Channels 

 
The main program controls the switcher via channel events (NetLinx commands 

pulse, on, and off

) sent to 

the COMM module. The channels supported by the COMM module are listed below. These channels are 
associated with the virtual device and is independent of the channels associated with the touch panel 
device. 
 
Note: An ‘*’ indicates an extension to the standard API. 

Channel 

Description 

24 

PULSE: Ramp Volume Up 1db 

25 

PULSE: Ramp Volume Down 1db 

26 

PULSE: Cycle Volume Mute 

199 

ON: Set Volume Mute On – used for feedback also 
OFF: Set Volume Mute Off 

251 

ON: Device is Online – used for feedback only 
OFF: Device is not Online 

Table 2 - Virtual Device Channel Events 

Levels 

 
The main program controls the switcher via level events (NetLinx command 

send_level

) sent to the 

COMM module. The level supported by the COMM module is listed below. This level is associated with 
the virtual device and is independent of the levels associated with the touch panel device. 
 
Note: An ‘*’ indicates an extension to the standard API. 

Level 

Description 

Volume Level (range 0…255) 

Table 3 - Virtual Device Level Events 

Summary of Contents for IN1508

Page 1: ...Professional Control Solutions LLC 3804 Parchment Circle Richmond VA 23233 7034 804 364 3809 PCS_LLC comcast net NetLinx Module Interface Specification for Extron IN1508 Switcher Scaler...

Page 2: ...on 3 Overview 3 Implementation 3 Port Mapping 4 Channels 5 Levels 5 Command Control 6 Command Feedback 7 Device Notes 7 Programming Notes 7 Adding Functions to Modules 8 Commands to the device 8 Respo...

Page 3: ...erview The COMM module translates between the standard interface described below and the switcher serial protocol It parses the buffer for responses from the switcher sends strings to control the swit...

Page 4: ...ation the device ID of the switcher to be controlled and the virtual device ID for communicating to the main program For an example of how to do this see below DEFINE_DEVICE dvSwt 5001 1 0 serial cont...

Page 5: ...ion 24 PULSE Ramp Volume Up 1db 25 PULSE Ramp Volume Down 1db 26 PULSE Cycle Volume Mute 199 ON Set Volume Mute On used for feedback also OFF Set Volume Mute Off 251 ON Device is Online used for feedb...

Page 6: ...gramming Notes section value 0 set all messages off 1 set all messages on DEBUG 1 PASSTHRU string Allows user the capability of sending commands directly to whatever unit is attached with minimal proc...

Page 7: ...ll messages off 1 set all messages on DEBUG 1 SWITCH input Reports the input channel that is currently connected to the output channel This string is sent in response to the CL command being successfu...

Page 8: ...e module will automatically generate the checksum In this case the following string should be sent from the UI code to implement white balance adjustment send_command vdvDevice PASSTHRU 03 10 05 14 Th...

Reviews: