background image

Precautions 

This symbol is intended to alert the user of important 

operating and maintenance (servicing) instructions in 

the literature provided with the equipment. 

This  symbol  is  intended  to  alert  the  user  of  the 

presence of uninsulated dangerous voltage within 

the product’s enclosure that may present a risk of 

electric shock. 

Caution

Read

 

Instructions • 

Read and understand all safety and operating 

instructions before using the equipment. 

Retain Instructions • 

The safety instructions should be kept for future 

reference.

Follow Warnings • 

Follow all warnings and instructions marked on the 

equipment or in the user information.

Avoid Attachments • 

Do not use tools or attachments that are not 

recommended by the equipment manufacturer because they may be 

hazardous. 

Warning

Power sources • 

This equipment should be operated only from the power source 

indicated on the product. This equipment is intended to be used with a main power 

system with a grounded (neutral) conductor. The third (grounding) pin is a safety 

feature, do not attempt to bypass or disable it. 

Power disconnection • 

To remove power from the equipment safely, remove all power 

cords from the rear of the equipment, or the desktop power module (if detachable), 

or from the power source receptacle (wall plug).

Power cord protection • 

Power cords should be routed so that they are not likely to be 

stepped on or pinched by items placed upon or against them. 

Servicing • 

Refer all servicing to qualified service personnel. There are no user-

serviceable parts inside. To prevent the risk of shock, do not attempt to service 

this equipment yourself because opening or removing covers may expose you to 

dangerous voltage or other hazards. 

Slots and openings • 

If the equipment has slots or holes in the enclosure, these are 

provided to prevent overheating of sensitive components inside. These openings 

must never be blocked by other objects. 

Lithium battery • 

There is a danger of explosion if battery is incorrectly 

replaced. Replace it only with the same or equivalent type recommended by 

the manufacturer. Dispose of used batteries according to the manufacturer’s 

instructions.

Ce  symbole  sert  à  avertir  l’utilisateur  que  la 

documentation fournie avec le matériel contient des 

instructions importantes concernant l’exploitation et 

la maintenance (réparation).

Ce symbole sert à avertir l’utilisateur de la présence 

dans le boîtier de l’appareil de  tensions dangereuses 

non isolées posant des risques d’électrocution.

Attention

Lire les instructions• 

Prendre connaissance de toutes les consignes de 

sécurité et d’exploitation avant d’utiliser le matériel.

Conserver les instructions• 

Ranger les consignes de sécurité afin de pouvoir 

les consulter à l’avenir.

Respecter les avertissements • 

Observer tous les avertissements et consignes 

marqués sur le matériel ou présentés dans la documentation utilisateur.

Eviter les pièces de fixation • 

Ne pas utiliser de pièces de fixation ni d’outils 

non recommandés par le fabricant du matériel car cela risquerait de poser 

certains dangers.

Avertissement

Alimentations• 

Ne faire fonctionner ce matériel qu’avec la source d’alimentation 

indiquée sur l’appareil. Ce matériel doit être utilisé avec une alimentation principale 

comportant un fil de terre (neutre). Le troisième contact (de mise à la terre) constitue 

un dispositif de sécurité : n’essayez pas de la contourner ni de la désactiver.

Déconnexion de l’alimentation• 

Pour mettre le matériel hors tension sans danger, 

déconnectez tous les cordons d’alimentation de l’arrière de l’appareil ou du module 

d’alimentation de bureau (s’il est amovible) ou encore de la prise secteur.

Protection du cordon d’alimentation • 

Acheminer les cordons d’alimentation de 

manière à ce que personne ne risque de marcher dessus et à ce qu’ils ne soient pas 

écrasés ou pincés par des objets.

Réparation-maintenance • 

Faire exécuter toutes les interventions de réparation-

maintenance par un technicien qualifié. Aucun des éléments internes ne peut être 

réparé par l’utilisateur. Afin d’éviter tout danger d’électrocution, l’utilisateur ne doit 

pas essayer de procéder lui-même à ces opérations car l’ouverture ou le retrait des 

couvercles risquent de l’exposer à de hautes tensions et autres dangers.

Fentes et orifices • 

Si le boîtier de l’appareil comporte des fentes ou des orifices, ceux-ci 

servent à empêcher les composants internes sensibles de surchauffer. Ces ouvertures 

ne doivent jamais être bloquées par des objets.

Lithium Batterie • 

Il a danger d’explosion s’ll y a remplacment incorrect de la batterie. 

Remplacer uniquement avec une batterie du meme type ou d’un ype equivalent 

recommande par le constructeur. Mettre au reut les batteries usagees conformement 

aux instructions du fabricant.

Safety Instructions • English

Consignes de Sécurité • 

F

rançais

Sicherheitsanleitungen • Deutsch

Dieses  Symbol  soll  dem  Benutzer  in  der  im 

Lieferumfang  enthaltenen  Dokumentation 

besonders  wichtige  Hinweise  zur  Bedienung  und 

Wartung (Instandhaltung) geben.

Dieses Symbol soll den Benutzer darauf aufmerksam 

machen,  daß  im  Inneren  des  Gehäuses  dieses 

Produktes gefährliche Spannungen, die nicht isoliert 

sind und die einen elektrischen Schock verursachen 

können, herrschen.

Achtung

Lesen der Anleitungen 

• Bevor Sie das Gerät zum ersten Mal verwenden, 

sollten Sie alle Sicherheits-und Bedienungsanleitungen genau durchlesen 

und verstehen.

Aufbewahren der Anleitungen 

• Die Hinweise zur elektrischen Sicherheit 

des Produktes sollten Sie aufbewahren, damit Sie im Bedarfsfall darauf 

zurückgreifen können.

Befolgen der Warnhinweise 

• Befolgen Sie alle Warnhinweise und 

Anleitungen auf dem Gerät oder in der Benutzerdokumentation. 

Keine Zusatzgeräte 

• Verwenden Sie keine Werkzeuge oder Zusatzgeräte, 

die nicht ausdrücklich vom Hersteller empfohlen wurden, da diese eine 

Gefahrenquelle darstellen können.

Vorsicht

Stromquellen

 • Dieses Gerät sollte nur über die auf dem Produkt angegebene 

Stromquelle betrieben werden. Dieses Gerät wurde für eine Verwendung mit einer 

Hauptstromleitung mit einem geerdeten (neutralen) Leiter konzipiert. Der dritte 

Kontakt ist für einen Erdanschluß, und stellt eine Sicherheitsfunktion dar. Diese 

sollte nicht umgangen oder außer Betrieb gesetzt werden. 

Stromunterbrechung 

• Um das Gerät auf sichere Weise vom Netz zu trennen, sollten 

Sie alle Netzkabel aus der Rückseite des Gerätes, aus der externen Stomversorgung 

(falls dies möglich ist) oder aus der Wandsteckdose ziehen.

Schutz des Netzkabels 

• Netzkabel sollten stets so verlegt werden, daß sie nicht im 

Weg liegen und niemand darauf treten kann oder Objekte darauf- oder unmittelbar 

dagegengestellt werden können.

Wartung 

• Alle Wartungsmaßnahmen sollten nur von qualifiziertem Servicepersonal 

durchgeführt werden. Die internen Komponenten des Gerätes sind wartungsfrei. 

Zur Vermeidung eines elektrischen Schocks versuchen Sie in keinem Fall, dieses 

Gerät selbst öffnen, da beim Entfernen der Abdeckungen die Gefahr eines 

elektrischen Schlags und/oder andere Gefahren bestehen.

Schlitze und Öffnungen 

• Wenn das Gerät Schlitze oder Löcher im Gehäuse aufweist, 

dienen diese zur Vermeidung einer Überhitzung der empfindlichen Teile im 

Inneren. Diese Öffnungen dürfen niemals von anderen Objekten blockiert werden.

Litium-Batterie 

• Explosionsgefahr, falls die Batterie nicht richtig ersetzt 

wird. Ersetzen Sie verbrauchte Batterien nur durch den gleichen oder einen 

vergleichbaren Batterietyp, der auch vom Hersteller empfohlen wird. Entsorgen Sie 

verbrauchte Batterien bitte gemäß den Herstelleranweisungen.

Este  símbolo  se  utiliza  para  advertir  al  usuario 

sobre  instrucciones  importantes  de  operación  y 

mantenimiento (o cambio de partes) que se desean 

destacar  en  el  contenido  de  la  documentación 

suministrada con los equipos.

Este símbolo se utiliza para advertir al usuario sobre 

la presencia de elementos con voltaje peligroso sin 

protección aislante, que puedan encontrarse dentro 

de la caja o alojamiento del producto, y que puedan 

representar riesgo de electrocución.  

Precaucion

Leer las instrucciones • 

Leer y analizar todas las instrucciones de operación y 

seguridad, antes de usar el equipo.

Conservar las instrucciones • 

Conservar las instrucciones de seguridad para 

futura consulta.

Obedecer las advertencias • 

Todas las advertencias e instrucciones marcadas 

en el equipo o en la documentación del usuario, deben ser obedecidas.

Evitar el uso de accesorios • 

No usar herramientas o accesorios que no 

sean especificamente recomendados por el fabricante, ya que podrian 

implicar riesgos. 

Advertencia

Alimentación eléctrica • 

Este equipo debe conectarse únicamente a la fuente/tipo 

de alimentación eléctrica indicada en el mismo. La alimentación eléctrica de este 

equipo debe provenir de un sistema de distribución general con conductor neutro 

a tierra. La tercera pata (puesta a tierra) es una medida de seguridad, no puentearia 

ni eliminaria. 

Desconexión de alimentación eléctrica • 

Para desconectar con seguridad la acometida 

de alimentación eléctrica al equipo, desenchufar todos los cables de alimentación 

en el panel trasero del equipo, o desenchufar el módulo de alimentación (si fuera 

independiente), o desenchufar el cable del receptáculo de la pared.

Protección del cables de alimentación • 

Los cables de alimentación eléctrica se deben 

instalar en lugares donde no sean pisados ni apretados por objetos que se puedan 

apoyar sobre ellos. 

Reparaciones/mantenimiento • 

Solicitar siempre los servicios técnicos de personal 

calificado. En el interior no hay partes a las que el usuario deba acceder. Para evitar 

riesgo de electrocución, no intentar personalmente la reparación/mantenimiento 

de este equipo, ya que al abrir o extraer las tapas puede quedar expuesto a voltajes 

peligrosos u otros riesgos. 

Ranuras y aberturas • 

Si el equipo posee ranuras o orificios en su caja/alojamiento, 

es para evitar el sobrecalientamiento de componentes internos sensibles. Estas 

aberturas nunca se deben obstruir con otros objetos.

Batería de litio • 

Existe riesgo de explosión si esta batería se coloca en la posición 

incorrecta. Cambiar esta batería únicamente con el mismo tipo (o su equivalente) 

recomendado por el fabricante. Desachar las baterías usadas siguiendo las 

instrucciones del fabricante.

Instrucciones de seguridad • Español

Extron Warranty

Extron

 

Electronics warrants this product against defects in materials and workmanship 

for a period of three years from the date of purchase.  In the event of malfunction during 

the warranty period attributable directly to faulty workmanship and/or materials, 

Extron Electronics will, at its option, repair or replace said products or components, 

to whatever extent it shall deem necessary to restore said product to proper operating 

condition, provided that it is returned within the warranty period, with proof of 

purchase and description of malfunction to:

USA, Canada, South America, 
and Central America:

Extron USA 

1001 East Ball Road 

Anaheim, CA 92805 

U.S.A.

Europe, Africa, and the Middle East:

Extron Europe 

Hanzeboulevard 10 

3825 PH Amersfoort 

The Netherlands

Asia:

Extron Asia 

135 Joo Seng Road #04-01 

PM Industrial Bldg. 

Singapore 368363 

Singapore

Japan:

Extron Japan 

Kyodo Building, 16 Ichibancho 

Chiyoda-ku, Tokyo 102-0082 

Japan

China:

Extron China 

686 Ronghua Road, Songjiang 

District 

Shanghai 201611 

China

Middle East:

Extron Middle East 

Dubai Airport Free Zone 

F12, PO Box 293666 

United Arab Emirates, Dubai

This Limited Warranty does not apply if the fault has been caused by misuse, improper 

handling care, electrical or mechanical abuse, abnormal operating conditions or non-

E

xtron authorized modification to the product.

If it has been determined that the product is defective, please call Extron and ask for an 

Applications Engineer at (714) 491-1500  (USA), 31.33.453.4040 (Europe), 65.6383.4400 

(Asia), or 81.3.3511.7655 (Japan) to receive an RA# (Return Authorization number).  This 

will begin the repair process as quickly as possible. 

Units must be returned insured, with shipping charges prepaid.  If not insured, you 

assume the risk of loss or damage during shipment.  Returned units must include the 

serial number and a description of the problem, as well as the name of the person to 

contact in case there are any questions. 

E

xtron

 

Electronics makes no further warranties either expressed or implied with respect 

to the product and its quality, performance, merchantability, or fitness for any particular 

use.  In no event will Extron Electronics be liable for direct, indirect, or consequential 

damages resulting from any defect in this product even if Extron Electronics has been 

advised of such damage.
Please note that laws vary from state to state and country to country, and that some 

provisions of this warranty may not apply to you.

Summary of Contents for MMX 42 Series

Page 1: ...e Europe Only 31 33 453 4040 31 33 453 4050 FAX Extron Asia 800 7339 8766 Inside Asia Only 65 6383 4400 65 6383 4664 FAX Extron Japan 81 3 3511 7655 81 3 3511 7656 FAX Extron China 400 883 1568 Inside China Only 86 21 3760 1568 86 21 3760 1566 FAX Extron Middle East 971 4 2991800 971 4 2991880 FAX 2009 Extron Electronics All rights reserved User s Manual 68 778 01 Rev C 10 09 MMX 42 62 Series Comp...

Page 2: ... Netz zu trennen sollten Sie alle Netzkabel aus der Rückseite des Gerätes aus der externen Stomversorgung falls dies möglich ist oder aus der Wandsteckdose ziehen Schutz des Netzkabels Netzkabel sollten stets so verlegt werden daß sie nicht im Weg liegen und niemand darauf treten kann oder Objekte darauf oder unmittelbar dagegengestellt werden können Wartung Alle Wartungsmaßnahmen sollten nur von ...

Page 3: ...Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation The Class A limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates ...

Page 4: ...k mounting 2 2 UL guidelines 2 3 Mounting instructions 2 4 Under desk mounting 2 5 Rear Panel Cabling 2 6 Power connection 2 7 Video signal input connections 2 8 Video signal output connections 2 8 Audio signal input connections 2 8 Audio signal output connections 2 9 RS 232 connection 2 10 Chapter Three Operation 3 1 Front Panel Controls and Indicators 3 2 Front Panel Operations 3 3 Creating ties...

Page 5: ...tions 4 2 Switcher initiated messages 4 3 Error responses 4 3 Timeout 4 3 Using the command response table 4 4 Symbol definitions 4 4 Windows Based Program Control 4 7 Installing the software 4 7 Using the software 4 8 Input selection 4 8 Muting the video and audio signals 4 10 Setting audio levels 4 11 Front panel security lockout Executive mode 4 12 Updating the firmware 4 12 Windows menus 4 17 ...

Page 6: ...or audio inputs to either or both outputs Any input can be switched to either or both outputs The RCA models route unbalanced stereo audio and the AV and SVA models route balanced or unbalanced stereo audio The audio switching can either be linked with the video audio follow or independent of the video audio breakaway Adjustable audio gain and attenuation available via RS 232 control compensates f...

Page 7: ...t the inputs and outputs as well as audio follow or breakaway using the front panel buttons RS 232 control The operator can control the MMX 42 62 from a remote computer or other host using a link to the RS 232 port RS 232 control uses the Extron Simple Instruction Set SIS or the Windows based control software Simple Instruction Set The Simple Instruction Set lets a host computer control the MMX wi...

Page 8: ...604 21 RSU 126 6 inch deep universal rack shelf kit part 60 190 10 RSB 126 6 nch deep basic rack shelf part 60 604 11 RSU 129 9 5 inch deep universal rack shelf kit part 60 190 01 figure 2 2 on page 2 4 RSB 129 9 5 inch deep basic rack shelf part 60 604 02 2 4 40 x 3 16 Screws Use 2 mounting holes on opposite corners RSF 123 3 Rack Shelf Kit 1 2 Rack Width Front False Faceplate Figure 2 1 Mounting...

Page 9: ...shelf 3 Install false faceplate s or other unit s to the rack shelf Under desk mounting Mount the unit to a desk or podium using the optional MBU 123 under desk mounting kit part 70 212 01 as follows 1 If rubber feet were previously installed on the bottom of the unit remove them 2 Attach the mounting brackets to the switcher with the machine screws provided figure 2 3 3 Hold the unit with the bra...

Page 10: ... Figure 2 6 MMX 62 AV RCA rear panel 2 1 0 5A MAX 12V POWER OUTPUTS R L R L 2 1 3 4 1 2 INPUTS OUTPUTS MMX 42 SVA RCA TX RX RS 232 2 4 3 1 INPUTS 1 3 5 7 9 10 Figure 2 7 MMX 42 SVA RCA rear panel Power connection a Power connector Plug the external 12 V power supply into this 2 pole captive screw connector The power supply is included with the unit No damage will result if the power connector is w...

Page 11: ...ve Tip L Sleeve Gnd Tip L Ring R Sleeve Gnd Tip Sleeve Unbalanced mono Unbalanced stereo Tip signal Sleeve Gnd Figure 2 10 Phono audio connectors The audio level for each input can be individually set via RS 232 link to ensure that the level on the output does not vary from input to input See chapter 4 Remote Control for details g RCA audio connectors Connect unbalanced stereo audio inputs to thes...

Page 12: ...e MMX switcher via this 3 pole captive screw connector figure 2 13 for remote control using the SIS or Windows based control program DB9 Pinout Female To control equipment 5 1 9 6 Rx Tx Gnd Rx Tx Gnd RS 232 3 pole captive screw connector socket Pin RS 232 Function 1 2 TX Transmit data 3 RX Receive data 4 5 Gnd Signal ground 6 7 8 9 Figure 2 13 Wiring the remote connector The RS 232 protocol of the...

Page 13: ...d audio are selected for display the Audio LED blinks Front Panel Operations Plug in all system components and turn on the input devices such as DVD players and DSS receivers and the output devices Set the input devices to output video using each device s own operating instructions Creating ties A Tie is an input to output connection An input can be tied to both outputs An output can never be tied...

Page 14: ...tween genlocked sources Without the external sync locking feature switching between inputs can result in a brief rolling sync loss or a brief change in the picture size System Reset To reset the unit to factory defaults press and hold the Config button while power is applied This resets the audio input settings to unity 0 dB and connects input 1 to outputs 1 and 2 audio and video The audio and vid...

Page 15: ...is one or more characters Switcher initiated messages When a local event such as a front panel operation or error condition occurs the switcher responds by sending a message to the host The switcher initiated messages are listed below c Copyright 2004 Extron Electronics MMX 42 or 62 Vx xx 60 nnn nn The switcher issues the copyright message and the input selected message when it first powers on Vx ...

Page 16: ...mmand response fields Command and response examples are shown throughout the table The ASCII to HEX conversion table below is for use with the command response table ASCII to HEX Conversion Table Space Symbol definitions CR LF carriage return line feed space X Input 01 through maximum X Input number for tie 00 through maximum Input 0 deselected output X Output number 01 or 02 X Gain attenuation va...

Page 17: ... output X audio is broken away View video output tie X InX Video output X tied to input X View audio output tie X InX Audio output X tied to input X Video mute commands Video mute X 1B VmtX 1 Mute output X video blank screen Video unmute X 0B VmtX 0 Unmute output X video Video mute X B X Output X video mute status is X 0 off 1 on Global video mute 1 B Vmt1 Mute all video outputs Global video unmut...

Page 18: ...dio level X G X Front panel lockout executive mode Lock front panel 1X Exe1 Lock front panel Unlock front panel 0X Exe0 Unlock front panel View front panel lock status X X Show lock status 0 unlocked 1 locked Reset commands Reset all audio levels to 0 dB EZA Zpa Reseat all audio levels to 0 dB Unmute all video outputs EZB Zpb Unmute all video outputs Unmute all audio outputs EZZ Zpz Unmute all aud...

