HAE 100 4K Plus • SIS Commands
9
Using the Command and Response Table
The Command and Response Table
below shows SIS commands for the HAE 100 4K Plus.
Command and response examples are shown throughout the table. Symbols are used throughout
the table to represent variables in the command and response fields. Use the ASCII to HEX
Conversion Table with the Command and Response Table.
ASCII to HEX Conversion Table
Space
.
Command and Response Table for SIS Commands
Command
ASCII
Command
(host to unit)
Response (unit to host)
Additional Description
Signal status
Input/Output Signal Status
E
0
LS
}
X#
•
X#]
Sig
X#
•
X#]
Input•Output
Verbose mode 2/3
Input HDCP Status
E
IHDCP
}
X1@]
HdcpI
X1@]
Verbose mode 2/3
Output HDCP Status
E
OHDCP
}
X1#]
HdcpO
X1#]
Verbose mode 2/3
Input Audio Status
1S
X!]
AudI
X!]
Verbose mode 2/3
EDID Minder
View EDID in HEX format
E
REDID
}
X&]
HEX data from currently assigned
EDID
View EDID Native Rate
E
NEDID
}
X*]
Example:
KEY:
X!
= Input audio status:
0
= No audio detected or detected audio cannot be de-embedded
1
= S/PDIF Bitstream audio detected 2 = 2-Ch LPCM detected
X#
=
0
= off, disabled or not detected
1
= on, enabled, or detected
X&
= 128 or 256 Byte EDID raw HEX (text form) from currently assigned EDID
X*
= Native resolution and refresh rate from currently assigned EDID (Ex:
1920x1080 @60 Hz
)
X1@
= Input HDCP status:
0
= No active video source detected
1
= Video detected without HDCP (not encrypted)
2
= Video detected with HDCP (encrypted)
X1#
= Output HDCP status:
0
= No sink detected
1
= Non-HDCP sink detected (sink is not HDCP compliant)
2
= HDCP sink detected not encrypted
3
= HDCP sink detected and encrypted