DXP HD 4K PLUS Series • SIS Configuration and Control
35
SIS Configuration
and Control
The DXP HD 4K PLUS Series can be configured and controlled with Extron Simple
Instruction Set commands. This section describes the communication between a connected
host computer or other control device (such as a control system) and the device. Topics
include:
•
•
Host and Matrix Switcher Communication
•
•
Command and Response Table for SIS Commands
Connection Methods
Attach the host device to one of the following connectors:
•
E
, on page 6)
•
,
F
)
•
USB connector (see
figure 6
,
A
, on page 13)
Commands can be entered using a Telnet application such as the Extron DataViewer,
available at
DataViewer Help
file for more details).
Host and Matrix Switcher Communication
SIS commands consist of one or more characters per field. No special characters are
required to begin or end a command sequence. Commands can be entered
back-to-back in a string with no spaces. When the switcher determines that a command
is valid, it executes the command and sends a response to the host device. All responses
from the switcher to the host end with a carriage return and a line feed (CR/LF =
]
),
indicating the end of the response character string (one or more characters).
Copyright Information
The copyright message is displayed upon connecting to a switcher via TCP/IP or Telnet or
after a power cycle via RS-232, and depends on the matrix switcher model.
(c)
Copyright
20
nn
,
Extron
Electronics,
DXP
nn
HD
4K
Plus,
V
n.nn
,
60-1495-
nn
]
Ddd
,
DD
Mmm
YYYY
HH
:
MM
:
SS
]
20nn
is the year.
DXP
nn
HD 4K Plus
is the model name.
V
n.nn
is the firmware version number.
60-1495-
nn
is the model part number.
(Day, date, and time as in Mon, 12 Feb 2018 11:27:33)