Page 19: ... is compatible with Windows 2000 and Windows XP Installing the software The program is contained on the Extron Software Products DVD Install the software as follows 1 Insert the DVD into the drive The Extron software DVD window figure 4 2 should appear automatically Figure 4 2 Software DVD window N If the window does not self start run Launch exe from the DVD 2 Click the Software tab figure 4 2 3 ...

Page 20: ...ection window 3 The Extron Universal Switcher Control Program window figure 4 5 displays the current ties In figure 4 5 indicates that the video input is selected indicates that the audio input is selected indicates that the input is not selected Figure 4 5 Universal Switcher Control program window Input selection See figure 4 5 The top row of inputs is available for output 1 and the bottom row of...

Page 21: ...it the front panel Input LED for the input tied to that output is off N If an output is muted any tie made from the front panel to that output unmutes it N You can also mute all inputs effectively muting the output by clicking the Mute All check box Setting audio levels To set or changes the levels for audio inputs 1 Place the mouse cursor over the Gain Attenuation tab at the side of the window Th...

Page 22: ...re made available on the Extron Web site www extron com The Firmware Loader software is also available from the Extron site Use the SIS Q command to determine the switcher s current firmware level Downloading the firmware from the Web site To obtain the latest version of firmware for your MMX switcher 1 Visit the Extron Web site www extron com click the Download tab then click the Firmware link on...

Page 23: ...install the Firmware Loader on your computer Unless you specify otherwise the installer program places the Firmware Loader file FWLoader exe in C Program Files Extron FWLoader N If the Extron and FWLoader folders do not yet exist in your Program Files folder the installer creates them 2 In the Universal Switcher Control Program click the tool bar s Firmware Loader button N If the Firmware Loader b...

Page 24: ...ware Loader Windows menus File menu Save Communications Log Opens a Save Log window that allows you to save all SIS commands from the current session to a text txt file Print Preview Communications Log Opens a window that presents a preview of a printed log of all SIS commands from the current session Print Communications Log Prints all SIS commands from the current session Exit Closes the Univers...

Page 25: ... video and audio ties and all video and audio mutes in the window This selection is also available via the tool bar s Refresh button Front Panel Lock Locks or unlocks all Input buttons and the Configuration button See Front panel security lockout Executive mode This selection is also available via the tool bar s Lock button Firmware Loader Calls the Extron Firmware Loader utility if installed on t...

Page 26: ...imum levels Analog 0 5 V to 2 0 Vp p with no offset Impedance 75 ohms Return loss 30 dB 5 MHz DC offset max allowable 1 5 V Video output Number signal type MMX 42 and MMX 62 composite video models 2 composite video MMX 42 SVA 2 S video Connectors MMX 42 and MMX 62 composite video models 2 female BNC MMX 42 SVA 2 female 4 pin mini DIN Nominal level 1 Vp p for Y of S video and for composite video 0 ...

Page 27: ... unbalanced at 1 THD N Maximum level 600 ohm 15 dBm balanced or unbalanced at 1 THD N Control remote switcher Serial control port RS 232 female 3 5 mm captive screw connector 3 pole Baud rate and protocol 9600 baud 8 data bits 1 stop bit no parity Serial control pin configurations 1 TX 2 RX 3 GND Program control Extron control configuration program for Windows Extron Simple Instruction Set SIS Gen...

Page 28: ... RSU 126 6 inch deep universal rack shelf kit 60 190 10 RSB 126 6 inch deep basic rack shelf 60 604 11 RSU 129 9 5 inch deep 1U universal rack shelf kit 60 190 01 RSB 129 9 5 inch deep 1U basic rack shelf 60 604 02 MBU 123 Under desk mounting kit 70 212 01 Cables Extron MHR 2 SVM M cable is suitable for S video This cable is terminated with male 4 pin mini DIN connectors on both ends Cable Part nu...

Page 29: ...MMX 42 62 Series Reference Information Specifications Part Numbers Accessories cont d A 8 ...