Under-desk mounting

Mount the unit under a desk or podium using the optional 
Extron MBU 125 under desk mounting kit (part #

70-077-01

) as 

follows:

1

If rubber feet were previously installed on the bottom of 
the unit, remove them.

2

Attach the mounting brackets to the interface with the 
machine screws provided (fi gure 2-3).

 

Figure 2-3 — Under-desk mounting the interface

3

Hold the unit with the brackets attached against the 
underside of the table or other furniture.  Mark the location 
of the screw holes of the bracket on the mounting surface.

4

Drill four pilot holes, each 3/32" (2 mm) in diameter by 
1/4" deep (6.3 mm) deep in the mounting surface at the 
marked screw locations.

5

Insert #8 wood screws into the four pilot holes.  Tighten 
each screw into the mounting surface until just less than 
1/4" (6.3 mm) of the screw head protrudes.

6

Align the mounting screws with the slots in the brackets 
and place the unit against the surface, with the screws 
through the bracket slots.

7

Slide the unit slightly in or out, then tighten all four screws 
to secure the unit in place (fi gure 2-3).

Through-desk mounting

Mount the unit through a desk or podium using the optional 
Extron MBD 129 through desk mounting kit (part #

70-077-02

) as 

follows:

1

If rubber feet were previously installed on the bottom of 
the unit, remove them.

2

Secure the brackets to the interface with the provided 
machine screws (fi gure 2-4).  Leave the screws slightly loose.

 

Figure 2-4 — Through-desk mounting the interface

3

Hold the interface and brackets on the underside of the 
surface to which you are mounting the device and mark 
the four screw holes and the table material to be removed.

4

Remove the table material.  Test the fi t by inserting the 
front of the device through the hole.  If necessary, use a 
rasp or coarse fi le to enlarge the hole.

5

Drill four pilot holes, each 3/32" (2 mm) in diameter by 
1/4" deep (6.3 mm) deep , as marked on the template.

6

Using the four wood screws provided, attach the brackets 
to the mounting surface.

Summary of Contents for DVI-RGB 150

Page 1: ...31 33 453 4050 Extron Electronics Asia 135 Joo Seng Road 04 01 PM Industrial Building Singapore 368363 65 6383 4400 Fax 65 6383 4664 Extron Electronics Japan Kyodo Building 16 Ichibancho Chiyoda ku T...

Page 2: ...sma nahmen sollten nur von qualifiziertem Servicepersonal durchgef hrt werden Die internen Komponenten des Ger tes sind wartungsfrei Zur Vermeidung eines elektrischen Schocks versuchen Sie in keinem F...

Page 3: ......

Page 4: ...Tabletop placement 2 2 Rack mounting 2 2 Under desk mounting 2 4 Through desk mounting 2 5 Rear Panel Connections and Controls 2 6 Front Panel Controls and Indicator 2 8 Operation 2 9 DVI Connector P...

Page 5: ...DVI RGB 150 Table of Contents Table of Contents cont d DVI RGB 150 1 Chapter One Introduction All trademarks mentioned in this manual are the properties of their respective owners 68 1247 01 Rev A 07...

Page 6: ...OP THR OU GH R H G V B S SOG ON OFF SPARE DD C SO UR CE MO NIT OR SEL ECT OR OU TPU T RE SO L Extron DVI RGB 150 Figure 1 1 Typical DVI RGB 150 application The video source uses the bidirectional Dis...

Page 7: ...place it in any convenient location Rack mounting For optional rack mounting mount the interface on any of the following rack shelves RSU 126 6 1U deep universal rack shelf kit part 60 190 10 figure 2...

Page 8: ...lign the mounting screws with the slots in the brackets and place the unit against the surface with the screws through the bracket slots 7 Slide the unit slightly in or out then tighten all four screw...

Page 9: ...r up position to connect the DDC channel between the direct digital video source and the local monitor Set this switch to the Selector down position to connect the DDC channel between the direct digit...

Page 10: ...RGB output Increased peaking can compensate for detail mid and high frequency loss from low bandwidth system components or capacitance in long cables The minimum setting at the counterclockwise limit...

Page 11: ...of adapters Use only approved DVI connectors C Use only cables specifically intended for DVI interfaces Use of non DVI cables or modified cables can cause the DVI RGB 150 to fail N The missing connect...

Page 12: ...Level adjustment range 0 dB to 6 dB x1 to x2 Peaking adjustment range 0 dB to 6 dB x1 to x2 at 100 MHz Impedance 75 ohms Output resolution Follows input determined by the local DVI loop through monit...

Page 13: ...al Safe Transit Association Listings UL CUL Compliances CE FCC Class A VCCI AS NZS ICES MTBF 30 000 hours Warranty 3 years parts and labor N All nominal levels are at 10 N Specifications are subject t...

Page 14: ...DVI RGB 150 Reference Information Reference Information A 6...

Reviews: