NOTES:

  The length of exposed wires is critical. The ideal length is 3/16 inch (5 mm).

If the stripped section of wire is longer than 3/16 inch, the exposed wires may 
touch, causing a short circuit. If it is shorter than 3/16 inch, wires can be easily 
pulled out of the captive screw connectors.

Figure 5 identifies the tip, ring, and sleeve parts of standard audio connectors. A mono 
audio connector consists of the tip and sleeve. A stereo audio connector consists of the tip, 
ring and sleeve. The tip, ring, and sleeve wires are also shown on the captive screw audio 
connector diagrams.

Tip (+)

Sleeve (   )

Sleeve (   )

Ring (-)

Tip (+)

RCA Connector

3.5 mm Stereo Plug Connector

(balanced)

Figure 5. 

Typical Audio Connectors

c

 

RJ-45 connector —

 

 

MTP T AV board —

 Connect the transmitter to a 

suitable MTP receiver via this connector. Terminate 
the cable as shown on the right, using the same 
standard (A or B) at both ends 

MTP R AV board —

 Connect the twisted pair 

cable from the transmitter to this input connector. 
Terminate the cable as shown on the right, using 
the same standard (A or B) at both ends

d

 

Power LED —

 This LED lights to indicate that 

power is applied to the board.

e

 

Sharpness and Gain Adjustment (MTP R AV only) —

 Image sharpness and gain can 

be adjusted with these two potentiometers for optimizing the image and signal quality. 
View the image and adjust the either control for the best image quality.

5

Pin

1

2
3

6
7
8

4

Wire color

White-green

Green
White-orange

White-blue

Orange
White-brown
Brown

Wire color

T568A

T568B

White-orange

Orange
White-green

White-blue

Green
White-brown
Brown

Blue

Blue

Insert Twisted
Pair Wires

Pins:

12345678

RJ-45 

Connector

 

PowerCage MTP T AV and PowerCage MTP R AV • Installation and Operation

5

Summary of Contents for PowerCage MTP AV Series

Page 1: ...68 1643 01 Rev A 08 10 MTP Twisted Pair Transmitter and Receiver Modular Boards PowerCage MTP AV Series User Guide PowerCage Products...

Page 2: ...rksam machen da im Inneren des Geh uses dieses Produktes gef hrliche Spannungen die nicht isoliert sind und die einen elektrischen Schock verursachen k nnen herrschen Achtung Lesen der Anleitungen Bev...

Page 3: ...with the instruction guide may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will...

Page 4: ...3 Installing the Boards into the PowerCage Enclosure 3 Connections LEDs and Encoders 4 PowerCage Front Panel Port Control and Indicators 6 Operation 7 Reference Information 8 Specifications 8 Part Num...

Page 5: ...ted Pair boards that are exclusively for use in Extron PowerCage 1600 enclosure They can be used with any CAT 5 5e or 6 cable or with Extron Enhanced Skew Free A V UTP cable for cable runs of 1 000 fe...

Page 6: ...Hot swappable components allow the user to replace boards or install additional transmitter and receiver boards any time for quick and easy upgradeability or expansion without the need to power down t...

Page 7: ...able remove as many blank plates or previously installed boards from the rear of the PowerCage as necessary for the number of new boards to be installed 2 Hold the board with the signal connectors tow...

Page 8: ...ect suitable display devices to the BNC connectors for composite video Vid or S video output Y C b Audio connector 5 pole captive screw MTP T AV board Connect an audio input source to the 5 pole capti...

Page 9: ...o a suitable MTP receiver via this connector Terminate the cable as shown on the right using the same standard A or B at both ends MTP R AV board Connect the twisted pair cable from the transmitter to...

Page 10: ...h fiber optic boards only where installed This LED lights to indicate that light is received on the fiber optic board Rx connector at this location i Comm Select button Repeatedly press this button to...

Page 11: ...powered up the system is fully operational If any problems are encountered verify that the cables are routed and connected properly and that all display devices have suitable resolutions and refresh r...

Page 12: ...V to 1 5 Vp p with no offset Impedance 75 ohms Return loss 30 dB DC 10 MHz DC offset max allowable 250 mV Video output PowerCage MTP R AV Number signal type 1 S video or composite video Connectors 2...

Page 13: ...e 6 shielded or unshielded Power consumption Each MTP board at 115 VAC 60 Hz MTP T AV 2 69 watts MTP R AV 3 92 watts Power input requirements 12 VDC 1 0 A supplied by the PowerCage enclosure Temperatu...

Page 14: ...Accessory Part number Enhanced Skew Free A V UTP cable 26 569 0x Enhanced Skew Free A V cable 1000 ft non plenum 22 141 03 Skew Free UTP P series A V cable 75 ft 22 8m 26 570 07 Enhanced Skew Free A...

Page 15: ...Hanzeboulevard 10 3825 PH Amersfoort The Netherlands China Extron China 686 Ronghua Road Songjiang District Shanghai 201611 China Asia Extron Asia 135 Joo Seng Road 04 01 PM Industrial Bldg Singapore...

Reviews: