Underwriters Laboratories Guidelines for Rack Mounting

The following Underwriters Laboratories (UL) guidelines are relevant to the safe 
installation of products in a rack:

Elevated operating ambient temperature —

 If a unit is installed in a closed or multi-unit 

rack assembly, the operating ambient temperature of the rack environment may be greater 
than room ambient temperature. Therefore, install the equipment in an environment 
compatible with the maximum ambient temperature specified by Extron.

Reduced air flow —

 Install the equipment in the rack so that the equipment gets adequate 

air flow for safe operation.

Mechanical loading —

 Mount the equipment in the rack so that uneven mechanical 

loading does not create a hazardous condition.

Circuit overloading —

 Connect the equipment to the supply circuit and consider the effect 

that circuit overloading might have on overcurrent protection and supply wiring. Give 
appropriate consideration to the equipment nameplate ratings when addressing this 
concern.

Reliable earthing (grounding) —

 Maintain reliable grounding of rack-mounted equipment. 

Pay particular attention to supply connections other than direct connections to the branch 
circuit (such as the use of power strips).

Secure Devices to the Shelf

TIP:

 

It is easier to secure devices to the shelf before attaching the shelf to the rack.

All rack-mountable Extron devices have two 
threaded holes in diagonally opposite corners of 
the base plate for mounting onto the shelf.

CAUTION:

  Some products have hexagonal 

holes in their base, which anchor 
stand-offs for internal circuit boards 
(see the figure to the right). Using these 
holes will damage the product and will 
not provide secure mounting. 

Before securing a device to the shelf, decide where it will be placed. If multiple smaller 
devices are to be placed on a single shelf they can be placed at the front of the rack or the 
back. Ensure that adequate space remains for running cables.
To mount the device to the shelf, follow these instructions and see figure 2 on the opposite 
page:

1. 

If the device has rubber feet attached, remove them.

2. 

Place the device on the rack so that the rack mounting holes are aligned with two holes 
in the rack.

3. 

Secure the device to the shelf, using two of the provided 4-40 x 3/16 inch screws.

4. 

Repeat steps 

1

 to 

3

 to install other devices, as desired.

#4-40 Thread for
Rack Mounting

Hexagonal Stand-off
(for mounting
circuit board)

2