background image

 

4

EBP 1200C • Setup Guide (Continued)

Mounting the EBP 1200C

A variety of modules allow you to populate the Cable Cubby enclosure with a combination of AAPs, cable pass-through, 
retractors, or power modules. The EBP 1200C accommodates your choice of any two modules, allowing you to customize the 
device to meet your specific needs.

Assemble the Connectivity Modules of your Choice

The EBP 1200C is provided with a single connectivity bracket that can be used with either the AAP frame plate or the cable 
grommet plate. Follow the steps below to assemble the connectivity modules of your choice before they can be mounted into the 
EBP 1200C.

AAP module

The AAP module accommodates up to three single-space AAPs.

Secure up to three single-space 

AAPs in the AAP plate.

Secure the AAP plate on the connectivity brackets, 

using four of the provided module screws.

#4-40 Nut with 

Captive Washer

Insert cables through the bottom of the connectivity bracket. 

Connect cables to the AAPs.

1

3

2

Secure the grommet plate on the 

connectivity bracket, using four 

of the provided module screws.

2

Insert cables through the bottom of 

the connectivity bracket and into the 

holes of the grommet plate.

You may need to bend the

plate gently to slide the cable

past the slot opening.

Snap the included 

hole plugs into any 

unused holes.

1

3

Figure 3. 

Assembling the AAP Module

NOTE:

  After assembling the AAP module, proceed to 

Install the Modules

 below.

Cable pass-through module

The cable pass-through module accommodates up to eight AV cables.

 

Secure up to three single-space 

AAPs in the AAP plate.

Secure the AAP plate on the connectivity brackets, 

using four of the provided module screws.

#4-40 Nut with 

Captive Washer

Insert cables through the bottom of the connectivity bracket. 

Connect cables to the AAPs.

1

3

2

Secure the grommet plate on the 

connectivity bracket, using four 

of the provided module screws.

2

Insert cables through the bottom of 

the connectivity bracket and into the 

holes of the grommet plate.

You may need to bend the

plate gently to slide the cable

past the slot opening.

Snap the included 

hole plugs into any 

unused holes.

1

3

Figure 4. 

Assembling the Cable Pass-through Module

Install the Modules

Determine where the modules are installed in the Cable Cubby. Any combination of two modules can be installed. The modules 
can be installed on either side of the enclosure and at various heights.

NOTES:

 

• 

Ensure that there is enough room above the modules for the Cable Cubby lid to close completely.

• 

Use a screwdriver to secure the modules with the screws.

Summary of Contents for EBP 1200C

Page 1: ...t RS 232 VGA Figure 1 EBP 1200C Application Diagram Setup Checklist Step 1 Planning Download and install the latest version of the software firmware and device drivers needed to configure the IPCP Pro...

Page 2: ...F e ON OFF PC LAPTOP MUTE AUX VIDEO VGA HDMI Item Qty Item Qty Item Qty 1 EBP 1200C 1 6 Retractor Pin and Clip 1 9 4 40 Module Screws 8 2 Connectivity Bracket 1 7 Hole Plugs 6 3 8 2 1 4 3 AAP Frame Pl...

Page 3: ...particuli rement attention la directions dans laquelle l unit sera dirig e Le c t pour acc der au connecteurs est soulign voir CNC Wood Router ci dessous Extron ne sera pas responsable des erreurs de...

Page 4: ...plate You may need to bend the plate gently to slide the cable past the slot opening Snap the included hole plugs into any unused holes 1 3 Figure 3 Assembling the AAP Module NOTE After assembling the...

Page 5: ...OFF PC LAPTOP MUTE AUX VIDEO VGA HDMI e 21 5 25 0 1LF The bracket may be installed on the left or right side of the enclosure and at the lowest height 2 1 Figure 5 Install the Retractor Bracket AAP m...

Page 6: ...move the plastic strips and film on the surface of the Cable Cubby Ensure that the side clamps are seated against the enclosure Lower the Cable Cubby into the hole to test the fit If necessary careful...

Page 7: ...o not overtighten 2 3 1 4 Figure 9 Installing Retractors Horizontal Mounting Remove two enclosure screws one on each side from this position Then mount the Retractors as shown at left Cable Release As...

Page 8: ...MUTE button to the right E Button panel removal slots Use the Extron removal tool in these slots to release the top of the panel when replacing buttons F Input and function buttons If these buttons a...

Page 9: ...ons without the panel becoming completely detached You can now return the lid to the fully open position 5 5 From the front of the panel press the button until it is free of the panel 6 6 From the bac...

Page 10: ...he diagrams in this section as a guide NOTES By factory default the EBP 1200C is set to address 26 binary 011010 as shown in the diagram below Any address can be used except address 0 binary 000000 Th...

Page 11: ...er an EBP from more than one power source ATTENTION Always use a power supply supplied or specified by Extron Use of an unauthorized power supply voids all regulatory compliance certification and may...

Page 12: ...1200C eBUS 24 WATTS MAX 100 240V 50 60Hz 0 6A MAX S V S G S V S G S V S G S V S G S V S G S V S G RESET eBUS Status ON M S B BUS ID 1 2 3 4 5 6 V LINK COM ERROR ID ERROR S S S G V S G L S B PWR LOAD 2...

Page 13: ...een set up you can use Global Scripter to program buttons and LEDs Test and Troubleshoot 1 Verify that the DIP switches on the EBPs are set to the desired address on each unit and that there are no DI...

Page 14: ...ia 65 6383 4400 65 6383 4664 FAX Extron Japan 81 3 3511 7655 81 3 3511 7656 FAX Extron China 86 21 3760 1568 86 21 3760 1566 FAX Extron Middle East 971 4 299 1800 971 4 299 1880 FAX Extron Australia 6...