MVC 121 • Remote Control
MVC 121 • Remote Control
Remote Control, cont’d
3-6
3-7
Command
ASCII Command
Response
Additional description
(host to controller)
(controller to host)
Command
ASCII Command
Response
Additional description
(host to controller)
(controller to host)
Master Output volume control
(see
Gain/volume adjustment note
on page 3-7)
Specify a volume setting**
X1
V/v
V
o
l
X1
Set the output volume to
X1
.
Increment volume**
+V/v
V
o
l
X1
Increment the volume in 1 dB steps.
Decrement volume**
-V/v
V
o
l
X1
Decrement the volume in 1 dB steps.
V
iew output volume level**
V
/
v
X1
Show the output volume.
Front panel security lockout (executive mode)
Set executive mode**
X8
X/x
Exe
X8
Set executive mode to
X8
where 0 = off, 1 =
mode 1, and 2= mode 2. See
Front panel security
lockout (executive mode)
in chapter 2.
V
iew executive mode status**
X
/
x
X8
Show executive mode status.
Information request
Request general info**
I/
i
X9
Show rear panel DIP switch settings, where
X8
=
16 possible DIP switch setting (0 – 15). See the
DIP switch settings tables under
Symbol
definitions
in this chapter
.
Request for part number
Request for part number**
N
/
n
60-572-01
Show the MVC 121 part number
.
Input gain control
(see
Gain/volume adjustment note
on page 3-7)
Set gain (+dB)
X2
*
X5
GI
n
X2
•Gain
X4
Set the gain of input
X2
to
X4
.
Set attenuation (-dB)
X2
*
X6
gI
n
X2
•Gain
X4
Set the attenuation of input
X2
to
X4
.
Increment gain**
X2
+G/g
In
X2
•Gain
X4
Increment the gain of input
X2
in 1 dB steps.
Decrement gain**
X2
-G/g
In
X2
•Gain
X4
Decrement the gain of input
X2
in 1 dB steps.
V
iew input gain level**
X2
G/g
X4
Show the gain
X4
of input
X2
.
** These commands use both uppercase and lowercase characters, e.g., X or x (X/x), I or i (I/i), etc.
Update firmware
Upload firmware
Esc
Upload
Go
See Note below
.
Upload success
U
P
L
See Note below
.
Firmwar
e updates will periodically become available on the Extr
on W
eb site. T
o update the firmwar
e, first download the
update file fr
om the site. Then open HyperT
erminal and type the
Esc
Upload
command. After r
eceiving the Go
r
esponse,
select Send T
ext File fr
om the T
ransfer menu. In the Send T
ext File window
, locate and select the file you downloaded and
click Open. The controller will send the UPL
response once the update has been successfully completed. It will send the
error code E23 if the update failed.
Query software version
Query software version**
Q
/
q
X7
Show the MVC’s firmware version.
System reset
Reset to factory default
Esc
ZXXX
Zpx
Note:
factory default should be as follows:
Master output volume:
X1
= 50 (-30 dB).
All input volume:
X5
= 0 dB.
Gain/volume adjustment note:
All front panel gain/volume adjustments are in
0.5 dB
increments whenever the knobs are turned
slowly
. However
, the SIS messages (RS-232) that the MVC sends to the host ar
e in
1 dB
increments
only
. The MVC treats each 0.5 dB gain/volume increment between two consecutive
whole dB units as the lower of the two units. As shown in the table examples, in a continuous
adjustment sequence, the SIS messages to the host will send the same value twice.
Vo
lu
m
e
Chang
e
SIS Messa
g
e
to Host
51.0
51.5
52.0
52.5
53.0
. . . .
. . . .
. . . .
. . . .
Vo
l 5
1
Vo
l 5
1
Vo
l 5
2
Vo
l 5
2
Vo
l 5
3
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201
Fax 07131 911203