRESS TAB WITH
TWEEKER TO REMOVE
A B
MLS PWR
RS-232 12V
DIGITAL
I/O
A B C D E
COMM LINK
+V
O
U
T
G
R
O
U
N
D
Tx
R
x
+1
2V
IN
CONFIG
DISPLAY
VOLUME
MLC 104 IP PLUS
ON
VCR
DVD
PC
OFF
1
2
3
4
RS-232/MLC/IR
A B C
PVS 305SA Switcher's
rear panel
RS-232/MLC/IR port
NOTE
You must connect a ground
wire between the MLC and the
switcher.
MLC 104 IP Plus’s
MLS and power ports
NOTE
If you use cable that has a drain
wire, tie the drain wire to ground
at both ends.
D E
Tx Rx IR
+
12 V
RS-232 12V
MLS PWR
A B
Rx
Tx
GR
OUND
GR
OUND
+12V IN
Ground ( )
Transmit (Tx)
B Receive (Rx)
A
Transmit (Tx)
Receive (Rx)
B
A
+12 VDC input
50 feet (38 m) maximum
PVS 305SA Rear Panel
L
R
L
R
L
R
AUX AUDIO
INPUT 5
LINE OUT
VOICELIFT
RECEIVER
PAGING
SENSOR
DO NOT
GROUND
OR SHORT
SPEAKER
OUTPUTS
1B RGB
1A RGB
2B RGB
2A RGB
3B RGB
/VIDEO
4B RGB
/VIDEO
3A RGB
4A RGB
I
N
P
U
T
S
RS-232 MLC/IR
2/4/8
Ohms
CLASS 2 WIRING
AMPLIFIED AUDIO OUT
VOL/MUTE
Tx Rx IR
12V
10V
50mA
POWER
US
LISTED
17TT
AUDIO/VIDEO
APPARATUS
®
RGB
VIDEO
OUTPUTS
CONTROL
N15779
12V
5A MAX
RS-232
RS-232
and power
Projector
3
2
PEAK
NORMAL
SIGNAL
Signal threshold
-20 dBV (-18 dBu)
Level has been
properly adjusted
Level set too high,
lower input gain