background image

6. 

Connect an RJ‑45 DTP or HDBT receiving device

 to the output (see 

figure 2

E

 on the previous 

page) for either 

DTP

 or 

HDBT

 mode (see image to the right to properly wire the RJ-45 connector).

• 

If the receiver is in the 

Extron DTP2 series

, set the 

DTP/HDBT toggle switch

 (

F

) to 

DTP 

and

 

the 

SEND POWER switch

 (

H

) to the 

UP (SEND POWER)

 position. 

On the receiver, set the  

SEND POWER switch to the DOWN (OFF) position.

• 

If the receiver is in the E

xtron Legacy DTP series

, set the 

DTP/HDBT toggle switch

 (

F

) to  

DTP

 and the 

SEND POWER switch

 (

H

) to the 

DOWN (OFF)

 position.

• 

If the receiver is 

HDBaseT enabled

, set the 

DTP/HDBT toggle switch

 (

F

) to 

HDBT

, and the 

SEND POWER switch

 (

H

) to the 

DOWN (OFF)

 position.

ATTENTION:

• 

Position these toggle switches (see 

figure 2

,

 

F

 

and 

H

)

 

BEFORE

 connecting the appropriate device to the TP 

connector. Failure to comply can damage the endpoint.

• 

Positionnez ces sélecteurs (voir 

figure 2

F

 et 

H

AVANT

 de connecter l’appareil approprié au connecteur TP. Ne pas 

respecter cette procédure pourrait endommager le point de connexion.

• 

The DTP2 T 212 is configured to output power to 

DTP2 models

 only. If connected to a 

Legacy DTP or HDBT device

, set 

the SEND POWER toggle switch to the “DOWN” position (OFF). Failure to turn the power OFF will damage the connected 
Legacy DTP device.

• 

Le DTP2 T 212 est configuré pour fournir une alimentation aux modèles DTP2 uniquement. S’il est connecté à un autre 
appareil, veuillez positionner l’interrupteur à bascule sur « DOWN » (OFF). Si l’interrupteur n’est pas positionné sur OFF, 
vous risquez d’entraîner la défaillance de l’appareil Legacy DTP connecté.

NOTE:

 

When the output is configured for 

DTP

 

mode

, remote power is available for Extron 

DTP2

 devices only. When the 

output is configured for 

HDBT

 

mode

, remote power is disabled and both the switching transmitter and receiver require their 

own 12 VDC power supply.

DTP2 R 211

CONFIG

INPUT
LINK
OUTPUT

SEND

POWER

OFF

STATUS

SEND

POWER

OFF

SEND

POWER

OFF

DTP2 R 211

CONFIG

INPUT
LINK
OUTPUT

SEND

POWER

OFF

STATUS

SEND

POWER

OFF

SEND

POWER

OFF

SEND

POWER

OFF

DTP HDMI 330 Rx

OVER DTP

RS-232

IR

Tx Rx

Tx Rx

G

OFF

OFF

ON

ON

OFF

Rx G

Tx

RS-232

IR

Rx

Tx

OVER TP

POWER

12V   
2.0A MAX

RS-232

CONTACT /

TALLY

1

C G T

C G

G

Rx

Tx

+V

T

2

1

AUDIO

2

A

B

REMOTE

INPUTS

OUTPUT

S

SIG                 LINK

OUT

DTP

HDBT

OFF

SEND

POWER

Rx G

Tx

RS-232

IR

Rx

Tx

OVER TP

POWER

12V   
2.0A MAX

RS-232

CONTACT /

TALLY

1

C G T

C G

G

Rx

Tx

+V

T

2

1

AUDIO

2

A

B

REMOTE

INPUTS

OUTPUT

S

SIG                 LINK

OUT

DTP

HDBT

OFF

SEND

POWER

Rx G

Tx

RS-232

IR

Rx

Tx

OVER TP

POWER

12V   
2.0A MAX

RS-232

CONTACT /

TALLY

1

C G T

C G

G

Rx

Tx

+V

T

2

1

AUDIO

2

A

B

REMOTE

INPUTS

OUTPUT

S

SIG                 LINK

OUT

DTP

HDBT

OFF

SEND

POWER

Local

Power Supply

CATx Cable

up to 330' (100 m) 

Local

Power Supply

No Remote Power

Extron 

DTP2 T 212

Transmitter

Extron 

DTP HDMI 4K 330 Rx

Receiver

DTP Endpoint Connected to a DTP2 Endpoint

CATx Cable

up to 330' (100 m) 

Direction of

Remote Power

Local

Power Supply

Extron 

DTP2 T 212

Transmitter

Extron 

DTP2 R 211

Receiver

CATx Cable

up to 330' (100 m) 

Direction of

Remote Power

Extron 

DTP2 T 212

Transmitter

Extron 

DTP2 R 211

Receiver

DTP2 Endpoint Connected to a DTP2 Endpoint

Local

Power Supply

DTP2 R 211

CONFIG

INPUT
LINK
OUTPUT

SEND

POWER

OFF

STATUS

SEND

POWER

OFF

SEND

POWER

OFF

DTP2 R 211

CONFIG

INPUT
LINK
OUTPUT

SEND

POWER

OFF

STATUS

SEND

POWER

OFF

SEND

POWER

OFF

SEND

POWER

OFF

DTP HDMI 330 Rx

OVER DTP

RS-232

IR

Tx Rx

Tx Rx

G

OFF

OFF

ON

ON

OFF

Rx G

Tx

RS-232

IR

Rx

Tx

OVER TP

POWER

12V   
2.0A MAX

RS-232

CONTACT /

TALLY

1

C G T

C G

G

Rx

Tx

+V

T

2

1

AUDIO

2

A

B

REMOTE

INPUTS

OUTPUT

S

SIG                 LINK

OUT

DTP

HDBT

OFF

SEND

POWER

Rx G

Tx

RS-232

IR

Rx

Tx

OVER TP

POWER

12V   
2.0A MAX

RS-232

CONTACT /

TALLY

1

C G T

C G

G

Rx

Tx

+V

T

2

1

AUDIO

2

A

B

REMOTE

INPUTS

OUTPUT

S

SIG                 LINK

OUT

DTP

HDBT

OFF

SEND

POWER

Rx G

Tx

RS-232

IR

Rx

Tx

OVER TP

POWER

12V   
2.0A MAX

RS-232

CONTACT /

TALLY

1

C G T

C G

G

Rx

Tx

+V

T

2

1

AUDIO

2

A

B

REMOTE

INPUTS

OUTPUT

S

SIG                 LINK

OUT

DTP

HDBT

OFF

SEND

POWER

Local

Power Supply

CATx Cable

up to 330' (100 m) 

Local

Power Supply

No Remote Power

Extron 

DTP2 T 212

Transmitter

Extron 

DTP HDMI 4K 330 Rx

Receiver

DTP Endpoint Connected to a DTP2 Endpoint

CATx Cable

up to 330' (100 m) 

Direction of

Remote Power

Local

Power Supply

Extron 

DTP2 T 212

Transmitter

Extron 

DTP2 R 211

Receiver

CATx Cable

up to 330' (100 m) 

Direction of

Remote Power

Extron 

DTP2 T 212

Transmitter

Extron 

DTP2 R 211

Receiver

DTP2 Endpoint Connected to a DTP2 Endpoint

Local

Power Supply

Figure 3. 

Send Power Toggle Switch Configuration

7. 

Connect Over TP RS‑232 and IR control. 

Connect a serial RS-232 signal, a modulated 

IR signal, or both into this 3.5

 mm, 5-pole captive screw port (

G

) for IR and bidirectional 

RS-232 communication (see wiring diagram on the right).

 

5

Pin

1

2
3

6
7
8

4

Wire color

White-green

Green

White-orange

White-blue

Orange

White-brown

Brown

Blue

TIA/EIA T

568B

TP Wires

12345678

Pins:

Rx Tx

Tx Rx

Gnd

Gnd

IR Device

RS-232 Device

OVER TP RS-232/IR

RS-232

O

VE

TP

IR

 

Tx

Rx

Tx

Rx

G

Tx/Rx

Pins

 

DTP2 T 212 • Setup Guide (Continued)

2

Reviews: