Power Connection

Use the 2-pole, 3.5 mm captive screw power connector to connect a power supply (not 
provided). The MLA VC10 Plus can share a power supply with an Extron control processor. If 
you are using a third-party controller, the MLA VC10 Plus must be connected to the Extron 
external 12 VDC, 1 A power supply (part number 

70-775-01

), which must be purchased 

separately.

CAUTIONS:

 

  For proper start up, the MLA VC10 Plus must be completely powered 

off before connecting it to the 12 VDC power supply.

 

  Read the caution in the “Power Connections” section of the 

MLA VC10 Plus User Guide

 for important information about power 

supplies and sharing a power supply between the MLA VC10 Plus and 
the MLC 104 IP Plus.

Additional Setup and Configuration

Connecting the Relay (Optional)

By default, the relay is used for the auto mute 
function. The relay automatically triggers on 
whenever the volume level on the MLA is 0 (see the 

MLA VC10 Plus User Guide

 for more information 

about this function). For a third-party amplifier that 
has contact closure terminals, the relay can be used 
to mute the audio.
This example shows how to set up the relay with 
a TOA 900 Series amplifier. Connections to other 
amplifiers are similar but see the user guide for your 
amplifier for details.

1. 

Connect the ground (Gnd) of the TOA 900 Series 
amplifier to the common (C) pin of the MLA VC10 Plus.

2. 

Connect the Mute 1 and Mute 2 terminals of the TOA 900 to the Normally Open (NO) 
pin of the MLA VC10 Plus.

The relay can be used for other, general purpose control once the auto mute function has 
been disabled. One example is to place the amplifier in standby mode to conserve power 
when it is idle. See the 

MLA VC10 Plus User Guide

 for examples and instructions.

C   Common

REMT

VO

L

MUTE

1

MUTE

2

GN

D

RELAY

NO

NC

C

Extron MLA VC10 Plus

TOA 900 Series

Amplifier

Summary of Contents for MLA VC10 Plus

Page 1: ...ovides instructions for quick installation and configuration of the MLA VC10 Plus with Extron products or some common third party amplifiers Installation and service must be performed by experienced installers only For complete features functions and configuration instructions read the user guides that come with your control processor and amplifier and see the MLA VC10 Plus User Guide which is ava...

Page 2: ...xtron SI 26 Surface mount Speakers Installation Decide where the unit will be installed Read the Mounting section of the MLA VC10 Plus User Guide for mounting options NOTES The majority of amplifiers researched and tested by Extron work with the MLA VC10 Plus default settings as the unit is shipped with no further configuration needed To avoid picking up background noise in the cable use shielded ...

Page 3: ...VC10 Plus to the reference voltage terminal 5V on the amplifier 2 Connect the ground wire G from the MLA VC10 Plus to the ground terminal Gnd on the amplifier 3 Connect the control signal wire C from the MLA VC10 Plus to the control signal terminal Ch 1 on the amplifier Third party Amplifier Two pin Connection This example shows the MLA VC10 Plus connected to a TOA 900 Series amplifier 1 Connect t...

Page 4: ...the commands shown below to the MLA VC10 Plus without needing to enter them manually For example this will allow you to exercise serial control over the MLA VC10 Plus volume by turning a knob on an MLC Using the driver requires the control processor to be configured with the appropriate Extron configuration software see the user guide for the control processor and the help file for the software Se...

Page 5: ...e auto mute function The relay automatically triggers on whenever the volume level on the MLA is 0 see the MLA VC10 Plus User Guide for more information about this function For a third party amplifier that has contact closure terminals the relay can be used to mute the audio This example shows how to set up the relay with a TOA 900 Series amplifier Connections to other amplifiers are similar but s...

Page 6: ...r amplifiers it may be necessary to set the maximum voltage output For example to set the voltage to 7 5 V using the following command EV 7 50VLCM NOTE You must include the final 0 in 7 50 The leading 0 07 50 is optional 5 Disconnect the USB connection to the computer 6 Connect the MLA VC10 Plus variable voltage ports to the amplifier z z Connect the ground G terminal of the MLA VC10 Plus to the g...