User's Manual
SENTOSA
xi
L
INE
Q
UADRUPLER
LANCIA
D
OUBLER
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201Fax 07131 911203
[email protected]
Page 1: ...User s Manual SENTOSAxi xi xi xi xi LINE QUADRUPLER LANCIAxi xi xi xi xi LINE DOUBLER im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131 911203 ce info camboard de...
Page 2: ...cci n aislante que puedan encontrarse dentro de la caja o alojamiento del producto y que puedan representar riesgo de electrocuci n Precauci n Para evitar riesgo de electrocuci n no extraer la tapa ni...
Page 3: ...ized by Extron Electronics Before calling Extron get the serial number of the unit in question a description of the problem and the name of the person to contact in case there are any questions This w...
Page 4: ...lectronics Europe Beeldschermweg 6C 3821 AH Amersfoort 31 33 453 4040 FAX 31 33 453 4050 The Netherlands Extron Electronics 1230 South Lewis Street Anaheim CA 92805 714 491 1500 FAX 714 491 1517 U S A...
Page 5: ...REMOTE Control Chapter 3 RS 232 Control 3 1 Host Sentosaxi Lanciaxi Communications 3 1 Using the Command Response Table 3 1 Command Response Table 3 2 Error Responses 3 3 Sentosaxi Lanciaxi Initiated...
Page 6: ...roceeding ___ A Warning possible damage could occur _ A Note a Hint or a Tip that may be helpful __ Possible Electrostatic Discharge ESD damage could result from touching electronic components __ Addi...
Page 7: ...ter One Introduction to Sentosaxi xi xi xi xi Lanciaxi xi xi xi xi Introduction Features Specifications Extron s SENTOSAxi LANCIAxi User s Manual im Vertrieb von CAMBOARD Electronics www camboard de T...
Page 8: ...tion an internal TBC Time Base Corrector actually cleans up low quality video tape signal noise common to VHS tape players for a more stable and sharper image Motion mode compensation virtually elimin...
Page 9: ...minate the jaggies found in line quadrupled or line doubled video Picture controls Picture controls include color hue tint horizontal shift and contrast for each input The Sentosaxi and Lanciaxi will...
Page 10: ...nput Sync output frequency Sentosaxi NTSC 3 58 4 43 63 kHz horizontal 60 Hz vertical PAL SECAM 62 5 kHz horizontal 50 Hz vertical DC offset 0 1 volt max Connectors 5 female BNCs Impedance 75 Ohms Gene...
Page 11: ...and Operation Rack Mounting Cabling Switch Settings DIP Switch Module Front and Rear Panels Operation Applications Extron s SENTOSAxi LQ and LANCIAxi LD User s Manual im Vertrieb von CAMBOARD Electron...
Page 12: ...saxi Lanciaxi is capable of switching between two inputs one composite and one S Video Therefore one of each video input type may be connected Connecting the Input Output Cables 1 Connect the input de...
Page 13: ...ntosaxi Lanciaxi to a computer refer to the picture below and connect the user supplied RS 232 cable from the Host system device serial port to the Sentosaxi Lanciaxi connector labeled RS 232 ___ When...
Page 14: ...e bottom of this page Sentosaxi Rear Panel Lanciaxi Rear Panel Select the desired sync type using the H HV SOG toggle switch located between the H HV and V BNC connectors see rear panel drawings above...
Page 15: ...isabled The output will have twice the number of input horizontal lines per screen scan For NTSC the number of horizontal lines per screen scan normally 262 5 will double to 525 For the PAL system the...
Page 16: ...once when the control passes through the default value Rotation of a control will increase or decrease a decimal value which is stored in a nonvolatile memory The memory stores two sets of decimal val...
Page 17: ...osition of this switch determines horizontal and vertical sync output location Switch top H position H sync on H HV BNC V sync on V BNC Switch center HV position Composite HV sync on H HV BNC Switch b...
Page 18: ...ble the original number of horizontal lines For NTSC 3 58 NTSC 4 43 video each field of 262 5 lines is doubled to create a 525 line non interlaced screen scan The same process applies to PAL SECAM vid...
Page 19: ...Lanciaxi provided by an SW 6 AV MX switcher Application with one input to the Sentosaxi or Lanciaxi provided by a MAV 62 switcher Application with one input to the Sentosaxi or Lanciaxi provided by a...
Page 20: ...m a System 8 10 PLUS Switcher as the input to a Sentosaxi LQ or a Lanciaxi LD The output of the Sentosaxi Lanciaxi is connected back to the last input input 8 or 10 of the System 8 10 PLUS Switcher Th...
Page 21: ...nual 3 Chapter Three RS 232 REMOTE Control RS 232 Control Windows Compatible Software Extron s SENTOSAxi LQ LANCIAxi LD User s Manual im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911...
Page 22: ...oard Simple commands could be from a terminal or any other Host device When the Sentosaxi Lanciaxi receives a command and determines that it is valid it will execute the command and send a response ba...
Page 23: ...60 229 01 Sentosa q 71h Same as Q below Query software version q QVER 1 23 1 23 is example only Q 51h QVER Query software version Q QVER 1 23 Software version 1 23 C h 43h Col Set color value Col to...
Page 24: ...elow underlined to identify actual message C Copyright 1998 Extron Electronics Model V x xx This message is initiated by the Sentosaxi Lanciaxi when it is first powered on Model Sentosaxi or Lanciaxi...
Page 25: ...allation will create by default a C LANCIA directory and will place 2 icons LANCIA SENTOSA Control Program and LANCIA SENTOSA Help into a group titled Extron Electronics Using the Software 1 For infor...
Page 26: ...input with a logic low 0 volts the Tally pins are normally at logic high 5 volts The schematics shown below may be used as a guide to design and build indicator circuits for the Tally pins Since ther...
Page 27: ...Other Reference Material Remote Contact Closure Operation Accessories and Part Numbers Limited Warranty Extron s SENTOSAxi LQ LANCIAxi LD User s Manual im Vertrieb von CAMBOARD Electronics www camboar...
Page 28: ...C 5 100 HR 100 feet 30 0 meters 26 260 05 BNC 5 150 HR 150 feet 45 0 meters 26 260 12 BNC 5 200 HR 200 feet 60 0 meters 26 260 06 BNC 5 250 HR 250 feet 75 0 meters 26 260 18 BNC 5 300 HR 300 feet 90 0...