MVC 121 Plus • Operation
17
Line input 3
•
Gain (GAIN)
— Stereo (left/right) gain control with a range from -18 to +24 dB includes
mute buttons. Step resolution is 0.1 dB. Left and right polarity switches
(+ or -) are provided. Gain control is provided pre-meter and mute control is provided
pre-meter. A Gang switch ties the two input levels together.
Figure 21.
Stereo Line Gain
•
Filter (FILT)
— Up to three filters can be inserted in any combination of High Pass, Low
Pass, Bass & Treble shelving (tone), or Parametric Equalizer.
Filter Processor Block
A filter block can be configured for each MVC input. The following functions are available:
•
Insert
—
The filter block is inserted and made active by right-clicking on the block
and selecting from the context menu or by double-clicking and entering selections.
•
Remove a filter
—
An active filter can be removed by right-clicking on the
block and selecting
Delete
or by selecting the block and pressing <delete> on the
keyboard. This sets the parameters back to default and bypasses the block.
•
Bypass
—
When bypass is active, signal flow passes through the
filter block without filter processing, regardless of the settings.
When bypass is removed, the signal will be processed according
to the filter settings. A red mark appears in the lower left of the
block (shown on the right) to indicate it has been inserted, but is
currently bypassed.